Feasibility and accuracy of the fully automated three-dimensional echocardiography right ventricular quantification software in children: validation against cardiac magnetic resonance.

Pediatr Radiol

Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Clinical Research Center for Medical Imaging in Hubei Province, Hubei Province Key Laboratory of Molecular Imaging, 1277 Jiefang Avenue, Wuhan, 430022, China.

Published: July 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Previous studies have confirmed that fully automated three-dimensional echocardiography (3DE) right ventricular (RV) quantification software can accurately assess adult RV function. However, data on its accuracy in children are scarce.

Objective: This study aimed to test the accuracy of the software in children using cardiac magnetic resonance (MR) as the gold standard.

Materials And Methods: This study prospectively enrolled 82 children who underwent both echocardiography and cardiac MR within 24 h. The RV end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were obtained using the novel 3DE-RV quantification software and compared with cardiac MR values across different groups.

Results: The novel 3DE-RV quantification software was feasible in all 82 children (100%). Fully automated analysis was achieved in 35% patients with an analysis time of 8 ± 2 s and 100% reproducibility. Manual editing was necessary in the remaining 65% patients. The 3DE-derived RV volumes and EF correlated well with cardiac MR measurements (RVEDV, r=0.93; RVESV, r=0.90; RVEF, r=0.82; all P <0.001). Although the automated approach slightly underestimated RV volumes and overestimated RVEF compared with cardiac MR in the entire cohort, the bias was smaller in children with RVEF ≥ 45%, normal RV size, and good 3DE image quality.

Conclusion: Fully automated 3DE-RV quantification software provided accurate and completely reproducible results in 35% children without any adjustment. The RV volumes and EF measured using the automated 3DE method correlated well with those from cardiac MR, especially in children with RVEF ≥ 45%, normal RV size, and good 3DE image quality. Therefore, the novel automated 3DE method may achieve rapid and accurate assessment of RV function in children with normal heart anatomy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00247-025-06330-2DOI Listing

Publication Analysis

Top Keywords

quantification software
16
fully automated
12
automated three-dimensional
8
three-dimensional echocardiography
8
ventricular quantification
8
software children
8
cardiac magnetic
8
magnetic resonance
8
novel 3de-rv
8
3de-rv quantification
8

Similar Publications

The helical morphology of Type B aortic dissections (TBAD) represents a potentially important geometric biomarker that may influence dissection progression. While three-dimensional surface-based quantification methods provide accurate TBAD helicity assessment, their clinical adoption remains limited by significant processing time. We developed and validated a clinically practical centerline-based helicity quantification method using routine imaging software (TeraRecon) against an extensively validated surface-based method (SimVascular).

View Article and Find Full Text PDF

Accurate tumor mutation burden (TMB) quantification is critical for immunotherapy stratification, yet remains challenging due to variability across sequencing platforms, tumor heterogeneity, and variant calling pipelines. Here, we introduce TMBquant, an explainable AI-powered caller designed to optimize TMB estimation through dynamic feature selection, ensemble learning, and automated strategy adaptation. Built upon the H2O AutoML framework, TMBquant integrates variant features, minimizes classification errors, and enhances both accuracy and stability across diverse datasets.

View Article and Find Full Text PDF

Objective: This study evaluates age- and sex-related differences in brain volume, including normalized gray matter (nGM), normalized white matter (nWM), cerebrospinal fluid (CSF) volume, and total intracranial volume (TIV) in cognitively normal adults using automatic volume segmentation on 3.0 Tesla MRI.

Methods: A prospective cross-sectional study conducted from October 2021 to September 2022 included 110 cognitively normal participants.

View Article and Find Full Text PDF

A correlation-based tool for quantifying membrane periodic skeleton associated periodicity.

Front Neuroinform

August 2025

Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.

Introduction: The advent of super-resolution microscopy revealed the membrane-associated periodic skeleton (MPS), a specialized neuronal cytoskeletal structure composed of actin rings spaced 190 nm apart by two spectrin dimers. While numerous ion channels, cell adhesion molecules, and signaling proteins have been shown to associate with the MPS, tools for accurate and unbiased quantification of their periodic localization remain scarce.

Methods: We developed Napari-WaveBreaker (https://github.

View Article and Find Full Text PDF

A sensitive smartphone-based method for measuring phosphate in biological samples and ATPase activities.

Talanta

August 2025

Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Departamento de Química Biológica, Junín 956, Buenos Aires, Argentina; Laboratorio de Biofísica Molecular, Instituto de Química y Fisicoquímica Biológicas, UBA - CONICET, Junín 956, Buenos Aires, Argentina. Electronic address:

The quantification of orthophosphate is essential for applications like water quality assessment, soil fertility analysis, metabolic monitoring and enzyme activity evaluation. Chemical quantification methods include the reaction between orthophosphate and molybdate under acidic conditions to form 12-molybdophosphoric acid units, which auto-assembles forming nanometer size particles. The adsorption of malachite green to these nanoparticles allows their spectrophotometric detection constituting one of the most widely used methods to quantify phosphate.

View Article and Find Full Text PDF