98%
921
2 minutes
20
Purpose: This study investigates the impact of orthopedic plates on peripheral nerve stimulation (PNS) during MRI, focusing on how the presence of implants affects PNS thresholds.
Methods: A combination of anatomical electromagnetic and neurophysiological modeling was utilized. Electromagnetic fields in human body models were simulated, both with and without orthopedic plates. Simulations were performed under x-, y-, and z-axis gradient coils, with plates implanted at two clinically relevant locations. Nerve responses were modeled using an established neurophysiological model.
Results: The presence of orthopedic implants significantly influenced nerve stimulation, leading to reductions in stimulation thresholds of up to 80%. Some of the reduced thresholds were close to the PNS limits outlined in International Electrotechnical Commission (IEC) 60601-2-33, suggesting a considerably reduced safety margin compared to cases without implants.
Conclusion: Orthopedic implants can substantially lower the activation thresholds of nearby nerves, with some thresholds approaching the PNS limits defined in IEC 60601-2-33 for MRI gradient field. This finding indicates a reduced safety margin for patients with implants, highlighting the need for more comprehensive safety assessments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mrm.30470 | DOI Listing |
Eur J Orthop Surg Traumatol
September 2025
Department of Orthopaedics, Jupiter Hospital, Thāne, India.
We aim to describe an approach for reducing the posteriorly dislocated humeral head through the rotator interval via a deltopectoral approach that is frequently utilized for internal fixation of proximal humerus fractures and fracture dislocations. The sheath of the long head of biceps (LHB) and the rotator interval capsule are opened till the glenoid; this enables access to the glenohumeral joint via the rotator interval. A long-handle Cobb elevator is introduced through the rotator interval and, under intraoperative imaging, advanced posteromedially to the dislocated humeral head.
View Article and Find Full Text PDFJ Craniofac Surg
September 2025
Division of Ophthalmic Plastic and Reconstructive Surgery, Sadik Eratik Eye Institute, Haydarpasa Numune Education and Research Hospital, University of Health Sciences.
Orbital floor fractures can lead to enophthalmos and diplopia, often requiring surgical intervention to restore orbital volume. Autologous iliac bone grafts are commonly used due to their biocompatibility and mechanical stability, but achieving adequate fixation remains a challenge. Traditional fixation methods, such as plates and screws, may introduce risks of foreign body reactions, graft displacement, and surgical morbidity.
View Article and Find Full Text PDFFront Surg
August 2025
The First Affiliated Hospital of Hunan University of Chinese Medicine, Yuhua District, Changsha, Hunan, China.
Objective: To explore the clinical efficacy of internal fixation of locking compression plate and Cannulated Screw in treatment of elderly femoral neck fractures.
Methods: 175 patients with femoral neck fractures admitted to our hospital from January 2022 to December 2022 were enrolled in the study. 93 cases in the control group were treated with Cannulated Screw internal fixation, and 82 cases in the observation group were treated with locking plate internal fixation.
J Am Podiatr Med Assoc
September 2025
§Aybars Kıvrak Orthopedics Clinic, Adana, Turkey.
Background: Pilon fractures refer to distal tibial fractures that may involve extra-articular, partial articular, or complete intra-articular components, most commonly caused by high-energy trauma. The choice between early (<72 hours) and delayed (>7 days) surgical fixation significantly impacts clinical outcomes. This study aimed to compare the effects of early vs.
View Article and Find Full Text PDFComparative clinical efficacy of nickel-titanium shape memory staples versus miniplate for Bartoníček-Rammelt type III and IV posterior malleolar fractures. A retrospective analysis of 47 consecutive patients treated between January 2022 and June 2024 documented operative time, intraoperative blood loss, fluoroscopy times, healing time, complications, postoperative fracture gap distance (mm), and articular surface step-off (mm) at the ankle joint. Ankle function was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, the Manchester-Oxford Foot Questionnaire (MOXFQ), and range of motion measurements at 3, 6, 12, and 14 months.
View Article and Find Full Text PDF