[Development and Application of Automatic Analysis and Surveillance Platform for Chrimerism in Donors and Recipients after Allo-HSCT].

Zhongguo Shi Yan Xue Ye Xue Za Zhi

Department of Internal Medicine Teaching and Research Section of Henan Medical College, Zhengzhou 451191, Henan Province, China,Beijing LU Dao-Pei Institute of Hematology, Beijing 100176, China,Department of Pathology & Laboratorial Medicine, Beijing LU Dao-Pei Hospital, Beijing 100176, China,E-mail

Published: June 2020


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To develop an automated chimeric analysis and reporting platform based on short tandem repeat (STR) and capillary electrophoresis methods for allogeneic hematopoietic stem cell transplantation (allo-HSCT) so as to improve work efficiency.

Methods: Apache, MySQL, PHP and HTML5 were used to build the database and interface. The STR locus geno typing and chimeric analysis logic and flow were set up on the basis of STR rules and capillary electrophoresis. STR genotyping and 194 times of chimeric testing data of 100 patients after allo-HSCT were used to test the platform for automatic STR locus genotyping, chimeric calculation and report generation.

Results: The established platform could realize the functions of STR locus customization, STR genotype determination, automatic chimeric analysis, and detection information database management, which can automatically generate an integrated report including multiple sequential chimeric results and trend graphs for the same patient and can be accessed and used simultaneously by different users through different browser interfaces. The results of automated analysis by the platform are completely consistent with that of manual analysis by experienced technicians, and the possibility of manual analysis error is reduced through automation. The time required for automatic analysis using this platform is approximately 1/6-1/5 of manual analysis.

Conclusion: The automatic analysis platform built in this study is operation stable and reliable in analysis results, which can improve work efficiency and report connotation, thus worthing popularized and applicable.

Download full-text PDF

Source
http://dx.doi.org/10.19746/j.cnki.issn.1009-2137.2020.03.049DOI Listing

Publication Analysis

Top Keywords

automatic analysis
12
chimeric analysis
12
str locus
12
analysis platform
12
analysis
10
capillary electrophoresis
8
improve work
8
manual analysis
8
platform
7
str
7

Similar Publications

The aim of the study was to validate a new method for semiautomatic subtraction of [Tc]Tc-sestamibi and [Tc]NaTcO SPECT 3-dimensional datasets using principal component analysis (PCA) against the results of parathyroid surgery and to compare its performance with an interactive method for visual comparison of images. We also sought to identify factors that affect the accuracy of lesion detection using the two methods. Scintigraphic data from [Tc]Tc-sestamibi and [Tc]NaTcO SPECT were analyzed using semiautomatic subtraction of the 2 registered datasets based on PCA applied to the region of interest including the thyroid and an interactive method for visual comparison of the 2 image datasets.

View Article and Find Full Text PDF

Autonomous agents powered by Large Language Models are transforming AI, creating an imperative for the visualization area. However, our field's focus on a human in the sensemaking loop raises critical questions about autonomy, delegation, and coordination for such agentic visualization that preserve human agency while amplifying analytical capabilities. This paper addresses these questions by reinterpreting existing visualization systems with semi-automated or fully automatic AI components through an agentic lens.

View Article and Find Full Text PDF

Brain activation for language and its relationship to cognitive and linguistic measures.

Cereb Cortex

August 2025

Faculty of Psychology and Education Science, Department of Psychology, University of Geneva, Chemin des Mines 9, Geneva, 1202, Switzerland.

Language learning and use relies on domain-specific, domain-general cognitive and sensory-motor functions. Using fMRI during story listening and behavioral tests, we investigated brain-behavior associations between linguistic and non-linguistic measures in individuals with varied multilingual experience and reading skills, including typical reading participants (TRs) and dyslexic readers (DRs). Partial Least Square Correlation revealed a main component linking cognitive, linguistic, and phonological measures to amodal/associative brain areas.

View Article and Find Full Text PDF

Objective: This study aimed to create and validate a nomogram to predict early recurrence (ER) in Colorectal cancer (CRC) patients by combining CT-derived abdominal fat parameters with clinical and pathological characteristics.

Methods: We conducted a retrospective analysis of 206 CRC patients, dividing them into training (n = 146) and validation (n = 60) cohorts. We quantified abdominal fat parameters, including subcutaneous adipose tissue index (SATI) and visceral adipose tissue index (VATI), using semi-automatic software on CT images at the level of the third lumbar vertebra (L3).

View Article and Find Full Text PDF

AI Model Based on Diaphragm Ultrasound to Improve the Predictive Performance of Invasive Mechanical Ventilation Weaning: Prospective Cohort Study.

JMIR Form Res

September 2025

Department of Critical Care Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangdong Provincial Geriatrics Institute, No. 106, Zhongshaner Rd, Guangzhou, 510080, China, 86 15920151904.

Background: Point-of-care ultrasonography has become a valuable tool for assessing diaphragmatic function in critically ill patients receiving invasive mechanical ventilation. However, conventional diaphragm ultrasound assessment remains highly operator-dependent and subjective. Previous research introduced automatic measurement of diaphragmatic excursion and velocity using 2D speckle-tracking technology.

View Article and Find Full Text PDF