On-site biosignal amplification using a single high-spin conjugated polymer.

Nat Commun

National Key Laboratory of Advanced Micro and Nano Manufacture Technology, School of Materials Science and Engineering, Peking University, Beijing, China.

Published: January 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

On-site or in-sensor biosignal transduction and amplification can offer several benefits such as improved signal quality, reduced redundant data transmission, and enhanced system integration. Ambipolar organic electrochemical transistors (OECTs) are promising for this purpose due to their high transconductance, low operating voltage, biocompatibility, and suitability for miniaturized amplifier design. However, limitations in material performance and stability have hindered their application in biosignal amplification. Here, we propose using high-spin, hydrophilic conjugated polymers and a computational screening approach to address this challenge. We designed a high-spin polymer, namely P(TII-2FT), which exhibits satisfactory, stable, and balanced ambipolar OECT performance. The figure-of-merits achieved by the P(TII-2FT) devices surpass those of the current leading materials by 5 to 20 times, resulting in remarkable voltage gains while maintaining a compact form factor. Based on this amplifier, we have successfully achieved on-site capture and amplification of various electrophysiological signals with greatly enhanced signal quality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11700166PMC
http://dx.doi.org/10.1038/s41467-024-55369-6DOI Listing

Publication Analysis

Top Keywords

biosignal amplification
8
signal quality
8
on-site biosignal
4
amplification
4
amplification single
4
single high-spin
4
high-spin conjugated
4
conjugated polymer
4
polymer on-site
4
on-site in-sensor
4

Similar Publications

Organic electrochemical transistors (OECTs) are key components in advanced bioelectronics, wearable devices, and neuromorphic biointerfaces. However, to fully unlock their potential and facilitate widespread adoption, the development of high-performance OECTs and their seamless integration into circuits is essential, yet still limited. In this work, the monolithic integration of OECTs and OECT-based amplifiers, fabricated entirely on flexible substrates using high-resolution micro-dispensing, is reported.

View Article and Find Full Text PDF

This study reproduced changes according to the central-brachial-radial blood pressure wave propagation using a cardiovascular hardware simulator. Blood pressure is a key indicator of cardiovascular health, and its importance has recently emerged, and research into the correlation between the two is in progress. This requires a large amount of clinical data, but the amount and distribution are limited.

View Article and Find Full Text PDF

A self-powered biosensor with cascade amplification capability facilitates ultra-sensitive detection of microRNA biomarkers.

Biosens Bioelectron

May 2025

Department of Urology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, China; Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Xi'an Jiaotong University, Xi'an, 710061, China. Electronic address:

Sensitive microRNA (miRNA) detection is crucial for cancer diagnosis. Self-powered biosensors that are used for miRNA detection show the advantages of no external power supply, mild reaction conditions, portability, etc., but still face the challenges of low efficiency of solid electrode adsorption enzyme and insufficient enzyme active site.

View Article and Find Full Text PDF

On-site biosignal amplification using a single high-spin conjugated polymer.

Nat Commun

January 2025

National Key Laboratory of Advanced Micro and Nano Manufacture Technology, School of Materials Science and Engineering, Peking University, Beijing, China.

On-site or in-sensor biosignal transduction and amplification can offer several benefits such as improved signal quality, reduced redundant data transmission, and enhanced system integration. Ambipolar organic electrochemical transistors (OECTs) are promising for this purpose due to their high transconductance, low operating voltage, biocompatibility, and suitability for miniaturized amplifier design. However, limitations in material performance and stability have hindered their application in biosignal amplification.

View Article and Find Full Text PDF

Electromyography (EMG) stands out as an accessible and inexpensive method for identifying muscle contractions on the surface and within deeper muscle tissues. Using specialized electronic circuits for amplification and filtering can help develop simple but effective systems for detecting and analyzing these signals. However, EMG devices developed by research teams frequently lack rigorous methodologies for validating the quality of the signals they record compared to those obtained by commercial systems that have undergone extensive testing and regulatory approval for market release.

View Article and Find Full Text PDF