98%
921
2 minutes
20
Background: Cardiovascular resonance (CMR) imaging is a standard imaging modality for assessing cardiovascular diseases (CVDs), the leading cause of death globally. CMR enables accurate quantification of the cardiac chamber volume, ejection fraction and myocardial mass, providing information for diagnosis and monitoring of CVDs. However, for years, clinicians have been relying on manual approaches for CMR image analysis, which is time consuming and prone to subjective errors. It is a major clinical challenge to automatically derive quantitative and clinically relevant information from CMR images.
Methods: Deep neural networks have shown a great potential in image pattern recognition and segmentation for a variety of tasks. Here we demonstrate an automated analysis method for CMR images, which is based on a fully convolutional network (FCN). The network is trained and evaluated on a large-scale dataset from the UK Biobank, consisting of 4,875 subjects with 93,500 pixelwise annotated images. The performance of the method has been evaluated using a number of technical metrics, including the Dice metric, mean contour distance and Hausdorff distance, as well as clinically relevant measures, including left ventricle (LV) end-diastolic volume (LVEDV) and end-systolic volume (LVESV), LV mass (LVM); right ventricle (RV) end-diastolic volume (RVEDV) and end-systolic volume (RVESV).
Results: By combining FCN with a large-scale annotated dataset, the proposed automated method achieves a high performance in segmenting the LV and RV on short-axis CMR images and the left atrium (LA) and right atrium (RA) on long-axis CMR images. On a short-axis image test set of 600 subjects, it achieves an average Dice metric of 0.94 for the LV cavity, 0.88 for the LV myocardium and 0.90 for the RV cavity. The mean absolute difference between automated measurement and manual measurement is 6.1 mL for LVEDV, 5.3 mL for LVESV, 6.9 gram for LVM, 8.5 mL for RVEDV and 7.2 mL for RVESV. On long-axis image test sets, the average Dice metric is 0.93 for the LA cavity (2-chamber view), 0.95 for the LA cavity (4-chamber view) and 0.96 for the RA cavity (4-chamber view). The performance is comparable to human inter-observer variability.
Conclusions: We show that an automated method achieves a performance on par with human experts in analysing CMR images and deriving clinically relevant measures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6138894 | PMC |
http://dx.doi.org/10.1186/s12968-018-0471-x | DOI Listing |
J Cereb Blood Flow Metab
September 2025
Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA, USA.
Preclinical PET studies offer the opportunity to elucidate molecular mechanisms underlying early neurodevelopment with minimal invasiveness. We demonstrated the feasibility of fetal brain PET in four pregnant rats ( = 42 fetuses). [F]FDG uptake in rat fetuses was readily visualized by PET imaging.
View Article and Find Full Text PDFZhong Nan Da Xue Xue Bao Yi Xue Ban
May 2025
Department of Rheumatology and Immunology, Xiangya Hospital, Central South University, Changsha 410008.
Objectives: Patients with connective tissue diseases (CTD) have a high incidence of cardiac involvement, which often presents insidiously and can progress rapidly, making it one of the leading causes of death. Multiparametric cardiovascular magnetic resonance (CMR) provides a comprehensive quantitative evaluation of myocardial injury and is emerging as a valuable tool for detecting cardiac involvement in CTD. This study aims to investigate the correlations between CMR features and serological biomarkers in CTD patients, assess their potential clinical value, and further explore the impact of pre-CMR immunotherapy intensity on CMR-specific parameters, thereby evaluating the role of CMR in the early diagnosis of CTD-related cardiac involvement.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
September 2025
Bosch Health Campus, Robert Bosch Hospital, Department of Cardiology and Angiology, Stuttgart, Germany.
Aims: For many years, visual assessment has been the mainstay of detecting obstructive coronary artery disease (CAD) by stress perfusion cardiovascular magnetic resonance (S-CMR). Recently, fully automated quantitative assessment of myocardial blood flow (MBF) has been introduced. The value of MBF quantification in patients with coronary chronic total occlusion (CTO) is unknown.
View Article and Find Full Text PDFJ Cardiovasc Magn Reson
September 2025
Royal Brompton and Harefield Hospitals, part of Guy's and St Thomas' NHS Foundation Trust, London, UK; National Heart and Lung Institute, Imperial College London, UK. Electronic address:
Background: Serial perfusion cardiovascular magnetic resonance (CMR) in symptomatic patients undergoing coronary artery bypass grafting (CABG) may provide mechanistic insight into dynamic abnormalities of the myocardium.
Objectives: To assess how changes in cardiac reperfusion and remodelling associate with symptom improvement in patients undergoing CABG METHODS: Patients awaiting elective CABG completed serial quality of life questionnaires and detailed CMR at baseline and at 6-12 months post CABG as per protocol. Automated fully quantitative stress and rest myocardial blood flow was calculated, alongside assessment of the visual ischaemic burden.
J Cardiovasc Magn Reson
September 2025
Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA; Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA.
Background: Although a recently developed wideband perfusion sequence has shown diagnostically acceptable image quality and accurate myocardial blood flow (MBF) quantification at rest in patients with cardiac implanted electronic devices (CIEDs), its performance during vasodilator stress remains unproven. This study aims to determine whether the sequence produces diagnostically acceptable image quality during stress and is capable of quantitatively detecting abnormal stress MBF and myocardial perfusion reserve (MPR) in patients with implanted cardiodefibrillators (ICDs).
Methods: We enrolled 29 patients with an ICD (mean age = 63 ± 15 years, 17 males, 12 females) and 11 control patients (mean age = 50 ± 17 years, 6 males, 5 females; negative coronary artery disease; negative stress perfusion CMR; and no cardiac event one year post CMR) with an ICD taped below the left clavicle to mimic image artifacts.