Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This study determined the predictive accuracy of optical frequency domain imaging (OFDI) on debulking effects of rotational atherectomy (RA) and compared the predictive accuracy of OFDI catheter-based with Rota wire-based prediction methods. This prospective, single-center, observational study included 55 consecutive patients who underwent OFDI-guided RA. On pre-RA OFDI images, a circle, identical to the Rota burr was drawn at the center of the OFDI catheter (OFDI catheter-based prediction method) or wire (wire-based prediction method). The area overlapping the vessel wall was defined as the predicted ablation area (P-area). The actual ablated area (A-area) was measured by superimposing the OFDI images before and after RA. The overlapping P-area and A-area were defined as overlapped ablation area (O-area), and the predictive accuracy was evaluated by %Correct area (O-area/P-area) and %Error area (A-area  - O-area/A-area). The median %Correct and %Error areas were 47.8% and 41.6%, respectively. Irrelevant ablation (low %Correct-/high % Error areas) and over ablation (high %Correct-/high % Error areas) were related to deep vessel injury and intimal flap outside the P-area. The predictive accuracy was better in the OFDI catheter-based prediction method than the wire-based prediction method in the cross sections where the OFDI catheter and wire came in contact. However, it was better in the latter than the former where the OFDI catheter and wire were not in contact. OFDI-based simulation of the RA effect is feasible though accuracy may be affected by the OFDI catheter and wire position. OFDI-based simulation of RA effect might reduce peri-procedural complications during RA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10247835PMC
http://dx.doi.org/10.1007/s12928-023-00928-9DOI Listing

Publication Analysis

Top Keywords

predictive accuracy
16
ofdi catheter
16
prediction method
16
ofdi catheter-based
12
wire-based prediction
12
catheter wire
12
ofdi
10
rotational atherectomy
8
optical frequency
8
frequency domain
8

Similar Publications

Importance: Increasingly, strategies to systematically detect melanomas invoke targeted approaches, whereby those at highest risk are prioritized for skin screening. Many tools exist to predict future melanoma risk, but most have limited accuracy and are potentially biased.

Objectives: To develop an improved melanoma risk prediction tool for invasive melanoma.

View Article and Find Full Text PDF

Importance: Right anomalous aortic origin of a coronary artery (R-AAOCA) is a rare congenital condition increasingly diagnosed with the growing use of cardiac imaging. Due to dynamic compression of the anomalous vessel, invasive fractional flow reserve (FFR) during a dobutamine-atropine volume challenge (FFR-dobutamine) is considered the reference standard. A reliable alternative method is needed to reduce extensive invasive testing, but it remains uncertain whether noninvasive imaging can accurately assess the hemodynamic relevance of R-AAOCA.

View Article and Find Full Text PDF

Purpose: To build computed tomography (CT)-based radiomics models, with independent external validation, to predict recurrence and disease-specific mortality in patients with colorectal liver metastases (CRLM) who underwent liver resection.

Methods: 113 patients were included in this retrospective study: the internal training cohort comprised 66 patients, while the external validation cohort comprised 47. All patients underwent a CT study before surgery.

View Article and Find Full Text PDF

Background: The optimal number of examined lymph nodes (ELN) for accurate staging and prognosis for esophageal cancer patients receiving neoadjuvant therapy remains controversial. This study aimed to evaluate the impact of ELN count on pathologic staging and survival outcomes and to develop a predictive model for lymph node positivity in this patient population.

Methods: Data were extracted from the Surveillance, Epidemiology, and End Results (SEER) database and a multicenter cohort.

View Article and Find Full Text PDF

Rational Hapten Design for the Immunochromatographic Assay of Yohimbine, an Emerging Adulterant in Food.

J Agric Food Chem

September 2025

Guangdong Provincial Key Laboratory of Food Quality and Safety/Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, South China Agricultural University, Guangzhou 510642, China.

Adulterated yohimbine (YHB) in food poses a risk to public health, making it imperative to develop fast and sensitive detection methods. In this study, computational-chemistry-based prediction was employed to design YHB haptens for generating the high-affinity monoclonal antibody Yohi-4A7, which exhibited an optimal half-inhibitory concentration (IC) of 1.69 ng/mL against YHB.

View Article and Find Full Text PDF