Publications by authors named "Joseph G Akar"

Introduction: Identifying patients who will develop a need for right ventricular (RV) pacing after defibrillator (ICD) placement would help inform appropriate device selection, specifically to identify patients who might be more suitable for dual chamber or biventricular transvenous defibrillators versus single-chamber or subcutaneous devices which do not provide pacing. We sought to determine predictors of RV pacing in patients who did not have a pacing indication at the time of initial ICD implant.

Methods: This observational study assessed single-chamber ICD recipients implanted from 2006 to 2016 from Boston Scientific's ALTITUDE database and linked to the NCDR® ICD Registry.

View Article and Find Full Text PDF

Aims: The concept of "atrial cardiomyopathy" (AtCM) had been percolating through the literature since its first mention in 1972. Since then, publications using the term were sporadic until the decision was made to convene an expert working group with representation from four multinational arrhythmia organizations to prepare a consensus document on atrial cardiomyopathy in 2016 (EHRA/HRS/APHRS/SOLAECE expert consensus on atrial cardiomyopathies: definition, characterization, and clinical implication). Subsequently, publications on AtCM have increased progressively.

View Article and Find Full Text PDF

Introduction: Screening for atrial fibrillation (AF) in the general population may help identify individuals at risk, enabling further assessment of risk factors and institution of appropriate treatment. Algorithms deployed on wearable technologies such as smartwatches and fitness bands may be trained to screen for such arrhythmias. However, their performance needs to be assessed for safety and accuracy prior to wide-scale implementation.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF)-the most common sustained cardiac arrhythmia-increases thromboembolic stroke risk 5-fold. Although atrial hypocontractility contributes to stroke risk in AF, the molecular mechanisms reducing myofilament contractile function remain unknown. We tested the hypothesis that increased expression of PPP1R12C (protein phosphatase 1 regulatory subunit 12C)-the PP1 (protein phosphatase 1) regulatory subunit targeting MLC2a (atrial myosin light chain 2)-causes hypophosphorylation of MLC2a and results in atrial hypocontractility.

View Article and Find Full Text PDF
Article Synopsis
  • Researchers wanted to see if adding extra treatments during heart procedures (besides the usual one) caused more problems for patients with heart issues called atrial fibrillation (AF).
  • They looked at a lot of patients (over 50,000) and compared those who just had the usual treatment to those who had extra treatments.
  • They found that while extra treatments didn’t cause more problems for some patients, there was a higher chance of complications for certain patients with more serious heart issues.
View Article and Find Full Text PDF

Background: Atrial fibrillation (AF), the most common sustained cardiac arrhythmia, increases thromboembolic stroke risk five-fold. Although atrial hypocontractility contributes to stroke risk in AF, the molecular mechanisms reducing myofilament contractile function remain unknown. We tested the hypothesis that increased expression of PPP1R12C, the PP1 regulatory subunit targeting atrial myosin light chain 2 (MLC2a), causes hypophosphorylation of MLC2a and results in atrial hypocontractility.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the underutilization of cardiac resynchronization therapy-defibrillator (CRT-D) despite existing guidelines, revealing significant differences in its application across hospitals.
  • It analyzed Medicare claims data linked with the National Cardiovascular Data Registry from 2010 to 2015, finding that 74% of variation in CRT-D usage was due to the specific hospital rather than patient factors.
  • The findings indicate that varying rates of CRT-D use can lead to clinically meaningful differences in hospital-level outcomes, making CRT-D utilization a potential target for improving healthcare quality.
View Article and Find Full Text PDF

Background: Although implantable cardioverter-defibrillator (ICD) therapies are associated with increased morbidity and mortality, the prediction of malignant ventricular arrhythmias has remained elusive.

Objectives: The purpose of this study was to evaluate whether daily remote-monitoring data may predict appropriate ICD therapies for ventricular tachycardia or ventricular fibrillation.

Methods: This was a post hoc analysis of IMPACT (Randomized trial of atrial arrhythmia monitoring to guide anticoagulation in patients with implanted defibrillator and cardiac resynchronization devices), a multicenter, randomized, controlled trial of 2,718 patients evaluating atrial tachyarrhythmias and anticoagulation for patients with heart failure and ICD or cardiac resynchronization therapy with defibrillator devices.

View Article and Find Full Text PDF
Article Synopsis
  • Atrial cardiomyopathy significantly impacts heart function and patient outcomes, with the left atrial (LA) appendage playing a critical yet not fully understood role.
  • A study involving 25 patients assessed how percutaneous LA appendage occlusion (LAAO) affects LA stiffness through innovative pressure-volume analysis using advanced imaging techniques.
  • Results showed that LA stiffness increased after LAAO, and the size of the LA appendage before the procedure was strongly associated with the extent of stiffness increase, highlighting the appendage's role in LA mechanics and potential implications for atrial remodeling in at-risk patients.
View Article and Find Full Text PDF

Metabolic stress is an important cause of pathological atrial remodeling and atrial fibrillation. AMPK is a ubiquitous master metabolic regulator, yet its biological function in the atria is poorly understood in both health and disease. We investigated the impact of atrium-selective cardiac AMPK deletion on electrophysiological and structural remodeling in mice.

View Article and Find Full Text PDF

Background: The subcutaneous (S-) implantable cardioverter-defibrillator (ICD) is an alternative to the transvenous (TV-) ICD that is increasingly implanted in younger patients; data on the safety and effectiveness of the S-ICD in older patients are lacking.

Objectives: The purpose of this study was to compare outcomes among older patients who received an S- or TV-ICD.

Methods: The authors compared S-ICD and single-chamber TV-ICD implants in Fee-For-Service Medicare beneficiaries using the National Cardiovascular Data Registry ICD Registry.

View Article and Find Full Text PDF

Background: Personal digital devices may offer insights into patient recovery and an approach for remote monitoring after procedures.

Objective: To examine associations between activity measured using personal digital devices, patient-reported outcome measures (PROMs), and clinical events among patients after catheter ablation for atrial fibrillation (AF) or bariatric surgery.

Methods: We aggregated personal digital device, PROM, and electronic health record data in a study conducted at 2 health systems.

View Article and Find Full Text PDF

Aims: Atrial fibrillation (AF) is associated with atrial enlargement, mitral annulus (MA) and tricuspid annulus (TA) dilation, and atrial functional regurgitation (AFR). However, less is known about the impact of AF on both atrioventricular valves in those with normal and abnormal ventricular function. We aimed to compare the remodelling of the TA and MA in patients with non-valvular AF without significant AFR.

View Article and Find Full Text PDF

Introduction: Personal digital devices that provide health information, such as the Apple Watch, have developed an increasing array of cardiopulmonary tracking features which have received regulatory clearance and are directly marketed to consumers. Despite their widespread and increasing use, data about the impact of personal digital device use on patient-reported outcomes and healthcare utilisation are sparse. Among a population of patients with atrial fibrillation and/or atrial flutter undergoing cardioversion, our primary aim is to determine the impact of the heart rate measurement, irregular rhythm notification, and ECG features of the Apple Watch on quality of life and healthcare utilisation.

View Article and Find Full Text PDF

Background: Left ventricular (LV) remodeling following a myocardial infarction (MI) is associated with new-onset atrial fibrillation (AF). LV remodeling post-MI is characterized by regional changes in matrix metalloproteinases (MMPs) and tissue inhibitors of metalloproteinases (TIMPs), causing extracellular matrix (ECM) remodeling.

Objective: The purpose of this study was to test the hypothesis that a shift in regional atrial MMP activity, MMP/TIMP expression, and ECM remodeling occurs post-MI, which cause increased vulnerability to AF.

View Article and Find Full Text PDF

Percutaneous left atrial appendage (LAA) occlusion is increasingly performed in patients with atrial fibrillation and long-term contraindications for anticoagulation. Our aim was to evaluate the effects of LAA occlusion with the Watchman device on the geometry of the LAA orifice and assess its impact on the adjacent left upper pulmonary vein (LUPV) hemodynamics. We included 50 patients who underwent percutaneous LAA occlusion with the Watchman device and had acceptable three-dimensional transesophageal echocardiography images of LAA pre- and post-device placement.

View Article and Find Full Text PDF

Objectives: To determine the feasibility of using real-world data to assess the safety and effectiveness of two cardiac ablation catheters for the treatment of persistent atrial fibrillation and ischaemic ventricular tachycardia.

Design: Retrospective cohort.

Setting: Three health systems in the USA.

View Article and Find Full Text PDF

Background: Electrophysiological (EP) properties have been studied mainly in the monocrotaline model of pulmonary arterial hypertension (PAH). Findings are confounded by major extrapulmonary toxicities, which preclude the ability to draw definitive conclusions regarding the role of PAH per se in EP remodeling.

Objective: The purpose of this study was to investigate the EP substrate and arrhythmic vulnerability of a new model of PAH that avoids extracardiopulmonary toxicities.

View Article and Find Full Text PDF

The genetic causes of atrial fibrillation (AF) with slow conduction are unknown. Eight kindreds with familial AF and slow conduction, including a family affected by early-onset AF, heart block, and incompletely penetrant nonischemic dilated cardiomyopathy (DCM) underwent whole exome sequencing. A known pathogenic mutation in the desmin (DES) gene resulting in p.

View Article and Find Full Text PDF

Objectives: Contact force-sensing catheters allow real-time catheter-tissue contact force monitoring during atrial fibrillation. These catheters were rapidly adopted into clinical practice following market introduction in 2014, but concerns have been raised regarding collateral damage such as esophageal injury. We sought to examine whether the introduction of force-sensing catheters was associated with a change in short-term and intermediate-term acute care use, complications and mortality following atrial fibrillation ablation.

View Article and Find Full Text PDF

Objectives: This study identified factors associated with risk for cardiac perforation in the setting of atrial fibrillation (AF) ablation in contemporary clinical practice.

Background: Cardiac perforation is an uncommon but potentially fatal complication of AF ablation. An improved understanding of factors associated with cardiac perforation could facilitate improvements in procedural safety.

View Article and Find Full Text PDF

Objectives: This study sought to define electrographic characteristics of the fossa ovalis (FO) and use these findings in developing a 3-dimensional (3D) transseptal puncture (TSP) technique that does not rely on fluoroscopy or echocardiography.

Background: Traditional TSP method based on fluoroscopy or echocardiography is basically a 2-dimensional (2D) technique. A valid 3D method of TSP has not been sufficiently clarified.

View Article and Find Full Text PDF