98%
921
2 minutes
20
Chalcogen-containing carbonyls, specifically thioxanthone (TX), hold great potential in organic light-emitting diodes (OLEDs). While the development of narrowband OLEDs with chalcogen-containing carbonyls remains challenging due to difficulties in achieving both high device efficiency and narrow emission spectra. Herein, via a strategic incorporation of the TX moiety, two orange-red narrowband emitters, 2TXBN and BNTXBN, are designed and synthesized for the first time. Both 2TXBN and BNTXBN exhibit bright orange-red emissions with peaks at 582 and 585 nm, respectively, along with narrow full widths at half maxima of 30 and 32 nm. Notably, 2TXBN demonstrates delocalization of the nonbonding orbital within the TX segment, which raises the first triplet energy level and reduces the singlet-triplet energy gap. This electronic structural adjustment effectively shortens the delayed fluorescence lifetime, leading to enhanced device performance. Accordingly, OLED employing 2TXBN as the emitter achieves remarkable performance, with a maximum external quantum efficiency of 31.0 %, a current efficiency of 69.0 cd A, and a power efficiency of 76.0 lm W, highlighting the efficacy of the nonbonding orbital delocalization strategy in achieving bathochromic-shifted narrowband OLED materials.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/anie.202423602 | DOI Listing |
Dalton Trans
September 2025
Departamento de Fisica Aplicada-ICMUV, MALTA Consolider Team, Universitat de Valencia, Av. Dr. Moliner 50, 46100 Burjassot (Valencia), Spain.
The impact of external pressure on the characteristics of SrTeO has been thoroughly examined using density-functional theory calculations up to 100 GPa. It has been predicted that SrTeO undergoes three phase transitions in the pressure range covered by this study. A first transition occurs at 2.
View Article and Find Full Text PDFWater Res
August 2025
State Key Laboratory of Environmental Aquatic Chemistry, Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
Phosphorus is recognized as a major pollutant in municipal and domestic wastewater, but the effective removal of organic phosphorus (OP) using conventional wastewater treatment technologies is difficult. Herein, a novel visible light-enhanced Ti electrocoagulation (EC) technology was proposed for the removal of OP using 2-amino-ethyl phosphonic acid (AEP) as a model compound to elucidate the removal efficiency and mechanisms. The results showed that the irradiation under visible light (670 Lux) effectively enhanced the removal of AEP by Ti EC.
View Article and Find Full Text PDFInorg Chem
September 2025
Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina 29208, United States.
A series of six quinary rare-earth sulfides CeEuNaSiS, CeEuKSiS, CeEuRbSiS, CeEuCsSiS, CeEuAgSiS, and CeEuCuSiS were obtained in an alkali iodide flux using the boron-chalcogen mixture (BCM) method. Single crystal X-ray diffraction was used to determine the structures of the high quality single crystals that were grown; their elemental compositions were confirmed by energy-dispersive spectroscopy (EDS). The compounds crystallize in the hexagonal crystal system in the noncentrosymmetric space group 6.
View Article and Find Full Text PDFACS Appl Mater Interfaces
September 2025
L. V. Pisarzhevsky Institute of Physical Chemistry of NASU SE "RADMA", 31, pr. Nauky ave, Kyiv 03680, Ukraine.
The effect of electron irradiation ( = 1.8 MeV) on the optical properties of polyethylene glycol 400-multiwalled carbon nanotube (PEG-400/MWCNT) nanocomposite films was studied within an absorbed dose range of 0 to 0.4 MGy.
View Article and Find Full Text PDFAnal Chim Acta
November 2025
Department of Clinical Laboratory Medicine, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, 200072, PR China.
Background: A DNA barcode is a short DNA fragment used to classify and identify specific organisms, taking advantage of the specificity and diversity inherent in biological molecules. Since Herbert introduced the concept in 2003, DNA barcoding has been increasingly used in precision medicine and related fields, including species identification and environmental monitoring, over the past few decades. Although numerous molecular diagnostic techniques have emerged, many face notable obstacles such as sensitivity to handling conditions, high expenses, and limitations in accuracy.
View Article and Find Full Text PDF