Article Abstract

In this study, a comprehensive approach for the experimental assessment of the absorbed power density (APD) is developed. The method includes several novel components: (i) a specialized probe, (ii) a composite phantom, (iii) a reconstruction technique, (iv) a calibration method, and (v) a validation process. The described solution has been developed for the frequency range from 24 to 30 GHz, but can be extended to all frequency bands between 10 and 45 GHz. A novel composite phantom emulates the reflection and transmission coefficients of human skin for propagating and evanescent modes, while its increased penetration depth, in comparison to dermis tissue, enables the measurement of the induced electromagnetic fields (EMFs) with a new miniaturized dosimetric broadband probe. The implementation has a wide dynamic range and sufficient spatial resolution to use it for type approval of mobile devices. Its probe is calibrated with low uncertainty in a novel, traceable setup. A set of reference antennas with known numerical target values for the APD has been compiled to validate the measurement system. The validation demonstrates that the deviation is within the expanded uncertainty of 1.6 dB for pAPD and  1.5 dB for psAPD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12351234PMC
http://dx.doi.org/10.1002/bem.70018DOI Listing

Publication Analysis

Top Keywords

assessment absorbed
8
absorbed power
8
power density
8
composite phantom
8
traceable assessment
4
density body
4
body mounted
4
mounted devices
4
devices frequencies
4
frequencies ghz
4

Similar Publications

Hepatotoxicity induced by polylactic acid microplastics: The mediating role of gut microbiota and uric acid metabolism.

J Adv Res

September 2025

National Medical Products Administration (NMPA) Key Laboratory for Safety Evaluation of Cosmetics, Guangdong Provincial Key Laboratory of Tropical Disease Research, Department of Toxicology, School of Public Health, Southern Medical University, Guangzhou, China. Electronic address: huangzhenlie85825

Introduction: The increasing use of biodegradable plastics has led to the inevitable human consumption of biodegradable microplastics (MPs). These MPs can be degraded and absorbed into various organs and tissues via the gastrointestinal tract, with the liver being the primary target for digestion and absorption.

Objectives: This study aimed to investigate the toxic effects and mechanisms of biodegradable MPs on the liver following gastrointestinal degradation.

View Article and Find Full Text PDF

Photodegradation of PET plastics produces persistent compounds that accumulate in sediments.

Mar Pollut Bull

September 2025

Department of Chemistry, Kyungpook National University, Daegu 41566, Republic of Korea; Mass Spectrometry Based Converging Research Institute, Daegu 41566, Republic of Korea. Electronic address:

Polyethylene terephthalate (PET) is one of the most widely used plastics, particularly in packaging and textiles. Although PET is widely used in consumer products, only 10-28 % is recycled. Most PET waste is not properly managed.

View Article and Find Full Text PDF

Silicon-based ligands are of interest in increasingly used Prostate-specific membrane antigen (PSMA) tracers for prostate cancer (PCa) staging due to their simple and scalable production. Here, we present first data on dosimetry and biodistribution of the novel PSMA-specific tracer [¹⁸F]siPSMA-14.Seven PCa patients referred for PSMA-PET/CT imaging were imaged at 60 and 120 min p.

View Article and Find Full Text PDF

Optimal proportions of plasticizers, crosslinkers, and hydrophobicity modifiers are essential for biopolymer film formulations. In this study, Cellulose acetate bioplastic films were prepared with varying concentrations of polyethylene glycol (PEG), malic acid (MA), and hexadecanoic acid (HAD). The resulting films were characterized for thickness (TH), water absorbency (WA), transparency (TP), and equilibrium moisture content (MC).

View Article and Find Full Text PDF

To assess the efficacy of a mixed-dimensional van der Waals (vdW) heterostructure in modulating the optoelectronic responses of nanodevices, the charge transport properties of the transition-metal dichalcogenide (TMD)-based heterostructure comprising zero-dimensional (0D) WS quantum dots (QDs) and two-dimensional (2D) MoS flakes are critically analyzed. Herein, a facile strategy was materialized in developing an atomically thin phototransistor assembled from mechanically exfoliated MoS and WS QDs synthesized using a one-pot hydrothermal route. The amalgamated photodetectors exhibited a high responsivity of ∼8000 A/W at an incident power of 0.

View Article and Find Full Text PDF