Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Objectives: To determine the feasibility of using real-world data to assess the safety and effectiveness of two cardiac ablation catheters for the treatment of persistent atrial fibrillation and ischaemic ventricular tachycardia.
Design: Retrospective cohort.
Setting: Three health systems in the USA.
Participants: Patients receiving ablation with the two ablation catheters of interest at any of the three health systems.
Main Outcome Measures: Feasibility of identifying the medical devices and participant populations of interest as well as the duration of follow-up and positive predictive values (PPVs) for serious safety (ischaemic stroke, acute heart failure and cardiac tamponade) and effectiveness (arrhythmia-related hospitalisation) clinical outcomes of interest compared with manual chart validation by clinicians.
Results: Overall, the catheter of interest for treatment of persistent atrial fibrillation was used for 4280 ablations and the catheter of interest for ischaemic ventricular tachycardia was used 1516 times across the data available within the three health systems. The duration of patient follow-up in the three health systems ranged from 91% to 97% at ≥7 days, 89% to 96% at ≥30 days, 77% to 90% at ≥6 months and 66% to 84% at ≥1 year. PPVs were 63.4% for ischaemic stroke, 96.4% for acute heart failure, 100% at one health system for cardiac tamponade and 55.7% for arrhythmia-related hospitalisation.
Conclusions: It is feasible to use real-world health system data to evaluate the safety and effectiveness of cardiac ablation catheters, though evaluations must consider the implications of variation in follow-up and endpoint ascertainment among health systems.