Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Importance: Long-term variability of blood pressure may be associated with visual field (VF) progression in patients with glaucoma.

Objectives: To investigate the association between blood pressure parameters and VF progression over time in patients with glaucoma.

Design, Setting, And Participants: This retrospective cohort study of longitudinal data included patients with suspected or confirmed glaucoma who were selected from the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. Patients underwent blood pressure and VF testing from November 2000 to December 2022, and data were analyzed in October 2023.

Exposure: Suspected or confirmed glaucoma.

Main Outcomes And Measures: Mean and SD values of blood pressure variables were calculated for systolic and diastolic arterial pressures. These parameters were incorporated into multivariable mixed-effect models to investigate the association between blood pressure parameters and mean intraocular pressure with rates of VF mean deviation loss. Interaction terms between blood pressure parameters and mean intraocular pressure were also included in the models.

Results: A total of 1674 eyes from 985 patients were assessed (mean [SD] age, 61.2 [0.4] years; 563 female [57.2%]). The mean rate of VF mean deviation change was -0.13 (95% CI, -0.16 to -0.10) dB/y over a mean follow-up of 8.0 (95% CI, 7.7-8.2) years. The interaction terms of higher mean blood pressure and higher SD of blood pressure were associated with faster annual mean deviation changes for both mean arterial pressure (0.02 [95% CI, 0.01-0.04] dB/y per 1-mm Hg higher; P = .001) and diastolic arterial pressure (0.02 [95% CI, 0.01-0.03] dB/y per 1-mm Hg higher; P < .001). The interaction term of higher SD of blood pressure and higher mean intraocular pressure was associated with faster annual mean deviation changes for both mean arterial pressure (0.01 [95% CI, 0.00-0.02] μm per 1-mm Hg higher; P = .003) and diastolic arterial pressure (0.01 [95% CI, 0.00-0.01] μm per 1-mm Hg higher; P = .001).

Conclusions And Relevance: In this cohort study, higher mean blood pressure and higher SD of blood pressure were associated with faster VF progression. These findings suggest that long-term variability of blood pressure may be a modifier of the association between intraocular pressure and VF progression in glaucoma.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11565290PMC
http://dx.doi.org/10.1001/jamaophthalmol.2024.4868DOI Listing

Publication Analysis

Top Keywords

blood pressure
36
pressure
13
pressure parameters
12
visual field
8
field progression
8
blood
8
pressure associated
8
investigate association
8
association blood
8
suspected confirmed
8

Similar Publications

Optimized FDA Blood Pump: A Case Study in System-Level Customized Ventricular Assist Device Designs.

Ann Biomed Eng

September 2025

Department of Mechanical Engineering, Koc University, Rumeli Feneri Campus, Sarıyer, 34450, Istanbul, Turkey.

Purpose: The design and development of ventricular assist devices have heavily relied on computational tools, particularly computational fluid dynamics (CFD), since the early 2000s. However, traditional CFD-based optimization requires costly trial-and-error approaches involving multiple design cycles. This study aims to propose a more efficient VAD design and optimization framework that overcomes these limitations.

View Article and Find Full Text PDF

Objective: To quantify agreement between oscillometric non-invasive blood pressure (NIBP) and invasive arterial blood pressure (IBP) in infants <500 g during the first postnatal week.

Study Design: Retrospective cohort of infants with a birth weight <500 g admitted to a tertiary NICU (2011-2023). Paired IBP-NIBP readings obtained within 1 min were analyzed.

View Article and Find Full Text PDF

The effects of positive end-expiratory pressure and end-inspiratory pause on dead space and alveolar ventilation in mechanically ventilated dogs.

Vet Anaesth Analg

August 2025

Department of Anesthesiology and Pain Management, Facultad de Ciencias Veterinarias, Universidad de Buenos Aires, Buenos Aires, Argentina.

Objective: To evaluate the effect of 5 cmHO positive end-expiratory pressure (PEEP) and end-inspiratory pause (EIP) on airway dead space (V) and its resultant effects on alveolar tidal volume (V) and physiological dead space-to-tidal volume ratio (V/V) in dorsally recumbent anesthetized dogs.

Study Design: Prospective, controlled clinical study.

Animals: Healthy adult dogs (n = 20, > 20 kg) undergoing elective surgery.

View Article and Find Full Text PDF

Total laryngectomy (TLE) results in the permanent separation of the respiratory and digestive tracts, requiring all airway interventions to occur exclusively via a neck stoma. Although airway obstruction in post-laryngectomy patients is uncommon, it can rapidly become fatal without prompt recognition and understanding of the altered anatomy. Here, we report the case of a patient with a recent TLE for squamous cell carcinoma, who presented to a rural Emergency Department (ED) in acute respiratory distress.

View Article and Find Full Text PDF