Isocyanates may contribute to allergic contact dermatitis from diabetes devices and wound dressings.

Contact Dermatitis

Department of Dermatology, University Hospital Antwerp (UZA) and Research Group Immunology, INFLA-MED Centre of Excellence, University of Antwerp, Antwerp, Belgium.

Published: November 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Isocyanates are well-known occupational allergens, but can also be present in medical devices.

Objectives: To highlight that contact sensitization to isocyanates might contribute to allergic contact dermatitis (ACD) from polyurethane (PU)-containing diabetes devices and wound dressings.

Patients And Methods: Nineteen patients with suspected ACD from diabetes devices and/or wound dressings were patch tested to an isocyanate series. Four wound dressings, six diabetes devices and four monomeric isocyanate patch test preparations were analysed with gas chromatography - mass spectrometry.

Results: Eight patients reacted to isocyanates and corresponding amines: 3 to isophorone diisocyanate (IPDI), 4 to 4,4'-diaminodiphenylmethane (MDA), 4 to 2,4-toluene diisocyanate (TDI) and 1 to polymeric methylene diphenyl diisocyanate (PMDI). Three of four wound dressings contained isocyanates (methylene diphenyl diisocyanate [MDI], TDI and/or IPDI), whereas five of six diabetes devices contained 4,4'-MDI, and one of them also IPDI. None of the medical devices contained 1,6-hexamethylene diisocyanate. Contrary to IPDI, and especially MDI, only the concentration of the TDI patch test preparation corresponded approximately (80%) to its label.

Conclusion: Patch tests with isocyanates may be worth-while in patients with suspected ACD from PU-containing medical devices. Besides MDA, and PMDI, also TDI might potentially be a marker for MDI-sensitization.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cod.14187DOI Listing

Publication Analysis

Top Keywords

diabetes devices
20
wound dressings
16
isocyanates contribute
8
contribute allergic
8
allergic contact
8
contact dermatitis
8
devices wound
8
patients suspected
8
suspected acd
8
patch test
8

Similar Publications

Glucose sensors are critical analytical devices designed for precise and continuous monitoring of glucose concentrations, playing a pivotal role in healthcare, particularly in diabetes management. Here, we synthesis glucose oxidase (GOx)/Se hydrogel to detect the glucose, thereby generating measurable electrical signals. Further, the transfection of electronic signals rely on the poly(dopamine) (PDA) grid in hydrogel.

View Article and Find Full Text PDF

Effect of henagliflozin on aging biomarkers in patients with type 2 diabetes: A multicenter, randomized, double-blind, placebo-controlled study.

Cell Rep Med

August 2025

Department of Endocrinology and Metabolism, First Affiliated Hospital of Nanchang University, Nanchang, Jiangxi 330006, People's Republic of China; Jiangxi Clinical Research Center for Endocrine and Metabolic Disease, Nanchang, Jiangxi 330006, People's Republic of China; Jiangxi Branch of National C

Sodium-glucose cotransporter-2 inhibitors have been proposed as caloric restriction mimetics with potential anti-aging effects. However, clinical data on their influence on aging biomarkers are limited. In this multicenter, randomized, double-blind, placebo-controlled trial, 150 participants with type 2 diabetes are randomized (1:1) to receive oral henagliflozin (10 mg/day) or placebo for 26 weeks.

View Article and Find Full Text PDF

Objective: This study presents a comprehensive analysis of electrochemical skin conductance (ESC) values collected from over 1.9 million measurements using Withings Body Scan and Body Comp scales. It aimed at establishing descriptive values for ESC while correcting for the influence of age, sex, and circadian and seasonal variations on sudomotor function.

View Article and Find Full Text PDF

Wearable Point-of-Care Biosensor for Biomolecular Assay in Health Monitoring.

ACS Appl Bio Mater

September 2025

Department of Toxicology and Sanitary Chemistry, School of Public Health, Capital Medical University, Beijing 100069, P.R. China.

Wearable biosensors represent a significant advancement in preventive health monitoring by enabling early disease detection through real-time bioanalysis. This review examines the evolution of point-of-care testing (POCT), with a focus on materials, fabrication techniques, and real-world applications. These biosensors utilize advanced materials, such as supramolecular hydrogels, and innovative manufacturing methods, providing high sensitivity, specificity, and portability.

View Article and Find Full Text PDF

Upscaling, toxicity and efficacy of multifaceted dressing embedded with dsirna-loaded gold nanoparticles for enhancing diabetic wound treatment.

PLoS One

September 2025

Faculty of Pharmacy, Centre for Drug Delivery Technology and Vaccine (CENTRIC), Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, Kuala Lumpur, Malaysia.

Poor vascularization and infections hinder diabetic wound healing, posing challenges in therapy development. A multi-action approach incorporating Dicer-substrate small interfering RNA (DsiRNA) against the prostaglandin transporter (PGT) gene and gold nanoparticles (AuNPs) into a Pluronic F-127 (PF127) gel was developed. This study aimed to upscale AuNP biosynthesis using Lignosus rhinocerotis (tiger milk mushroom, TMM) extract and chitosan as stabilizers.

View Article and Find Full Text PDF