Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Electromyography (EMG) stands out as an accessible and inexpensive method for identifying muscle contractions on the surface and within deeper muscle tissues. Using specialized electronic circuits for amplification and filtering can help develop simple but effective systems for detecting and analyzing these signals. However, EMG devices developed by research teams frequently lack rigorous methodologies for validating the quality of the signals they record compared to those obtained by commercial systems that have undergone extensive testing and regulatory approval for market release. This underscores the critical need for standardized validation techniques to reliably assess the performance of experimental devices relative to established commercial equipment. Hence, this study introduces a methodology for the development and statistical validation of a laboratory EMG circuit compared with a professional device available on the market. The experiment simultaneously recorded the muscle electrical activity of 18 volunteers using two biosignal acquisition devices-a prototype EMG and a commercial system-both applied in parallel at the same recording site. Volunteers performed a series of finger and wrist extension movements to elicit myoelectric activity in these forearm muscles. To achieve this, it was necessary to develop not only the EMG signal conditioning board, but also two additional interface boards: one for enabling parallel recording on both devices and another for synchronizing the devices with the task programmatically controlled in Python that the volunteers were required to perform. The EMG signals generated during these tasks were recorded simultaneously by both devices. Subsequently, 22 feature indices commonly used for classifying muscular activity patterns were calculated from two-second temporal windows of the recordings to extract detailed temporal and spatial characteristics. Finally, the Mean Absolute Percentage Error (MAPE) was computed to compare the indices from the prototype with those from the commercial device, using this method as a validation system to assess the quality of the signals recorded by the prototype relative to the commercial equipment. A concordance of 87.6% was observed between the feature indices calculated from the recordings of both devices, suggesting high effectiveness and reliability of the EMG signals recorded by the prototype compared to the commercial device. These results validate the efficacy of our EMG prototype device and provide a solid foundation for the future evaluation of similar devices, ensuring their reliability, accuracy, and suitability for research or clinical applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11548475PMC
http://dx.doi.org/10.3390/s24216787DOI Listing

Publication Analysis

Top Keywords

commercial device
12
statistical validation
8
emg
8
quality signals
8
compared commercial
8
commercial equipment
8
parallel recording
8
emg signals
8
feature indices
8
signals recorded
8

Similar Publications

Cardiovascular diseases (CVDs) remain a leading cause of death, particularly in developing countries, where their incidence continues to rise. Traditional CVD diagnostic methods are often time-consuming and inconvenient, necessitating more efficient alternatives. Rapid and accurate measurement of cardiac biomarkers released into body fluids is critical for early detection, timely intervention, and improved patient outcomes.

View Article and Find Full Text PDF

Wafer-scale integration of monolayer MoS residue-free support layer etching and angular strain suppression.

Nanoscale

September 2025

Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore 138634, Republic of Singapore.

A crack-free and residue-free transfer technique for large-area, atomically-thin 2D transition metal dichalcogenides (TMDCs) such as MoS and WS is critical for their integration into next-generation electronic devices, either as channel materials replacing silicon or as back-end-of-line (BEOL) components in 3D-integrated nano-systems on CMOS platforms. However, cracks are frequently observed during the debonding of TMDCs from their growth substrates, and polymer or metal residues are often left behind after the removal of adhesive support layers wet etching. These issues stem from excessive angular strain accumulated during debonding and the incomplete removal of support layers due to their low solubility.

View Article and Find Full Text PDF

Tuberous breast deformity in a transgender woman: a case report.

J Surg Case Rep

September 2025

Division of Plastic and Reconstructive Surgery, University of California, Los Angeles, 200 Medical Plaza, Suite 460, Los Angeles, CA 90095, United States.

Tuberous breast deformity was first documented by Rees and Aston in 1976. The deformity is well documented in cisgender women, with rare cases in cisgender men often associated with gynecomastia, and almost no reports in transgender women. Herein, we present a case of a 32-year-old transgender woman who developed bilateral tuberous breast deformity after 10 years of hormone replacement therapy.

View Article and Find Full Text PDF

Introduction: This study examined the impacts of different negative pressure cupping therapies (PCT) on pain relief, functional recovery, and inflammatory regulation in delayed onset muscle soreness (DOMS) after high-intensity exercise, with the aim of clarifying the dose-effect relationship.

Methods: In this study, 55 healthy male participants aged 18-25 were selected and divided into 5 groups: the control group (CTR;  = 11) and NPCT groups at different levels (-25 kPa, -35 kPa, -45 kPa, and -55 kPa;  = 11 in each group). A high-intensity protocol, which included 6 sets of lunges, squats, and squat jumps, was adopted to induce DOMS in the quadriceps femoris.

View Article and Find Full Text PDF

Incision capsular bag herniation during subluxated lens surgery: mechanisms, management, and prevention.

Front Med (Lausanne)

August 2025

Eye Center, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.

Purpose: To investigate the mechanism, intraoperative characteristics, management, and prevention of incision capsular bag herniation (ICBH), a previously unreported complication during cataract surgery in eyes with lens subluxation.

Methods: A retrospective observational case series was conducted on five male patients who developed ICBH during phacoemulsification with intraocular lens (IOL) implantation between January 2019 and December 2024. Among 867 subluxated-lens surgeries performed during this period, the estimated incidence of ICBH was 0.

View Article and Find Full Text PDF