Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The rate of transvenous lead extraction (TLE) is increasing, with an increasing rate of complex devices being implanted. TLE is now a routine part of cardiac device management and up-to-date data on the safety and efficacy of TLE with modern tools and techniques is essential to management decisions regarding noninfectious indications for lead extraction. We present a contemporary, prospective review of TLE at our high-volume cardiac center. All patients who underwent TLE from June 2016 to June 2019 were enrolled in our local database, and baseline clinical data, procedural information, and outcome data were collected. In total, 561 leads were explanted (n = 153) or extracted (n = 408) from 341 patients over the study period. Patients were predominantly male (71%), with a mean age of 65 ± 17 years. The most common indication for lead removal was lead failure (45.2%, n = 154), followed by infection of the pocket or device (29.3%, n = 100). In total, complete success was achieved in 96.4% (n = 541) leads, clinical success in a further 2.1% (n = 12), and failure only in 1.4% (n = 8). There was an overall complication rate of 0.9% (3/341) for major complications and 1.5% (5/341) for minor complications. There were no deaths. In conclusion, our data suggest that there are ongoing improvements in the safety profile and success rates of lead extraction undertaken by experienced operators. The major complication rate now is <1%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2022.04.022DOI Listing

Publication Analysis

Top Keywords

lead extraction
16
complication rate
8
lead
6
tle
5
patient characteristics
4
characteristics procedural
4
procedural characteristics
4
characteristics outcomes
4
patients
4
outcomes patients
4

Similar Publications

Management of Transvenous Leads in Patients With Iatrogenic Lead Perforation.

J Cardiovasc Electrophysiol

September 2025

Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.

Introduction: Iatrogenic lead perforation is a rare but serious complication of cardiac implantable electronic device (CIED) implantation. Evidence on percutaneous management of subacute or delayed cases remains limited.

Methods: We retrospectively reviewed 38 patients treated for iatrogenic lead perforation between January 2012 and October 2024.

View Article and Find Full Text PDF

Lignin-intercalated WS with synergistic adsorption for efficiency lead removal.

Bioresour Technol

September 2025

School of Agricultural Engineering and Food Science, Shandong University of Technology, Zibo 255000, China; Zibo Engineering Research Center for Bio-based New Materials, Zibo 255000, China. Electronic address:

Tungsten disulfide (WS), a two-dimensional adsorbent material, has garnered great attention in removing lead ions (Pb) from water due to their extensive exposed adsorption sites. However, WS nanosheets inevitably agglomerated and stacked during the preparation and adsorption process, leading to reduced adsorption efficiency. Current method of enhancing WS dispersion is mainly blending with synthetic polymers, but these synthetic polymers themselves do not possess adsorption properties, resulting adsorption effect enhancement poorly.

View Article and Find Full Text PDF

The safe disposal of heavy metal elements (Pb, Zn, Cu, etc.) in copper smelting slag and efficient treatment of phosphogypsum are urgent. To explore the feasibility of co-processing copper smelting slag and phosphogypsum, this study used PbO and CaSO as raw materials to investigate the sulfidation roasting process and flotation separation of roasted products.

View Article and Find Full Text PDF

The correlation between Pb species formation and bioaccessibility in alkaline, smelter-impacted soil co-contaminated with other toxic trace elements after treatment with phosphorus-containing amendments was investigated. The soil was collected near a former copper smelter, El Paso, Texas. It contained Pb (3200 ± 142 mg kg), As (254 ± 14 mg kg), and Cd (110 ± 8 mg kg).

View Article and Find Full Text PDF

Incorporating bioaccessibility into health risk assessments enhances the accuracy of exposure estimates for heavy metal (HM) pollution, supports targeted remediation, and informs public health and policy decisions, particularly for vulnerable populations. Because HM bioaccessibility depends on local soil and geographic characteristics, identifying its relationship with soil properties is crucial for assessing soil pollution potential. Although HM concentrations can be measured relatively easily, bioaccessibility requires complex laboratory procedures, limiting routine applications in regulatory contexts.

View Article and Find Full Text PDF