Article Abstract

A simple and sensitive biosensor array based on phosphorescence detection that is able to detect oxygen and glucose in human serum, respectively, has been developed. We demonstrate an electrochemical method as a fast, effective, tunable, and versatile means of growing phosphorescence sensing material. This sensing material, crystalline iridium(III)-Zn(II) coordination polymers, namely Ir-Zn(e), was grown on a stainless steel mesh and then doped in a sol-gel matrix. The emission of Ir-Zn(e) was ascribed to a metal-to-ligand charge transfer transition (MLCT). The noteworthy oxygen-sensing properties of Ir-Zn(e) were also evaluated. The optimal oxygen-sensing conditions of Ir-Zn(e) with a deduced K(SV) value of 3.55 were 5 V and 30 °C for 1 hour. Moreover, the short response time (23 s) and the recovery time (21 s) toward oxygen have been measured. The reversibility experiment was carried out for eleven cycles. The resulting >70% recovery of intensity for Ir-Zn(e) on each cycle demonstrated a high degree of reproducibility during the sensing process. The detection limit could be 0.050% for gaseous oxygen. The sensing substrate was subsequently built up under glucose oxidase encapsulated in hydrogel and then immobilized on an egg membrane by the layer-by-layer method. Once the glucose solution was injected into this array, oxygen content depleted simultaneously with a concomitant increase in the phosphorescence of coordination polymers. The linear dynamic range for the determination of glucose was 0.1-6.0 mM, the correlation coefficient (R(2)) was 0.9940 (y = 0.75 [glucose] + 0.539), and the response time was less than 120 s. The minimum detectable concentration for glucose was calculated to be 0.05 mM from three times signal to noise. The photophysical properties of the sensing material and the effects of buffer concentration, pH, interference, matrix effect, temperature, and the stability of the biosensor array have also been studied in detail. The biosensor array was successfully applied to the determination of glucose in human serum.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c3dt53504eDOI Listing

Publication Analysis

Top Keywords

biosensor array
12
sensing material
12
oxygen glucose
8
glucose human
8
human serum
8
coordination polymers
8
response time
8
determination glucose
8
glucose
7
sensing
6

Similar Publications

Simulations in three dimensions and time provide guidance on implantable, electroenzymatic glutamate sensor design; relative placement in planar sensor arrays; feasibility of sensing synaptic release events; and interpretation of sensor data. Electroenzymatic sensors based on the immobilization of oxidases on microelectrodes have proven valuable for the monitoring of neurotransmitter signaling in deep brain structures; however, the complex extracellular milieu featuring slow diffusive mass transport makes rational sensor design and data interpretation challenging. Simulations show that miniaturization of the disk-shaped device size below a radius of ∼25 μm improves sensitivity, spatial resolution, and the accuracy of glutamate concentration measurements based on calibration factors determined .

View Article and Find Full Text PDF

The development of sensors for monitoring breath acetone, a key biomarker for ketosis in diabetes mellitus, represents a critical frontier in medical diagnostics, promising a painless alternative to invasive blood tests. This review provides a comprehensive and critical evaluation of the state-of-the-art in acetone gas sensing technologies, including chemiresistive, optical, electrochemical, conductometric, and microwave platforms. We focus specifically on recent breakthroughs driven by advanced materials, analyzing how novel nanostructures from two-dimensional (2D) materials such as MXenes to porous metal-organic frameworks (MOFs) are engineered to push performance to clinically relevant parts-per-billion (ppb) sensitivity.

View Article and Find Full Text PDF

Liquid-phase suspension array technology (SAT), based on optically encoded microspheres, overcomes limitations of traditional enzyme-linked immunosorbent assay (ELISA) and chemiluminescence detection techniques via meeting high-throughput and multiplexing demands in biosensing and diagnosis. It demonstrates significant advantages in terms of accuracy, speed, sensitivity, and multiplex detection capabilities, and has become an emerging research hotspot in the field of luminescent immunodiagnostics. With rapid advancement of nanotechnology and multi-functional nanomaterials, liquid-phase suspension array chips have achieved remarkable progresses in multiplex analysis capacity, encoding capacity, encoding efficiency, detection sensitivity, decoding methods, and application fields.

View Article and Find Full Text PDF

Redox-Active Polyphenol Red Molecularly Imprinted Polymers on Porous Gold Electrodes for Ultrasensitive, AI-Assisted Detection of Alzheimer's Biomarkers in Undiluted Biofluids.

Adv Healthc Mater

September 2025

David Price Evans Global Health and Infectious Diseases Group, Pharmacology & Therapeutics, Institute of Systems Molecular and Integrative Biology, University of Liverpool, Crown Street, Liverpool, L69 7BE, UK.

Early diagnosis of Alzheimer's disease (AD) is hindered by the high cost, complexity, and centralization of current diagnostic platforms such as enzyme-linked immunosorbent assay (ELISA) and single-molecule array (SIMOA). Here, an integrated point-of-care (PoC) biosensing platform is reported based on redox-active polyphenol red molecularly imprinted polymers (pPhR MIPs) deposited on highly porous gold (HPG) electrodes for the ultrasensitive, reagent-free detection of phosphorylated tau 181 (p-tau 181) in undiluted plasma and serum. The unique electrochemical interface combines the signal-enhancing properties of HPG with the redox functionality of pPhR, eliminating the need for external redox probes.

View Article and Find Full Text PDF

Single-Electrode High-Throughput Dual-Color Electrochemiluminescence Array Biosensor: Portable Parallel Screening of Marine Pathogens.

Anal Chem

September 2025

Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China.

To achieve high-throughput rapid monitoring of marine pathogens, this study developed an innovative single-electrode electrochemiluminescence (SEE) array biosensing imaging platform. For the first time, the highly luminous RuSiO-Au and Lu@MIL-NH with a strong nanoconfinement effect were integrated onto a single 10-well microelectrode array. By taking advantage of the extremely strong ECL signals, red-blue dual-color ECL imaging detection of and was achieved, which can be clearly distinguished by the naked eye on mobile phones.

View Article and Find Full Text PDF