Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Rapid and sensitive detection of Escherichia coli (E. coli) is crucial for ensuring water safety. Traditional culture-based detection technologies are time-consuming, cumbersome, and difficult to meet immediate needs, while existing instrument-based detection is costly, time-consuming, and struggle to process complex samples. Herein, a microfluidic system for rapid enrichment and sensitive detection of E. coli in water based on bilayer membrane and high flux droplets is proposed. The bilayer membrane structure can enrich bacteria while removing impurities in the sample. High-throughput droplets can encapsulate single bacteria for enzymatic reactions within the droplets, reducing the reaction system to nanoliter, and greatly shortening the reaction time. The results showed that the detection of E. coli solution with different concentrations by this system had little difference compared to the plate counting method, demonstrating a good linear relationship (R = 0.9968) and the detection of total coliform in sewage has an accuracy rate of at least 80 %. In summary, this system combines enrichment technology with microdroplet technology to detect E. coli for the first time. It can achieve 50-fold enrichment of E. coli in water and bacteria isolation in 100 μL solution with tens of thousands of droplets, which greatly improves the sensitivity and efficiency of detection, thus showing great potential for ensuring water safety.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2025.128005DOI Listing

Publication Analysis

Top Keywords

sensitive detection
12
detection coli
12
bilayer membrane
12
microfluidic system
8
system rapid
8
rapid enrichment
8
enrichment sensitive
8
detection
8
based bilayer
8
membrane high
8

Similar Publications

Background: Ecological momentary assessment (EMA) is increasingly being incorporated into intervention studies to acquire a more fine-grained and ecologically valid assessment of change. The added utility of including relatively burdensome EMA measures in a clinical trial hinges on several psychometric assumptions, including that these measure are (1) reliable, (2) related to but not redundant with conventional self-report measures (convergent and discriminant validity), (3) sensitive to intervention-related change, and (4) associated with a clinically relevant criterion of improvement (criterion validity) above conventional self-report measures (incremental validity).

Objective: This study aimed to evaluate the reliability, validity, and sensitivity to change of conventional self-report versus EMA measures of rumination improvement.

View Article and Find Full Text PDF

Programmable Dual-Phase Electrochemical Biosensor Combines Homogeneous CRISPR/Cas12a Activation with Interfacial Poly-G Signaling for miRNA-21 Detection.

Anal Chem

September 2025

Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological and Chemical Engineering, Jiaxing University, Jiaxing 314001, China.

Despite the promise of electrochemical biosensors in amplified nucleic acid diagnostics, existing high-sensitivity platforms often rely on a multilayer surface assembly and cascade amplification confined to the electrode interface. These stepwise strategies suffer from inefficient enzyme activity, poor mass transport, and inconsistent probe orientation, which compromise the amplification efficiency, reproducibility, and practical applicability. To address these limitations, we report a programmable dual-phase electrochemical biosensing system that decouples amplification from signal transduction.

View Article and Find Full Text PDF

Mimicking human brain functionalities with neuromorphic devices represents a pivotal breakthrough in developing bioinspired electronic systems. The human somatosensory system provides critical environmental information and facilitates responses to harmful stimuli, endowing us with good adaptive capabilities. However, current sensing technologies often struggle with insufficient sensitivity, dynamic response, and integration challenges.

View Article and Find Full Text PDF

In charge detection mass spectrometry (CD-MS) ions are trapped in an electrostatic linear ion trap (ELIT) where they oscillate back and forth through a conducting cylinder. The oscillating ions induce a periodic charge separation that is detected by a charge sensitive amplifier (CSA) connected to the cylinder. The resulting time domain signal is analyzed using short-time Fourier transforms to give the mass-to-charge ratio and charge for each ion, which are then multiplied to give the mass.

View Article and Find Full Text PDF

Purpose: To evaluate inter-grader variability in posterior vitreous detachment (PVD) classification in patients with epiretinal membrane (ERM) and macular hole (MH) on spectral-domain optical coherence tomography (SD-OCT) and identify challenges in defining a reliable ground truth for artificial intelligence (AI)-based tools.

Methods: A total of 437 horizontal SD-OCT B-scans were retrospectively selected and independently annotated by six experienced ophthalmologists adopting four categories: 'full PVD', 'partial PVD', 'no PVD', and 'ungradable'. Inter-grader agreement was assessed using pairwise Cohen's kappa scores.

View Article and Find Full Text PDF