Article Abstract

Persistent HPV infection is a major risk factor for the subsequent development of cervical cancer. LAMP is simple and suitable for field detection in the resource-limited settings. In this study, hydroxy naphthol blue (HNB)-based visual LAMP and evagreen-based fluorescent LAMP coupled with a microfluidic chip (LAMP-chip) were established for the field detection of seven subtypes of HPV. The analytical sensitivity was 19-233 copies/reaction. The overall clinical sensitivity was 97.35% for visual LAMP and 98.23% for LAMP-chip. Both LAMP assays exhibited 100% specificity and were completed in less than 50 min. Additionally, both assays did not require complicated nucleic acid extraction and purification steps. A complete quality control monitoring system (including internal control, positive quality control and negative control) in the LAMP assays further ensured the credibility of the results. Our findings demonstrated that the proposed LAMP assays have the potential to be applied in the testing of common HPV DNA in field investigations (visual LAMP) or within communities and primary health centers (LAMP-chip).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11511265PMC
http://dx.doi.org/10.3390/tropicalmed9100240DOI Listing

Publication Analysis

Top Keywords

visual lamp
12
lamp assays
12
lamp
8
field detection
8
quality control
8
field-applicable loop-mediated
4
loop-mediated isothermal
4
isothermal amplification
4
amplification detection
4
detection common
4

Similar Publications

Objectives: To characterise the chorioretinal (CR) manifestations of West Nile virus (WNV) infection using multimodal imaging (MMI).

Methods: Retrospective cohort study including 37 patients with confirmed WNV infection hospitalised at a single centre (July-September 2024). All underwent comprehensive ophthalmological evaluations, including visual acuity, slit-lamp biomicroscopy, fundoscopy, and multimodal imaging: fundus photography, spectral-domain optical coherence tomography (SD-OCT), fundus autofluorescence (FAF), fluorescein angiography, and indocyanine green angiography when clinically indicated.

View Article and Find Full Text PDF

Aloe emodin functionalized dual-channel label with self-adhesion and hydrophobicity for visual monitoring of seafood freshness.

Int J Biol Macromol

September 2025

Key Laboratory of Jianghuai Agricultural Product Fine Processing and Resource Utilization of Ministry of Agriculture and Rural Affairs, College of Food and Nutrition, Anhui Agricultural University, Hefei, 230036, China. Electronic address:

In this study, aloe emodin and β-d-glucose pentaacetate were added into potato starch/polyvinyl alcohol for the construction of colorimetric/fluorescent dual-pass intelligent response labels. Inspired by the lotus leaf structure, retained the advantages of the label itself and solved the hydrophilic problem of the label, and further developed a multi-functional dual-channel smart label with hydrophobicity and self-adhesion. The water contact angle of the prepared T-AEB label was 120.

View Article and Find Full Text PDF

To evaluate B-scan echographic features of endophthalmitis for their correlation with disease characteristics and long-term vision outcomes. Patients diagnosed with endophthalmitis at Massachusetts Eye and Ear between 2011 and 2021 were recruited (N = 209). Data included demographics, infection source, initial therapy, and findings from culture isolates, best corrected visual acuity (BCVA), slit lamp, and B-scan ultrasonography.

View Article and Find Full Text PDF

Traumatic vitreous hemorrhage is most commonly associated with sports injuries or accidental falls. We report an exceptionally rare case of vitreous hemorrhage presumed to result from blunt trauma inflicted by the forepaw of a domestic cat. A 50-year-old man presented with blurred vision and ocular pain in his right eye after being struck by his pet cat.

View Article and Find Full Text PDF

Purpose: This study aims to evaluate rotational stability and patient-reported outcomes associated with Tecnis Eyhance toric II "monofocal plus" intraocular lens (IOL), particularly in light of a modified haptic design.

Methods: A prospective, interventional study was conducted with patients undergoing routine cataract surgery and Tecnis Eyhance toric II IOL implantation. The inclusion criteria were topographic corneal astigmatism of 0.

View Article and Find Full Text PDF