98%
921
2 minutes
20
Silicon monoxide (SiO) has attracted growing attention as one of the most promising anodes for high-energy-density lithium-ion batteries (LIBs), benefiting from relatively low volume expansion and superior cycling performance compared to bare silicon (Si). However, the size of the SiO particle for commercial application remains uncertain. Besides, the materials and concepts developed on the laboratory level in half cells are quite different from what is necessary for practical operation in full cells. Herein, we investigate the electrochemical performance of SiO with different particle sizes between half cells and full cells. The SiO with larger particle size exhibits worse electrochemical performance in the half cell, whereas it demonstrates excellent cycling stability with a high capacity retention of 91.3% after 400 cycles in the full cell. The reasons for the differences in their electrochemical performance between half cells and full cells are further explored in detail. The SiO with larger particle size possessing superior electrochemical performance in full cells benefits from consuming less electrolyte and not being easier to aggregate. It indicates that the SiO with larger particle size is recommended for commercial application and part of the information provided from half cells may not be advocated to predict the cycling performances of the anode materials. The analysis based on the electrochemical performance of the SiO between half cells and full cells gives fundamental insight into further Si-based anode research.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsami.3c01418 | DOI Listing |
Langmuir
September 2025
Key Laboratory of Functional Molecular Solids (Ministry of Education), College of Chemistry and Materials Science, Anhui Key Laboratory of Biomedical Materials and Chemical Measurement, Anhui Normal University, Wuhu 241000, China.
The sluggish kinetics and diffusion of lithium polysulfide (LiPS) intermediates lead to the decline in the capacity and rate of high-energy lithium-sulfur (Li-S) batteries. Integrating adsorbents and electrocatalysts into the Li-S system is an effective strategy for suppressing the polysulfide shuttle and enhancing the redox kinetics of sulfur species. The disordered structure of the electrocatalysts exhibits significantly enhanced catalytic activity.
View Article and Find Full Text PDFACS Nano
September 2025
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea.
Vagus nerve stimulation (VNS) is a promising therapy for neurological and inflammatory disorders across multiple organ systems. However, conventional rigid interfaces fail to accommodate dynamic mechanical environments, leading to mechanical mismatches, tissue irritation, and unstable long-term interfaces. Although soft neural interfaces address these limitations, maintaining mechanical durability and stable electrical performance remains challenging.
View Article and Find Full Text PDFInorg Chem
September 2025
College of Chemistry and Materials Science, The key Laboratory of Functional Molecular Solids, Ministry of Education, The Key Laboratory of Electrochemical Clean Energy of Anhui Higher Education Institutes, Anhui Provincial Engineering Laboratory for New-Energy Vehicle Battery Energy-Storage Materia
Conventional acid-catalyzed acetalization faces significant challenges in catalyst recovery and poses environmental concerns. Herein, we develop a CeO-supported Pd single-atom catalyst (Pd/CeO) that eliminates the reliance on liquid acids by creating a localized H-rich microenvironment through heterolytic H activation. X-ray absorption near-edge structure and extended X-ray absorption fine structure analyses confirm the atomic dispersion of Pd via Pd-O-Ce coordination, while density functional theory (DFT) calculations reveal strong metal-support interactions (SMSI) that facilitate electron transfer from CeO oxygen to Pd, downshifting the Pd d-band center and optimizing H activation.
View Article and Find Full Text PDFLangmuir
September 2025
Centre for Biomedical Engineering, Indian Institute of Technology, Delhi, New Delhi 110016, India.
The study addresses the critical issue of sepsis diagnosis, a life-threatening condition triggered by the body's immune response to infection that leads to mortality. Current diagnostic methods rely on the time-consuming assessment of multiple biomarkers by a series of tests, leading to delayed treatment. Here, we report a platform for developing a point-of-care (POC) device utilizing electrochemical immunosensors for the dual and rapid detection of sepsis biomarkers: Procalcitonin (PCT), Interleukin-6 (IL-6), and C-reactive protein (CRP) as host markers and lipopolysaccharide (LPS) as a pathogen marker.
View Article and Find Full Text PDFACS Sens
September 2025
Department of Pharmacy, The People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi Academy of Medical Sciences, Nanning, Guangxi 530021, China.
Alzheimer's disease (AD) is a progressive neurodegenerative disorder primarily characterized by cognitive decline and behavioral impairments, typically manifesting in the elderly and presenile population. With the rapid global aging trend, early diagnosis and treatment of AD have become increasingly urgent research priorities. The primary pathological features of AD include excessive accumulation of β-amyloid (Aβ) plaques, the formation of neurofibrillary tangles, and neuronal loss.
View Article and Find Full Text PDF