98%
921
2 minutes
20
A new concept of "dual-phase dual stir bar sorptive extraction (SBSE)" was proposed to simultaneously extract six preservatives with different polarities (logKo/w values of 1.27-3.41), namely, benzoic acid (BA), sorbic acid (SA), methyl p-hydroxybenzoate (MP), ethyl p-hydroxybenzoate (EP), propyl p-hydroxybenzoate (PP), and butyl p-hydroxybenzoate (BP). The dual-phase dual SBSE apparatus was consisted of two differently coated stir bars, a 3-aminopropyltriethoxysilane (APTES)-hydroxy-terminated silicone oil (OH-TSO)-coated stir bar that was prepared by sol-gel technique and a C(18) silica (C(18))-polydimethylsiloxane (PDMS)-coated stir bar that was prepared by adhesion. In dual-phase dual SBSE, the two stir bars with different coatings were placed in the same sample solution for the simultaneous extraction of the target analytes with different polarities, and then the bars were desorbed in the same desorption solvent. The extraction performance of the dual-phase dual SBSE for the six preservatives was evaluated by comparing with the conventional SBSE (individual stir bar) with different coatings, including commercial PDMS, homemade PDMS, C(18)-APTES-OH-TSO, APTES-OH-TSO, and C(18)-PDMS. The experimental results showed that the dual-phase dual SBSE had the highest extraction efficiency for the six target preservatives. Based on this fact, a novel method by combining the dual-phase dual SBSE which was consisted of the APTES-OH-TSO-coated and C(18)-PDMS-coated stir bars with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was developed for the simultaneous analysis of six target beverage preservatives in beverages. Under optimal conditions, the limits of detection (LODs) for six target preservatives ranged from 0.6 to 2.7 μgL(-1) with the relative standard deviations (RSDs) of 4.6-9.2% (C(BA,SA)=5 μgL(-1),C(MP)=20 μgL(-1),C(EP,PP,BP)=10 μgL(-1), n=7). The enrichment factors (EFs) were approximately 16-42-fold (theoretical EF was 50-fold). The proposed method was validated by the analysis of six target preservatives in three kinds of beverage samples, and the recoveries for the spiked samples were in the range of 76.6-118.6% for cola, 74.6-17.5% for orange juice, and 83.0-119.1% for herbal tea, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2012.12.061 | DOI Listing |
Small
September 2025
College of Science, Nanjing Forestry University, Nanjing, 210037, China.
Inspired by the rigid exoskeleton and elastic inner tissues of crustaceans, a bilayer gel integrating high-strength rigidity and soft cushioning with high interfacial adhesion (1060 ± 40 J m ) is developed via a stepwise solid-liquid phase crosslinking strategy. Herein, a prefrozen high-concentration polyvinyl alcohol (PVA) solution forms a solid-state structural framework, while a subsequently cast low-concentration PVA solution generates a flexible layer. Partial thawing of the frozen gel during casting triggers molecular chain interpenetration at the interface, synergistically enhanced by controlled molecular penetration, freeze-thaw cycles, and salt-induced crystallization.
View Article and Find Full Text PDFAnal Chem
September 2025
Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological and Chemical Engineering, Jiaxing University, Jiaxing 314001, China.
Despite the promise of electrochemical biosensors in amplified nucleic acid diagnostics, existing high-sensitivity platforms often rely on a multilayer surface assembly and cascade amplification confined to the electrode interface. These stepwise strategies suffer from inefficient enzyme activity, poor mass transport, and inconsistent probe orientation, which compromise the amplification efficiency, reproducibility, and practical applicability. To address these limitations, we report a programmable dual-phase electrochemical biosensing system that decouples amplification from signal transduction.
View Article and Find Full Text PDFJ Colloid Interface Sci
August 2025
Beijing Key Laboratory of Advanced Functional Polymer Composites, Beijing University of Chemical Technology, Beijing 100029, China. Electronic address:
Lithium‑sulfur batteries (LSBs) are promising alternatives to lithium-ion batteries due to their high energy density and low cost. However, issues like the lithium polysulfide (LiPSs) shuttle effect, lithium dendrite growth, and flammable electrolytes hinder commercialization. In this study, we have developed a metal-based catalyst, bismuth oxychloride (BiOCl) nanoflowers coated with conductive polypyrrole (Bi@Ppy), via hydrothermal synthesis.
View Article and Find Full Text PDFAdv Sci (Weinh)
September 2025
Department of Biomedical Engineering, College of Engineering and Applied Sciences, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, 210023, China.
Heat shock protein 70 (HSP70) represents a critical barrier to effective mild-temperature photothermal therapy (MPTT), limiting its clinical utility in aggressive cancers like triple-negative breast cancer (TNBC). While small interfering RNA (siRNA)-mediated HSP70 suppression offers a promising solution, optimal timing for this therapeutic combination remains unexplored. Here, it is demonstrated that precisely timed administration significantly enhances MPTT efficacy through systematic temporal characterization of HSP70 expression dynamics.
View Article and Find Full Text PDFEur Radiol
September 2025
Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Objectives: This study compared three-dimensional myocardial extracellular volume (ECV) quantification among single-phase and dual-phase photon-counting detector computed tomography (PCD-CT) and dual-phase energy-integrating detector computed tomography (EID-CT), using cardiac magnetic resonance (CMR) imaging as the reference.
Materials And Methods: This retrospective study included 80 patients who underwent both CMR and cardiac CT (40 patients underwent PCD-CT and 40 underwent EID-CT). Pearson correlation coefficients and intraclass correlation coefficients (ICCs) were used to evaluate the correlation and reliability of CT-ECV with CMR-ECV.