Publications by authors named "Daniel Overhoff"

Disorders of olfaction are a frequent reason for an assessment in otorhinolaryngology. Particularly when the results of subjective and/or objective olfactometry are inconclusive, additional objective findings are required to verify disorders of the sense of smell. Based on practical experience and considering the current literature, this article is intended as an aid in the preparation of supplementary radiological reports.

View Article and Find Full Text PDF

Objectives: This study aimed to investigate the consistency of lesion identification by Prostate Imaging Reporting and Data System (PI-RADS) and the related clinical and histological characteristics in a high-volume tertiary care center.

Materials And Methods: The analysis used real-world data from 111 patients between 2018 and 2022. Each patient underwent two multiparametric magnetic resonance imaging (MRI) scans of the prostate at different institutions with a median interval of 42 days between the scans, followed by an MRI-fused biopsy conducted 7 days after the second MRI.

View Article and Find Full Text PDF

Background And Purpose: The complex anatomy of the petrous part of the temporal bone (or petrous temporal bone) is difficult to understand and constitutes a challenge in the daily diagnostic routine even for experienced neuroradiologists. High-resolution computed tomography (HRCT) is an integral part of equipment-based diagnostics of the rare entity of posterior semicircular canal dehiscence (PSCD). PSCD is characterised by an absence of the bony cover of the posterior semicircular canal in the petrous temporal bone.

View Article and Find Full Text PDF

The increasing use of computed tomography (CT) has led to a rise in cumulative radiation dose due to medical imaging, raising concerns about potential long-term adverse effects. Large-scale epidemiological studies indicate a higher tumor incidence associated with CT examinations, but the underlying biological mechanisms remain largely unexplained. To gain further insights into the cellular response triggered by routine CT diagnostics, we investigated CT-induced changes of gene expression in peripheral blood cells using whole transcriptome sequencing.

View Article and Find Full Text PDF

Objectives: Urolithiasis, a common and painful urological condition, is influenced by factors such as lifestyle, genetics, and medication. Differentiating between different types of kidney stones is crucial for personalized therapy. The purpose of this study is to investigate the use of photon-counting computed tomography (PCCT) in combination with radiomics and machine learning to develop a method for automated and detailed characterization of kidney stones.

View Article and Find Full Text PDF

Background: For treatment of urolithiasis, the stone composition is of particular interest, as uric acid (UA) stones can be treated by chemolitholysis. In this ex vivo study, we employed an advanced composition analysis approach for urolithiasis utilizing spectral data obtained from a photon-counting detector CT (PCDCT) to differentiate UA and non-UA stones. Our primary objective was to assess the accuracy of this analysis method.

View Article and Find Full Text PDF
Article Synopsis
  • This study aimed to assess the effectiveness of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) in identifying severe lung injuries and atelectasis in patients with multiple traumas.
  • A total of 20 patients were examined using contrast-enhanced PCD-CT, with images created at different energy levels (40 to 120 keV) to analyze the contrast-to-noise ratio between injured and collapsed lung areas.
  • Results showed that lower energy levels (specifically around 40-50 keV) provided the best contrast and clarity for differentiating between severe lung injury and atelectasis, while higher energy levels like 60-70 keV offered better noise perception
View Article and Find Full Text PDF

Purpose: Preliminary dual-energy CT studies have shown that low-energy virtual monoenergetic (VMI) + reconstructions can provide superior image quality compared to standard 120 kV CTA series. The purpose of this study is to evaluate the impact of low-energy VMI reconstructions on quantitative and qualitative image quality, vascular contrast, and diagnostic assessability of the carotid artery in patients undergoing photon-counting CTA examinations.

Materials And Methods: A total of 122 patients (67 male) who had undergone dual-source photon-counting CTA scans of the carotid artery were retrospectively analyzed in this study.

View Article and Find Full Text PDF

Aim: To evaluate the effects of lipid-lowering medications of different intensities on total, calcified, and non-calcified plaque volumes in patients undergoing serial cardiac computed tomography angiography (CCTA).

Methods: Individuals with chronic coronary syndromes from 11 centers were included in a retrospective registry. Total, calcified, and non-calcified plaque volumes were quantified and the relative difference in plaque volumes between baseline and follow-up CCTA was calculated.

View Article and Find Full Text PDF

Purpose: This ex vivo study aimed to compare a newly developed dual-source photon-counting CT (PCCT) with a 3rd generation dual-source dual-energy CT (DECT) for the detection and measurement (stone lengths and volumetrics) of urinary stones.

Methods: 143 urinary stones with a known geometry were physically measured and defined as reference values. Next, urinary stones were placed in an anthropomorphic abdomen-model and were scanned with DECT and PCCT.

View Article and Find Full Text PDF

Purpose: Aim of the recent study is to point out a method to optimize quality of CT scans in oncological patients with port systems. This study investigates the potential of photon counting computed tomography (PCCT) for reduction of beam hardening artifacts caused by port-implants in chest imaging by means of spectral reconstructions.

Method: In this retrospective single-center study, 8 ROIs for 19 spectral reconstructions (polyenergetic imaging, monoenergetic reconstructions from 40 to 190 keV as well as iodine maps and virtual non contrast (VNC)) of 49 patients with pectoral port systems undergoing PCCT of the chest for staging of oncologic disease were measured.

View Article and Find Full Text PDF

Background: Photon-counting detector (PCD) computed tomography (CT) allows for the reconstruction of virtual monoenergetic images (VMI) at different thresholds.

Objective: The aim of our study was to evaluate the optimal arterial contrast in portal venous (pv) scans regarding objective parameters and subjective image quality for different virtual keV levels.

Methods: We identified 40 patients that underwent a CT scan with an arterial and pv phase on a PCD-CT (NAEOTOM alpha, Siemens Healthineers, Forchheim, Germany).

View Article and Find Full Text PDF

Objectives: The aim of this study was to analyze the extent of dental metal artifacts in virtual monoenergetic (VME) images, as they often compromise image quality by obscuring soft tissue affecting vascular attenuation reducing sensitivity in the detection of dissections.

Methods: Neck photon-counting CT datasets of 50 patients undergoing contrast-enhanced trauma CT were analyzed. Hyperattenuation and hypoattenuation artifacts, muscle with and without artifacts and vessels with and without artifacts were measured at energy levels from 40 keV to 190 keV.

View Article and Find Full Text PDF

Purpose: This study investigated the differences in subjective and objective image parameters as well as dose exposure of photon-counting CT (PCCT) compared to cone-beam CT (CBCT) in paranasal sinus imaging for the assessment of rhinosinusitis and sinonasal anatomy.

Methods: This single-centre retrospective study included 100 patients, who underwent either clinically indicated PCCT or CBCT of the paranasal sinus. Two blinded experienced ENT radiologists graded image quality and delineation of specific anatomical structures on a 5-point Likert scale.

View Article and Find Full Text PDF

Introduction: Pericoronary adipose tissue (PCAT) stands in complex bidirectional interaction with the surrounding arteries and is known to be connected to many cardiovascular diseases involving vascular inflammation. PCAT texture may be influenced by other cardiovascular risk factors such as hypercholesterolemia. The recently established photon-counting CT could improve texture analysis and help detect those changes by offering higher spatial resolution and signal-to-noise ratio.

View Article and Find Full Text PDF

Background: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management.

Method: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience.

Results: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level.

View Article and Find Full Text PDF

Pectus excavatum (PE) is a congenital malformation with a funnel-shaped depression of the sternum that can lead to cardiac symptoms. However, there are patients with thoracic constriction (defined as elevated Haller-Index > 3.25 determined by cardiac magnetic resonance imaging (CMR)) without visible evidence of PE, leading to similar complaints.

View Article and Find Full Text PDF

This article describes the technical principles and clinical applications of dual-energy computed tomography (DECT) in the context of cardiothoracic imaging with a focus on current developments and techniques. Since the introduction of DECT, different vendors developed distinct hard and software approaches for generating multi-energy datasets and multiple DECT applications that were developed and clinically investigated for different fields of interest. Benefits for various clinical settings, such as oncology, trauma and emergency radiology, as well as musculoskeletal and cardiovascular imaging, were recently reported in the literature.

View Article and Find Full Text PDF

Objectives: To investigate the effect of a device-assisted suction against resistance Mueller maneuver (MM) on transient interruption of contrast (TIC) in the aorta and pulmonary trunk (PT) on computed tomography pulmonary angiogram (CTPA).

Methods: In this prospective single-center study, 150 patients with suspected pulmonary artery embolism were assigned randomly with two different breathing maneuvers (Mueller maneuver (MM) or standard end-inspiratory breath-hold command (SBC)) during routine CTPA. The MM was performed using a patented prototype (Contrast Booster™) which allows both the patient by means of visual feedback and the medical staff in the CT scanning room to monitor whether the patient is sucking sufficiently or not.

View Article and Find Full Text PDF

Background: Type 2 diabetes mellitus (DM) is the most common metabolic disorder in the world and an important risk factor for peripheral arterial disease (PAD). CT angiography represents the method of choice for the diagnosis, pre-operative planning, and follow-up of vascular disease. Low-energy dual-energy CT (DECT) virtual mono-energetic imaging (VMI) has been shown to improve image contrast, iodine signal, and may also lead to a reduction in contrast medium dose.

View Article and Find Full Text PDF

Purpose: The novel photon-counting detector (PCD) technique acquires spectral data for virtual monoenergetic imaging (VMI) in every examination. The aim of this study was the evaluation of the impact of VMI of abdominal arterial vessels on quantitative and qualitative subjective image parameters.

Methods: A total of 20 patients that underwent an arterial phase computed tomography (CT) scan of the abdomen with a novel PCD CT (Siemens NAEOTOM alpha) were analyzed regarding attenuation at different energy levels in virtual monoenergetic imaging.

View Article and Find Full Text PDF
Article Synopsis
  • * Results showed that PC-CT provided sharper images and lower noise levels, with significant improvements in image quality and diagnostic confidence, especially in patients with metallic implants.
  • * Additionally, PC-CT resulted in a substantially lower radiation dose, making it a safer alternative compared to EID-CT in spinal imaging assessments.
View Article and Find Full Text PDF

Background: Photon-counting computed tomography (PCCT) is a promising new technology with the potential to fundamentally change today's workflows in the daily routine and to provide new quantitative imaging information to improve clinical decision-making and patient management.

Method: The content of this review is based on an unrestricted literature search on PubMed and Google Scholar using the search terms "Photon-Counting CT", "Photon-Counting detector", "spectral CT", "Computed Tomography" as well as on the authors' experience.

Results: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCCT allows counting of every single photon at the detector level.

View Article and Find Full Text PDF

Objectives: Photon-counting computed tomography has lately found its way into clinical routine. The new technique could offer substantial improvements regarding general image quality, image noise, and radiation dose reduction. This study evaluated the first abdominal examinations in clinical routine and compared the results to conventional computed tomography.

View Article and Find Full Text PDF

We hypothesized that myocardial septal scarring, assessed by cardiac magnetic resonance (CMR) using late gadolinium enhancement (LGE), at the site of cardiac contractility modulation (CCM) lead placement may predict treatment response. Eligible heart failure (HF) patients underwent LGE CMR imaging before CCM device implantation. The response to CCM therapy at follow-up was determined by a change in NYHA class and echocardiographic left ventricular ejection fraction (LVEF) assessment.

View Article and Find Full Text PDF