Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Aims: Sealing devices can produce mechanical and thermal damage to collateral tissue, with few studies analyzing these effects. However, the least harmful device for the surrounding tissue will achieve optimal functional results.

Methods: We compared the tissue damage made by different laparoscopic electro-cauterization instruments while using them as hemostatic means on the stomach and epiploon of Wistar rats, respectively on the diaphragm and urinary bladder of a porcine model. Five devices were used based on either radio frequency diathermy or ultrasound energy, with one coagulation cycle for the automatic hemostasis. Infrared thermography tracked thermal injury on the collateral tissue made by each device on the porcine model.

Results: We analyzed the collateral tissue with irreversible thermal damage caused by each sealing device with infrared thermography with ANOVA statistical test. Based on histopathological examination, we calculated the mean value of the area with edema and coagulation necrosis caused by these maneuvers of hemostasis as a pattern of tissue damage around the sealing mark of every hemostatic device.

Conclusions: Compared with bipolar sealing devices, ultrasound-based devices offered better collateral tissue preservation, with the smallest damaging temperature spread, on animal models. Further research on ultrasound vs. bipolar sealing devices used as hemostatic tools could more accurately assess their impact on functional outcomes in real life surgery setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12070907PMC
http://dx.doi.org/10.15386/mpr-2768DOI Listing

Publication Analysis

Top Keywords

sealing devices
16
collateral tissue
16
animal models
8
tissue
8
surrounding tissue
8
thermal damage
8
tissue damage
8
infrared thermography
8
bipolar sealing
8
devices
6

Similar Publications

Marine organism-inspired tough and adhesive patch based on thermosensitive quaternized chitin for tissue sealing/repair and hemostasis.

Carbohydr Polym

November 2025

Key Laboratory of Biomedical Polymers, Ministry of Education, Department of Chemistry, Wuhan University, Wuhan 430072, PR China. Electronic address:

Tissue adhesives have emerged as a promising alternative to conventional sutures and staplers in the management of hemostasis, tissue defect sealing, and wound repair. However, the efficacy of current bio-adhesives in clinical practice is compromised by the limitations, including poor wet adhesion, inadequate mechanical strength, vulnerability to gastrointestinal fluids, and insufficient hemostatic performance. Herein, a marine organism-inspired tough and adhesive patch (MOTAP) was developed to address these challenges.

View Article and Find Full Text PDF

Radioisotope Thermoelectric Generators (RTGs) are devices that convert heat from radioactive decay into electrical energy and are used in remote locations due to their low maintenance requirements. Various types of RTGs were produced with sources containing large amounts of Strontium-90, which require multiple layers of shielding materials. However, the lack of control and the ease of access to the source increase the biological risk in the event of a breach of the device.

View Article and Find Full Text PDF

BackgroundMany oral medications are manufactured as solid dosage forms, posing challenges for patients with dysphagia-including older adults and children-and creating occupational hazards for healthcare workers who must crush or manipulate hazardous drugs. Existing methods for preparing such medications often involve open systems, exposing staff to cytotoxic agents and risking cross-contamination.ObjectiveTo develop and evaluate a novel, single-use closed-system drug-transfer device (CSTD) designed to crush and dissolve or suspend solid oral medications within a sealed environment, enhancing safety for healthcare workers and improving medication access for patients with swallowing difficulties.

View Article and Find Full Text PDF

Background: Advanced materials and techniques are used to successfully manage the apexification of immature teeth with open apices. The use of mineral trioxide aggregate (MTA), bioceramic sealers, and sodium hypochlorite (NaOCl), combined with internal heating and ultrasonic activation, ensures that canals are cleaned, disinfected, and sealed properly. Magnification devices, such as dental operating microscopes (DOM), provide precise visualization for accurate material placement, while the micro apical placement system ensures void-free MTA delivery.

View Article and Find Full Text PDF

Uncovering internal water-flux and surface-potential dominance in hydrogel-based moisture-enabled power generation: mechanistic insights and performance enhancement.

Mater Horiz

September 2025

Key Laboratory of Enhanced Heat Transfer and Energy Conservation of Education Ministry, School of Chemistry and Chemical Engineering, South China University of Technology, China.

Ambient humidity is an abundant yet underexploited energy reservoir, and its sustained conversion mechanisms remain elusive. This study employs single-layer, bilayer and ion-selective designs, in combination with Kelvin-probe force microscopy and molecular dynamics simulations, to delineate the fundamental physics of hydrogel-based moisture-enabled generators (MEGs). We demonstrate that continuous, directional water flux-rather than ion migration-governs electricity generation: the transport of 1 g of HO through the hydrogel network yields ≈9.

View Article and Find Full Text PDF