Perspectives on Liquid Chromatography-High-Resolution Mass Spectrometry for Pesticide Screening in Foods.

J Agric Food Chem

Thermo Fisher Scientific , 355 River Oaks Parkway , San Jose , California 95134 , United States.

Published: September 2018


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This perspective discusses the use of liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS) for multiresidue analysis of pesticides in foods and agricultural commodities. HRMS has the important distinction and advantage of mass-resolving power and, therefore, requires different concepts, experiments, and guidance for screening, identification, and quantitation of pesticides in complex food matrices over triple quadrupole mass spectrometry. HRMS approaches for pesticide screening, including full-scan experiments in conjunction with tandem mass spectrometry (MS/MS) experiments, are described. This approach results in the generation of chromatographic retention times and high-resolution mass spectra with accurate mass measurements that can be used to create compound databases. New data processing tools can create an efficient and optimized screening approach that can speed the analysis and identification of compounds, reduce the need for chemical standards, and harmonize pesticide analytical procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.jafc.8b03468DOI Listing

Publication Analysis

Top Keywords

mass spectrometry
16
pesticide screening
8
high-resolution mass
8
mass
6
perspectives liquid
4
liquid chromatography-high-resolution
4
chromatography-high-resolution mass
4
spectrometry
4
spectrometry pesticide
4
screening
4

Similar Publications

Background: Subcellular localisation is a determining factor of protein function. Mass spectrometry-based correlation profiling experiments facilitate the classification of protein subcellular localisation on a proteome-wide scale. In turn, static localisations can be compared across conditions to identify differential protein localisation events.

View Article and Find Full Text PDF

To evaluate the quality of pomegranate peels from different cultivars, pomegranate peel samples from 47 cultivars were compared and classified based on fingerprints and chemical components obtained using HPLC-PDA-MS/MS combined with chemometric methods. Three pattern recognition methods, namely, hierarchical cluster analysis, principal component analysis, and partial least square-discriminant analysis, were used to establish classification models. Results showed that the contents of 10 components from pomegranate peel were determined.

View Article and Find Full Text PDF

Objective: Osimertinib (OSI) therapy, a cornerstone in treating non-small cell lung cancer (NSCLC), has been severely limited by rapidly developing acquired resistance. Inhibition of bypass activation using a combination strategy holds promise in overcoming this resistance. Biguanides, with excellent anti-tumor effects, have recently attracted much attention for this potential.

View Article and Find Full Text PDF

Li-Well ZnO Memtransistors: High Reliability for Neuromorphic Applications.

Adv Mater

September 2025

Department of Materials Science & Engineering, Kyung Hee University, Yongin, 17104, Republic of Korea.

Memtransistors are active analog memory devices utilizing ionic memristive materials as channel layers. Since their introduction, the term "memtransistor" has widely been adopted for transistors exhibiting nonvolatile memory characteristics. Currently, memtransistor devices possessing both transistor on/off functionality and nonvolatile memory characteristics include ferroelectric field-effect transistors (FeFETs) and charge-trap flash (floating gate), yet ionic memtransistors have not matched their performance.

View Article and Find Full Text PDF

Background: This study investigates the impact of trimethylamine oxide (TMAO) on recurrent cerebral infarction in minor ischemic stroke (MIS).

Methods: A rat model was used, with dietary choline levels adjusted to vary TMAO levels. TMAO was quantified via liquid chromatography-mass spectrometry (LC-MS), and histological changes in brain and aortic tissues were analyzed using HE staining.

View Article and Find Full Text PDF