Undulation contributions to the area compressibility in lipid bilayer simulations.

Biophys J

Theoretical Biological Physics, Department of Theoretical Physics, Royal Institute of Technology (KTH), AlbaNova University Center, Stockholm, Sweden.

Published: November 2009


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

It is here shown that there is a considerable system size-dependence in the area compressibility calculated from area fluctuations in lipid bilayers. This is caused by the contributions to the area fluctuations from undulations. This is also the case in experiments. At present, such a contribution, in most cases, is subtracted from the experimental values to obtain a true area compressibility. This should also be done with the simulation values. Here, this is done by extrapolating area compressibility versus system size, down to very small (zero) system size, where undulations no longer exist. The area compressibility moduli obtained from such simulations do not agree with experimental true area compressibility moduli as well as the uncorrected ones from contemporary or earlier simulations, but tend, instead, to be approximately 50% too large. As a byproduct, the bending modulus can be calculated from the slope of the compressibility modulus versus system-size. The values obtained in this way for the bending modulus are then in good agreement with experiment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2776294PMC
http://dx.doi.org/10.1016/j.bpj.2009.08.048DOI Listing

Publication Analysis

Top Keywords

area compressibility
24
area
8
contributions area
8
area fluctuations
8
true area
8
system size
8
compressibility moduli
8
bending modulus
8
compressibility
7
undulation contributions
4

Similar Publications

Objectives: To evaluate whether q-Dixon sequence-based fat fraction (FF) values of the lumbar spine can predict osteoporotic vertebral compression fracture (OVCF) risk in older adult(s) osteoporosis patients.

Materials & Methods: Thirty OVCF patients and 15 osteoporosis patients were enrolled. Areas of interest (ROIs) were manually drawn using the post-processing workstation, and FF values of the patient's L1-L4 vertebrae (except the fractured vertebrae) were measured.

View Article and Find Full Text PDF

Electromagnetic pollution poses significant risks to electronic devices and human health, highlighting the need for mechanically robust, lightweight, and cost-effective electromagnetic interference (EMI) shielding materials. 3D-printed structures with nanomaterial-engineered surfaces offer a promising method for tailoring mechanical and electrical properties through multiscale design. Herein, we present a facile strategy for fabricating lightweight and flexible EMI shielding structures by chemical deposition of nanostructured metal coatings onto 3D-printed polymeric substrates.

View Article and Find Full Text PDF

Experimental study on identifying catastrophic failure in the brittle fracture process via multi-source acoustic characteristics.

Ultrasonics

September 2025

Faculty of Land Resource Engineering, Kunming University of Science and Technology, Yunnan 650093, China; Key Laboratory of Geohazard Forecast and Geoecological Restoration in Plateau Mountainous Area, Ministry of Natural Resources of the People's Republic of China, Yunnan Province, Kunming, Yunnan

Identifying and predicting the catastrophic failure of brittle rock remains a challenging task, yet it is crucial for developing early warning systems and preventing dynamic rock hazards. In this study, we employed the propagative parameters of ultrasonic waves and information from acoustic emission (AE) events to characterize the brittle failure of a flawed sandstone sample under uniaxial compression. A sliding event window method was developed to obtain the temporal b-value, effectively revealing microcrack growth based on the frequency-magnitude distribution of AE events.

View Article and Find Full Text PDF

Botulinum toxin injection of the piriformis muscle for refractory pudendal neuralgia after decompression surgery: case report.

Pain Manag

September 2025

Serviço de Reabilitação de Adultos 3, Centro de Medicina de Reabilitação de Alcoitão, Alcabideche, Portugal.

Pudendal neuropathy is a cause of pelvic pain, specifically pudendal neuralgia. The pudendal nerve is related to sensory, motor, and autonomic functions. We present the case of a 41-year-old man who suffered from chronic pelvic pain.

View Article and Find Full Text PDF

Despite significant advancements in aerogels science, the fabrication of high-performance aerogels with their plastic processability remains unexplored owing to their inherent trade-off between skeletal rigidity and transformable processability. Herein, a universal solubility-pKa coupling-effect to engineer high-performance thermoplastic nylon aerogel family with excellent thermomechanical processing performance is proposed. By modulating solubility parameters and acid dissociation constants in nylon-solvent systems, it is precisely control crystallization to assemble interlaced 1D nanofiber skeletons, yielding nylon aerogels that integrate a high specific surface area (226 m g), exceptional compressive modulus (12.

View Article and Find Full Text PDF