Generative Adversarial Network-based Noncontrast CT Angiography for Aorta and Carotid Arteries.

Radiology

From the Department of Radiology, Chinese PLA General Hospital, 28 Fuxing Rd, Haidian District, Beijing 100853, China (J. Lyu, Y.X., Q.D., C.D., X.W., X.X., D.Z., J. Lin, C. Luo, X.M., X.B., J. Hu, C. Li, J. Huang, X.L.); College of Medical Technology, School of Computer Science and Technology, Beij

Published: November 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background Iodinated contrast agents (ICAs), which are widely used in CT angiography (CTA), may cause adverse effects in humans, and their use is time-consuming and costly. Purpose To develop an ICA-free deep learning imaging model for synthesizing CTA-like images and to assess quantitative and qualitative image quality as well as the diagnostic accuracy of synthetic CTA (Syn-CTA) images. Materials and Methods A generative adversarial network (GAN)-based CTA imaging model was trained, validated, and tested on retrospectively collected pairs of noncontrast CT and CTA images of the neck and abdomen from January 2017 to June 2022, and further validated on an external data set. Syn-CTA image quality was evaluated using quantitative metrics. In addition, two senior radiologists scored the visual quality on a three-point scale (3 = good) and determined the vascular diagnosis. The validity of Syn-CTA images was evaluated by comparing the visual quality scores and diagnostic accuracy of aortic and carotid artery disease between Syn-CTA and real CTA scans. Results CT scans from 1749 patients (median age, 60 years [IQR, 50-68 years]; 1057 male patients) were included in the internal data set: 1137 for training, 400 for validation, and 212 for testing. The external validation set comprised CT scans from 42 patients (median age, 67 years [IQR, 59-74 years]; 37 male patients). Syn-CTA images had high similarity to real CTA images (normalized mean absolute error, 0.011 and 0.013 for internal and external test set, respectively; peak signal-to-noise ratio, 32.07 dB and 31.58 dB; structural similarity, 0.919 and 0.906). The visual quality of Syn-CTA and real CTA images was comparable (internal test set, = .35; external validation set, > .99). Syn-CTA showed reasonable to good diagnostic accuracy for vascular diseases (internal test set: accuracy = 94%, macro F1 score = 91%; external validation set: accuracy = 86%, macro F1 score = 83%). Conclusion A GAN-based model that synthesizes neck and abdominal CTA-like images without the use of ICAs shows promise in vascular diagnosis compared with real CTA images. Clinical trial registration no. NCT05471869 © RSNA, 2023 . See also the editorial by Zhang and Turkbey in this issue.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.230681DOI Listing

Publication Analysis

Top Keywords

cta images
16
real cta
16
diagnostic accuracy
12
syn-cta images
12
visual quality
12
external validation
12
validation set
12
test set
12
images
9
generative adversarial
8

Similar Publications

Geometric changes in the sigmoid sinus diverticulum (SSD) can alter its hemodynamic - a primary factor contributing to pulsatile tinnitus (PT). However, not all SSD cases lead to clinical PT symptoms. This study aims to investigate the influence of the diameter of the diverticulum (EDD) on the hemodynamics of the sigmoid sinus in PT.

View Article and Find Full Text PDF

Patients with inflammation-associated coronary artery disease (CAD) may exhibit rapid progression and require regular coronary imaging. To evaluate the diagnostic performance of spectral photon-counting detector (PCD) coronary CTA with reduced radiation and contrast media doses for detecting coronary stenosis and in-stent restenosis in patients with inflammation-associated CAD. This prospective study enrolled patients with inflammation-associated CAD from January 2023 to March 2024.

View Article and Find Full Text PDF

Introduction: Primary central nervous system vasculitis (primary CNS vasculitis) is a rare inflammatory disorder that affects small-to-medium-sized cerebral vessels, often leading to recurrent strokes. Diagnosis is vague due to non-specific neurological symptoms. Imaging findings, cerebrospinal fluid (CSF) analysis and exclusion of systemic vasculitis are essential for diagnosis.

View Article and Find Full Text PDF

Background: Gluteus maximus (GMax) tenotomy is a well described technique to improve femoral and/or acetabular exposure during the Kocher Langenbeck approach. Branches of the first femoral perforator artery (1FPA) are frequently encountered and may be injured during the tenotomy, causing bleeding and obscuration of surgical field. The understanding of vascular anatomy around GMax insertion is poor.

View Article and Find Full Text PDF

Breast cancer is a highly heterogeneous disease with diverse outcomes, and intra-tumoral heterogeneity plays a significant role in both diagnosis and treatment. Despite its importance, the spatial distribution of intra-tumoral heterogeneity is not fully elucidated. Spatial transcriptomics has emerged as a promising tool to study the molecular mechanisms behind many diseases.

View Article and Find Full Text PDF