98%
921
2 minutes
20
Ultrasensitively selective detection of trace polycyclic aromatic hydrocarbons (PAHs) like phenanthrene (PHE) is critical but remains challenging. Herein, atomically dispersed Zn sites on g-C N nanosheets (sZn-CN) are constructed by thermal polymerization of a Zn-cyanuric acid-melamine supramolecular precursor for the fluorescence detection of PHE. A high amount (1.6 wt%) of sZn is grafted in the cave of CN with one N vacancy in the form of unique Zn(II)N coordination. The optimized sZn-CN achieves a wide detection range (1 ng L to 5 mg L ), ultralow detection limit (0.35 ng L , with 5-order magnitude improvement over CN), and ultrahigh selectivity toward PHE even among typical PAHs based on the built PHE-CN dual ratiometric fluorescence method. By means of in situ Fourier transform infrared spectroscopy, time-resolved absorption and fluorescence spectroscopy, and theoretical calculations, the resulting superior detection performance is attributed to the favorable selective adsorption of PHE on as-constructed atomic Zn(II)N sites via the ionic cation-π interactions (Zn C type), and the fluorescence quenching is dominated by the inner filter effect (IFE) from the multilayer adsorption of PHE at low concentrations, while it is done by the protruded photogenerated electron-transfer process, as well as IFE from the monolayer adsorption of PHE at ultralow concentration.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/adma.202211575 | DOI Listing |
J Biosci Bioeng
September 2025
Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama 700-8530, Japan.
Blood purification using immunoadsorbent columns is a therapeutic strategy for removing pathogenic autoantibodies in autoimmune diseases. Currently available columns have limitations: Trp/Phe columns offer cost-effectiveness and sterilizability, but lack antigen specificity and have limited capacity to remove diverse pathogenic autoantibodies; whereas Protein A/peptide/anti-human IgG columns target all antibodies, regardless of pathogenicity, limiting specificity, and often require sterile production due to low stability under sterilization conditions, except for peptide ligands. Full-length autoantigen-immobilized immunoadsorbent columns have great potential to specifically adsorb targeted autoantibodies, because autoantibodies recognize diverse epitopes that vary among individuals.
View Article and Find Full Text PDFInt J Biol Macromol
September 2025
Shanghai Key Laboratory of Pediatric Gastroenterology and Nutrition, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200092, China; Department of Clinical Nutrition, College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 20013
Low-Phe protein-based substances are an important clinical requirement for the development of medical foods. Herein, a combination method of two-step enzymatic hydrolysis with activated carbon adsorption removal was applied to prepare low-Phe whey protein polypeptides (LWPs). The two-step enzymatic hydrolysis was affected by enzyme/casein mass ratios and times.
View Article and Find Full Text PDFEnviron Res
June 2025
College of Advanced Agriculture and Ecological Environment, Heilongjiang University, Harbin, 150006, PR China. Electronic address:
Phenanthrene (PHE) serves as a representative polycyclic aromatic hydrocarbon (PAH) that poses a significant risk to ecosystems and human health owing to its persistence and biotoxicity. A novel bio-mineral system was developed by integrating natural birnessite with the PHE-degrading strain Novosphingobium sp. HDJX-2 to address the need for effective remediation, which achieved the complete degradation of PHE within 72 h.
View Article and Find Full Text PDFEnviron Geochem Health
June 2025
School of Water and Environment, Chang'an University, Middle South Second Ring Road, Xi'an, 710061, Shaanxi Province, China.
Microplastics (MPs) in ecosystems have garnered attention, yet their effects on the environmental behavior of organic pollutants in river sediments remain poorly understood. This study investigated how polyethylene (PE) and polyvinyl chloride (PVC) MPs influence the adsorption and migration of Phenanthrene (Phe) in sediments via batch and column experiments. Results revealed that sediment adsorption capacity for Phe followed: sediment containing 2% PE (120.
View Article and Find Full Text PDFNanoscale
June 2025
School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China.
Pt/TiO photocatalysts were synthesized using incipient wetness impregnation followed by oxidative and/or reductive thermal treatments. The loading dimensions of Pt elements on the TiO surface (Pt, Pt, and Pt) were controlled by varying the impregnated solution. Experimental results demonstrate that Pt with an intermediate size exhibits the highest photolysis rate under 300 W xenon lamp irradiation, achieving a hydrogen yield of 11.
View Article and Find Full Text PDF