Article Abstract

Objective Compare the concordance degree between plasma glucose and glucose measurements on Dried Blood Spots (DBS) during pregnancy. Subjects and methods Glucose measurement was performed in pregnant women after a fast of 8-12 hours. Venous blood was collected with sodium fluoride, the plasma was separated, and glucose measured by the enzymatic oxidase glucose method. Capillary blood samples were collected and analyzed by DBS. For statistics, the paired Student's t test, interclass correlation coefficient (ICC), graphic approach of Altman and Bland, and survival - concordance plot were used. Results 307 pregnant women were evaluated, 88.6% without diabetes and 11.4% with previous diabetes. The glucose ranged from 66 to 190 mg/dL [3.66 to 10.55 mmol/L] in plasma and from 53 to 166 mg/dL [2.94 to 9.21 mmol/L] in DBS. The glucose average values were 88.1 ± 12 mg/dL [4.98 ± 0.67 mmol/L] in plasma and 89.2 ±11,5 mg/dL, [4.95 ± 0.64 mmol/L] in DBS - p-value = 0.084. The ICC value was moderate (0.510), and Pearson's correlation coefficient was r = 0.507 p < 0.001. Altman and Bland's graph showed that difference between the values obtained by both methods is -24.62 to 22.3 mg/dL [-1.37 to 1.24 mmol/L]. Significant fixed bias (-1,16 average difference) and proportional bias (r = 0.056; p = 0.33) were not observed. Anemia was associated with differences between plasma glucose and DBS measurements (p = 0.031). Conclusion Capillary glucose in DBS correlates with plasma glucose; however, the methods do not present good concordance. The presence of anemia worsens this result.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10522073PMC
http://dx.doi.org/10.20945/2359-3997000000229DOI Listing

Publication Analysis

Top Keywords

pregnant women
12
plasma glucose
12
glucose
10
glucose measurement
8
dried blood
8
blood spots
8
correlation coefficient
8
mmol/l] plasma
8
mmol/l] dbs
8
glucose dbs
8

Similar Publications

Background: During pregnancy, significant physiological, morphological, and hormonal changes profoundly affect women's biomechanics, increasing the risk of falls and musculoskeletal complaints, especially in the third trimester. To understand movement adaptations and musculoskeletal disorders in pregnant women, kinetic analysis using pregnant-specific multi-segment or musculoskeletal models is essential. This review aims to evaluate the development, applications and limitations of such models intended for kinetic analysis in pregnancy.

View Article and Find Full Text PDF

A prospective study of physical activity in full-term pregnant women and its effect on pregnancy outcomes.

Eur J Obstet Gynecol Reprod Biol

September 2025

Women's Hospital, School of Medicine, Zhejiang University, Hangzhou, China. Electronic address:

Background: The effects of physical activity (PA), especially brisk walking, on labor outcomes and pregnancy health have not been clearly established. This study aimed to investigate the relationship between PA and cervical ripeness and pregnancy outcomes in term pregnant women.

Basic Procedures: A prospective cohort study was conducted with 52 pregnant women (30.

View Article and Find Full Text PDF

Assessing psychological trauma levels and contributory factors among pregnant women following seismic events.

J Health Psychol

September 2025

Department of Obstetrics and Gynecology Nursing, Balcalı Campus, Çukurova University Faculty of Health Sciences, Sarıçam, Adana, Türkiye.

This study aimed to examine post-earthquake psychological trauma and its contributing factors among pregnant women who were exposed to the large-scale twin earthquakes that occurred on February 6, 2023, in Türkiye. This cross-sectional study was conducted with 5227 pregnant women and found that 72.2% experienced post-earthquake psychological trauma following the earthquakes, including behavioral, sleep-related, emotional, and cognitive symptoms.

View Article and Find Full Text PDF

Objectives: To determine the discriminatory capacity of maternal ophthalmic artery (OA) Doppler parameters at 18-24 weeks of gestation for predicting pre-eclampsia (PE) in a south Indian population and to compare its predictive ability with known markers of pre-eclampsia like mean arterial pressure (MAP) and uterine artery pulsatility index (UtA-PI).

Methods: This was a single-center prospective observational study of normotensive pregnant women presenting for routine ultrasound screening between 18 and 24 weeks of gestation. OA and UtA Doppler were performed on all enrolled participants who were followed up for subsequent development of PE.

View Article and Find Full Text PDF

Background: Hemoglobin estimation (Hb) is the most requested hematology test, especially among pregnant/postnatal women and people living with HIV (PLHIV). In Uganda, several point-of-care (POC) Hb testing devices are currently used and performance may be affected by multiple factors. This study evaluated the diagnostic and analytic performance of four Hb POC devices.

View Article and Find Full Text PDF