The performance of a visual guidance patient-controlled (VG-PC) respiratory gating system for magnetic-resonance (MR) image-guided radiation therapy (MR-IGRT) was evaluated through a clinical trial of patients with either lung or liver cancer. Patients can voluntarily control their respiration utilizing the VG-PC respiratory gating system. The system enables patients to view near-real-time cine planar MR images projected inside the bore of MR-IGRT systems or an external screen. Twenty patients who had received stereotactic ablative radiotherapy (SABR) for lung or liver cancer were prospectively selected for this study. Before the first treatment, comprehensive instruction on the VG-PC respiratory gating system was provided to the patients. Respiratory-gated MR-IGRT was performed for each patient with it in the first fraction and then without it in the second fraction. For both the fractions, the total treatment time, beam-off time owing to the respiratory gating, and number of beam-off events were analyzed. The average total treatment time, beam-off time, and number of beam-off events with the system were 1507.3 s, 679.5 s, and 185, respectively, and those without the system were 2023.7 s (p < 0.001), 1195.0 s (p < 0.001), and 380 times (p < 0.001), respectively. The VG-PC respiratory gating system improved treatment efficiency through a reduction in the beam-off time, the number of beam-off events, and consequently the total treatment time when performing respiratory-gated MR-IGRT for lung and liver SABR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s13246-022-01144-0 | DOI Listing |
JACC Case Rep
September 2025
Department of Radiology, Saint Louis University School of Medicine, St Louis, Missouri, USA. Electronic address:
Background: Ventricular pseudoaneurysm formation due to longstanding lead erosion is rare, and standardized guidelines for diagnosis and management are limited.
Case Summary: We present a case of a right ventricular pseudoaneurysm noted on computed tomography after a patient with a pacemaker, originally placed in 2013, was admitted for respiratory failure. PolyJet three-dimensional printing was employed to assist in presurgical planning and evaluating the spatial anatomic relationship of the lead to the ventricular outpouching.
Radiol Phys Technol
September 2025
Radiation and Proton Therapy Center, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-Cho, Shizuoka, 411-8777, Japan.
In therapy with Synchrony® mounted on Radixact®, the fiducial marker (FM) and adrenal gland metastasis, which shift with respiratory phase, require margin compensation for high-dose prescriptions. Although compensation is critical, no studies have examined the margin to compensate for the respiratory phase shift. Therefore, we aimed to suggest the compensating margin for the FM and adrenal metastasis shift along with respiratory phase.
View Article and Find Full Text PDFJ Pediatr Surg
September 2025
Department of Biomedical Engineering, University of Cincinnati, Cincinnati, USA; Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, USA; Department of Pediatrics, University of Cincinnati, Cincinnati, USA; Department of Radiology, Cincinnati Children's Hospita
Introduction: Tracheoesophageal fistula (TEF), often occurring with esophageal atresia (EA), presents significant respiratory challenges in neonates. Neither the effect of EA/TEF, nor the effect of post-surgical complications such as tracheomalacia, on respiratory effort has been previously quantified. This study calculates the tracheal resistive component of work of breathing (TR-WOB) to quantify breathing effort pre- and post-surgical repair of EA/TEF.
View Article and Find Full Text PDFMed Phys
August 2025
Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
Background: Low-field MRI provides superior soft-tissue contrast compared to CT while costing significantly less than high-field MRI, which makes it a more accessible option for MRI-guided radiation therapy planning. Four-dimensional MRI (4D-MRI) is a technique that has been increasingly adopted clinically for internal target volume (ITV) delineation in free-breathing liver radiotherapy planning, and it requires high spatial resolution and accurate respiratory phase differentiation to enable precise dose planning. The feasibility of 4D-MRI at low-field strength, specifically at 0.
View Article and Find Full Text PDFMater Today Bio
October 2025
Department of Chemistry and Chemical Engineering, Inner Mongolia University, Hohhot, 010020, China.
MicroRNAs (miRNAs) play a critical role in early cancer detection, but traditional DNA probes are limited by the low abundance of miRNAs and their "always effective" property. Herein, we construct a photocaged amplified DNA nanodevice (PAD) by attaching DNA probes to upconversion nanoparticles (UCs). Upon remote near-infrared (NIR) light stimulation, the photocleavable DNA probes are activated by emitted UV light, and subsequently triggered by target miRNA.
View Article and Find Full Text PDF