98%
921
2 minutes
20
Purpose: Laparoscopic total extraperitoneal (TEP) inguinal hernia repair is a well-established technique. In Taiwan, the National Health Insurance (NHI) covers the fees of the procedure and conventional mesh (polypropylene mesh), whereas the anatomical polyester mesh (Parietex™) requires additional self-pay. This study aimed to compare the outcomes of the conventional mesh with fixation versus the polyester mesh (without fixation) in laparoscopic TEP repair.
Methods: We retrospectively reviewed the medical records of male patients who underwent laparoscopic TEP repair between 2017 and 2021. Patients could choose between the conventional mesh with fixation (conventional mesh group) or self-paid Parietex™ mesh without fixation (anatomical polyester mesh group). The outcomes included operation (OP) time, prolonged length of stay (LOS), and postoperative complications.
Results: A total of 74 patients with 123 hernias were included, of which 36 patients (67 hernias) underwent the anatomical mesh without fixation, while 38 patients (56 hernias) underwent the conventional mesh with fixation. The mean OP time was 102.6 ± 45.6 and 88.5 ± 42.0 min in the conventional and the anatomical polyester mesh group. After adjusting for body mass index, diabetes mellitus, cardiovascular disease, and hernia type, no significant differences were observed between the two groups in OP time (p = 0.152) and the risk of acute pain (p = 0.337), chronic pain (p = 0.816), seroma (p = 0.941), hydrocele (p = 0.423), or hematoma (p = 0.347).
Conclusions: The conventional mesh demonstrates non-inferior outcomes compared to the anatomical polyester mesh. Given that the anatomical polyester mesh is not reimbursed by Taiwan's National Health Insurance (NHI), the use of the conventional mesh with fixation in TEP inguinal hernia repair may be a more cost-effective option in Taiwan.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10029-024-03231-5 | DOI Listing |
Front Med (Lausanne)
August 2025
Department of General Surgery, Affiliated Hospital of Hebei University, Baoding, Hebei, China.
De Garengeot hernia, characterized by appendiceal incarceration within a femoral canal hernia sac, is a rare condition with high risks of strangulation. Traditional open repair remains standard, but laparoscopic approaches offer minimally invasive alternatives. However, limited evidence exists on combining laparoscopic transabdominal preperitoneal (TAPP) with biologic mesh for this condition.
View Article and Find Full Text PDFZhongguo Gu Shang
August 2025
Department of Spinal Surgery, Ningbo No.6 Hospital, Ningbo 315040, Zhejiang, China.
Objective: To establish a two-segment vertebrectomy model using the finite element method, and to measure and compare the biomechanical properties of the lower cervical anterior transpedicular root screw (ATPRS) plate system, lower cervical anterior pedicle screw (ATPS) plate system, and lower cervical anterior cervical locked-plate (ACLP) system on this model.
Methods: CT data of the cervical spine (C-T) from a 34-year-old healthy adult male volunteer were collected. A nonlinear complete model of the lower cervical spine (C-C) was established using Mimics 10.
Plast Surg (Oakv)
August 2025
Division of Plastic Surgery, Department of Surgery, University of Alberta, Edmonton, AB, Canada.
Surgical repair of orbital fractures comes with risks. One rare risk is interference with the actions of the superior oblique tendon-muscle complex causing an acquired Brown syndrome. We present the case of a 45-year-old man who developed acquired Brown syndrome after undergoing repair of a large orbital floor and medial orbital wall fracture using a titanium mesh implant.
View Article and Find Full Text PDFActa Biomater
August 2025
Shanghai Frontiers Science Center of Advanced Textiles, College of Textiles, Donghua University, Shanghai 201620, China; Key Laboratory of Textile Science &Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai 201620, China; Key Laboratory of Textile Industry for Biome
Microneedle patches can penetrate the myocardium to facilitate integration with cardiac tissue, offering a promising approach for myocardial infarction (MI) repair. However, their clinical translation has been hindered by insufficient fixation stability during cardiac contractions and mismatch with myocardial anisotropy. To address these challenges, a bioinspired three-dimensional cardiac patch integrating barbed microneedles and an anisotropic lightweight mesh was designed.
View Article and Find Full Text PDFSurg Innov
August 2025
Department of Surgery, Center for Perioperative Optimization, Copenhagen University Hospital Herlev and Gentofte, Herlev, Denmark.
BackgroundThere is currently insufficient evidence to determine whether lightweight or heavyweight mesh is the better choice for ventral hernias. Recurrence and postoperative pain are associated with biomechanical responses such as inflammation, foreign body reaction, cell ingrowth, and tensile strength, which can be examined in animal studies. This study aimed to compare the biomechanical differences between light- and heavyweight meshes in animal models.
View Article and Find Full Text PDF