Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Transarterial chemoembolization is the standard treatment option for intermediate-stage hepatocellular carcinoma (HCC). However, during the interventional procedure, occupational radiation protection is compromised. The use of real-time radiation dosimetry could provide instantaneous radiation doses. This study aimed to evaluate the occupational dose of the medical staff using a real-time radiation dosimeter during transarterial chemoembolization (TACE) for HCC, and to investigate factors affecting the radiation exposure dose.This retrospective observational study included 70 patients (mean age: 66 years; age range: 38-88 years; male: female = 59: 11) who underwent TACE using real-time radiation dosimetry systems between August 2018 and February 2019. Radiation exposure doses of operators, assistants, and technicians were evaluated. Patients' clinical, imaging, and procedural information was analyzed.The mean dose-area product (DAP) and fluoroscopy time during TACE were 66.72 ± 55.14 Gycm2 and 12.03 ± 5.95 minutes, respectively. The mean radiation exposure doses were 24.8 ± 19.5, 2.0 ± 2.2, and 1.65 ± 2.0 μSv for operators, assistants, and technicians, respectively. The radiation exposure of the operators was significantly higher than that of the assistants or technicians (P < .001). The perpendicular position of the adjustable upper-body lead protector (AULP) on the table was one factor reducing in the radiation exposure of the assistants (P < .001) and technicians (P = .040). The DAP was a risk factor for the radiation exposure of the operators (P = .003) and technicians (P < .001).Occupational doses during TACE are affected by DAP and AULP positioning. Placing the AULP in the perpendicular position during fluoroscopy could be a simple and effective way to reduce the radiation exposure of the staff. As the occupational dose influencing factors vary by region or institution, further study is needed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8797565PMC
http://dx.doi.org/10.1097/MD.0000000000028744DOI Listing

Publication Analysis

Top Keywords

radiation exposure
20
transarterial chemoembolization
12
real-time radiation
12
assistants technicians
12
radiation
10
occupational dose
8
hepatocellular carcinoma
8
radiation dosimetry
8
exposure doses
8
operators assistants
8

Similar Publications

Resistance to chemotherapy remains a significant challenge for the treatment of pancreatic cancer. In addition to conventional therapeutic strategies, photodynamic therapy (PDT) has emerged as a compelling alternative for pancreatic cancer as it synergizes with various chemotherapeutics such as irinotecan, and oxaliplatin. However, the exact mechanisms by which PDT overcomes oxaliplatin resistance remains elusive.

View Article and Find Full Text PDF

Radiofrequency electromagnetic radiation (RF-EMR) is ubiquitous in daily life, and the complexity of the electromagnetic environment continues to increase. Nevertheless, research on the biological effects of compound radiofrequency radiation-particularly its influence on lipid metabolism under realistic exposure scenarios-remains limited, and the underlying mechanisms are not yet fully elucidated. To investigate the impact of compound radiofrequency radiation on lipid metabolism, multi-frequency radiation exposure model both normal and obese mice were established.

View Article and Find Full Text PDF

Optimization of carotid CT angiography image quality with deep learning image reconstruction with high setting (DLIR-H) algorithm under ultra-low radiation and contrast agent conditions.

Radiography (Lond)

September 2025

Department of Radiology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, 221002, China; School of Medical Imaging, Xuzhou Medical University, Xuzhou, Jiangsu, 221002, China; Jiangsu Provincial Engineering Research Center for Medical Imaging and Digital Medicine, Xuzhou, Jiangs

Introduction: Carotid artery disease is a major cause of stroke and is frequently evaluated using Carotid CT Angiography (CTA). However, the associated radiation exposure and contrast agent use raise concerns, particularly for high-risk patients. Recent advances in Deep Learning Image Reconstruction (DLIR) offer new potential to enhance image quality under low-dose conditions.

View Article and Find Full Text PDF

Aim: Radiation-induced hepatotoxicity is a major challenge during radiotherapy. This study aims to evaluate the potential ameliorative outcome and underlying mechanisms of liraglutide (LIRA) in mitigating acute liver injury caused by radiation exposure in vivo.

Methods: Animals were administered LIRA subcutaneously (50 µg/kg/twice daily) for two weeks, and then exposed to whole body γ-radiation (6 Gy) 1 h after the last LIRA dose.

View Article and Find Full Text PDF

At Semipalatinsk nuclear test site (SNTS), nuclear weapons tests lasted from 1949 to 1989, with a total of 468 nuclear weapons explosions (including 117 air and ground tests) being conducted. The aim of our study is to evaluate trends in the field of conducted research on the assessment of the health status of the population of Kazakhstan exposed to radiation as a result of nuclear weapons testing at the STNS, as well as the contribution of various countries, institutions, journals and authors to these studies. Research methods included: formulating research questions; selecting databases to search for the information of interest; collecting information on publications; selecting a program to conduct bibliometric analysis; creating maps according to research questions; analyzing bibliometric data.

View Article and Find Full Text PDF