Background: This study presents different zirconia additive manufacturing (AM) materials and technologies while assessing the fit, hardness, and shear bond strength of crowns produced by AM and subtractive manufacturing (SM) methods, as well as their surface characteristics.
Methods: Zirconia crowns were fabricated using a 5-axis SM and five AM approaches, including four digital light processing principles and one stereolithography (SLA) technique. Each method utilized varying slurry delivery and light-curing mechanisms.
Background: Given the critical role of health professionals in societal health, the development of robust and effective selection methods is of fundamental concern for educational institutions within the field of health sciences education. Conventionally, admission competencies have been determined by institutional authorities. Developing institution-specific competency criteria enables an admission process that is mission- and value-aware, evidence-based, and strategically adaptable.
View Article and Find Full Text PDFPurpose: This study investigates the role and effectiveness of the epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) in oral cancer, focusing on the clinical relevance of EGFR and myeloid cell leukemia-1 (Mcl-1) in head and neck cancers (HNCs). It aims to explore the molecular mechanism of afatinib, a TKI, in treating human oral cancer.
Methods: We conducted an in silico analysis using databases like The Cancer Genome Atlas, Gene Expression Omnibus, and Clinical Proteomic Tumor Analysis Consortium, along with immunohistochemistry staining, to study EGFR and Mcl-1 expression in HNCs.
Objective: This study aims to evaluate food impaction on three-dimensional (3D) printed models with periodontal ligament simulation.
Materials And Methods: Based on a commercial typodont pair, 3D maxillary and mandibular models were created with no teeth and with tooth sockets that were 1 mm wider than the original ones from 24 to 27 or 34 to 37 for periodontal ligament simulation with vinyl polysiloxane impression material. In total, 35 pairs of 7 combinations, including maxillary/mandibular typodonts in occlusion with maxillary/mandibular 3D models with/without a distal gap of canines on 3D models (tooth 23 or 33) were mounted on hinge articulators and divided into seven groups (n = 5).
This study aimed to evaluate the effects of dentin bonding agents and silanization on the bond strength between 3D printed resin and composite resin and compare it with a conventional composite resin. 3D printed resin cylinders (PCB) and composite resin substrates (Z250) were prepared and divided into eight subgroups based on the bonding agents used (n=12). The shear bond strength was measured using a universal testing machine, and the failure modes were evaluated.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
June 2024
Objectives: The dentist-patient relationship (DPR) is considered to be a key element in dental clinical settings. This scoping review aimed to examine the extent of previous research on DPR, focussing on its determinants for the reification of the construct.
Methods: This research was directed by the guidance for systematic scoping reviews from the Joanna Briggs Institute.
Abstract Background/purpose: The presence of restorative material between resin cement and the light-curing unit can reduce light transmission. This study aimed to evaluate the effect of the light-blocking effect of zirconia crown on shear bond strength (SBS) between three dual-cured resin cements and the zirconia surface.
Materials And Methods: Sixty zirconia specimens were prepared and divided into three groups according to the type of resin cement [RXU (RelyX Ultimate); SC2 (SmartCem2); MEC (Maxcem Elite Chroma)].
This study aimed to evaluate the efficacy of a novel jet dispenser (JD) for filling simulated straight and curved canals with calcium hydroxide (Ca(OH)) paste by comparing the level of intracanal medicament with traditional direct syringe delivery. The Ca(OH) paste was delivered into the canals using either a direct syringe with binding tip and unbinding tip or a JD. The analysis of the ratio of the canal filled area (RCFA) in the coronal, middle, and apical thirds was conducted using the Kruskal-Wallis and Mann-Whitney U tests (α = 0.
View Article and Find Full Text PDFActa Odontol Scand
January 2024
Objective: Coffee is one of the most popular beverages in the world, with millions of people consuming it every day. The effect of coffee on teeth discoloration has long been a concern for both coffee drinkers and dental professionals. To address this concern, this study aimed to investigate the role of chlorogenic acids (CGAs) and the type of coffee in coffee-induced teeth discoloration.
View Article and Find Full Text PDFJ Prosthet Dent
December 2024
This study evaluated the effect of vibration on adaptation of bulk-fill composite resin. A scanning laser doppler vibrometer measured the frequency and amplitude of a vibratory device (COMO; B&L Biotech) used for resin placement and visualized its effect on the resin according to depth. A bulk-fill composite resin (Filtek Bulk Fill; 3M ESPE) was placed in simulated cavities (4 mm diameter, 4 mm depth) by different layering methods (incremental filling with two 2-mm-thick layers vs.
View Article and Find Full Text PDFAim: The objective of this study was to evaluate the bond strength of universal adhesive systems in self-etch and etch-and-rinse modes at the repair interface between aged and new composite resins.
Materials And Methods: Composite resin (Filtek Z250) was thermocycled to represent aged composite resin to be repaired. New composite resin was placed over the aged substrate after surface conditioning: NC (negative control, no surface treatment), A (adhesive only), SBM (Scotchbond Multi-Purpose in etch-and-rinse mode), CSE (Clearfil SE Bond in self-etch mode), SBU (Single Bond Universal), ABU (All Bond Universal), and TBU (Tetric N-Bond Universal).
Materials (Basel)
March 2021
With the advent of 3D printing technologies in dentistry, the optimization of printing conditions has been of great interest, so this study analyzed the accuracy of 3D-printed temporary restorations of different sizes produced by digital light processing (DLP) and liquid crystal display (LCD) printers. Temporary restorations of 2-unit, 3-unit, 5-unit, 6-unit, and full-arch cases were designed and printed from a DLP printer using NextDent C&B or an LCD printer using Mazic D Temp ( = 10 each). The restorations were scanned, and each restoration standard tessellation language (STL) file was superimposed on the reference STL file, by the alignment functions, to evaluate the trueness through whole/point deviation.
View Article and Find Full Text PDFFew investigations have evaluated the 3-dimensional (3D) accuracy of digital implant scans. The aim of this study was to evaluate the performance of 10 intraoral scanners (IOSs) (CEREC Omnicam, CEREC Primescan, CS 3600, DWIO, i500, iTero Element, PlanScan, Trios 2, Trios 3, and True Definition) in obtaining the accurate positions of 6 cylinders simulating implant scan bodies. Digital scans of each IOS were compared with the reference dataset obtained by means of a coordinate measuring machine.
View Article and Find Full Text PDFStatement Of Problem: Studies evaluating the trueness of intraoral scanners (IOSs) at anatomic locations within an intracoronal preparation are lacking.
Purpose: The purpose of this in vitro study was to evaluate the trueness of digital scans obtained by IOSs at the margin and intaglio surfaces of intracoronal preparations.
Material And Methods: Six IOSs (CEREC Omnicam, E4D, FastScan, iTero, TRIOS, Zfx IntraScan) were used to obtain digital scans of various intracoronal preparations.
Purpose This study aimed to evaluate the influence of tooth location and inlay cavity type on the accuracy of intraoral digital impressions.Methods Class II inlay preparation was performed on anatomical models of the maxillary first molar (16) and mandibular first molar (46). Mesio-occlusal and disto-occlusal cavities were prepared, such that the axial wall of the proximal box measured 1 mm or 2 mm in height.
View Article and Find Full Text PDFEur J Dent Educ
February 2021
Introduction: Accurate clinical decision-making of dentists should be based on their knowledge and experience. In the past 10 years, interest in competency-based dentistry education has rapidly increased, but there has been little attention paid to methods of improving dental education competency. The purpose of this study was to develop a clinical presentation education model that provides opportunities for students to practice problem-solving from the moment they greet the patient so that students can obtain the practical experience of competency-based education and the effectiveness of this model can be confirmed through pilot test.
View Article and Find Full Text PDFContext: Dental schools seek to educate students to become inclined toward self-directed, lifelong learning, an important mindset for healthcare professionals that may be linked to deep versus surface learning approaches. Students using a deep learning approach are more intrinsically motivated and actively engage in higher-order thinking, while those using a surface learning approach are more extrinsically motivated and aim for passive learning.
Objectives: Because student learning approaches can be influenced by a wide variety of learning experiences, we sought to understand how student approaches to learning differ by year in dental school and are related to academic achievement.
The aim of this study was to evaluate the trueness of 5 intraoral scanners (IOSs) for digital impression of simulated implant scan bodies in a partially edentulous model. A 3D printed partially edentulous mandible model made of Co-Cr with a total of 6 bilaterally positioned cylinders in the canine, second premolar, and second molar area served as the study model. Digital scans of the model were made with a reference scanner (steroSCAN neo) and 5 IOSs (CEREC Omnicam, CS3600, i500, iTero Element, and TRIOS 3) (n = 10).
View Article and Find Full Text PDFWe aimed to evaluate the risk of coronary heart disease (CHD) according to dental caries status in middle-aged patients using a population-based cohort database containing medical/dental claims, health examination, and death records in the Republic of Korea. A total of 234,597 patients were identified in the database who were without history of cardiovascular disease, including 104,638 patients without dental caries, 41,696 with incipient/moderate stage dental caries, and 88,262 advanced/severe dental caries. We used Cox proportional hazards model adjusted for sociodemographic, lifestyle, and medical characteristics to compute hazard ratio (HR) and 95% confidence intervals (95% CI) for CHD according to severity of dental caries.
View Article and Find Full Text PDFJ Prosthet Dent
January 2020
Statement Of Problem: Although studies have reported the trueness and precision of intraoral scanners (IOSs), studies addressing the accuracy of IOSs in reproducing inlay preparations are lacking.
Purpose: The purpose of this in vitro study was to compare the accuracy of representative IOSs in obtaining digital scans of inlay preparations and to evaluate whether the IOSs had sufficient depth of field to obtain accurate images of narrow and deep cavity preparations.
Material And Methods: Digital scans of a bimaxillary typodont with cavity preparations for inlay restorations on the maxillary first premolar, first and second molar, mandibular second premolar, and first molar were obtained using 6 IOSs (CEREC Omnicam, E4D, FastScan, iTero, TRIOS, and Zfx IntraScan).
Statement Of Problem: Different intraoral scanners (IOSs) are available for digital dentistry. However, information on the accuracy of various IOSs for complete-arch digital scans is limited.
Purpose: The purpose of this in vitro study was to evaluate the trueness and precision of complete-arch digital scans produced by 9 IOSs, using the superimposition method, and to compare them based on characteristics including the data capture principle and mode and the need for powder coating.
Objectives: The purpose of this study was to investigate temperature rise in the composite and dentin of a class I cavity in extracted human molars under different restoration conditions, including the use of different composite types, layering methods, and curing lights.
Methods: Open occlusal cavities were prepared on 28 extracted human molars. A conventional (Filtek Z250) and a bulk-fill (Filtek Bulk Fill Posterior; BFP) composite were used to restore the preparations.