Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: This study aims to evaluate rotational stability and patient-reported outcomes associated with Tecnis Eyhance toric II "monofocal plus" intraocular lens (IOL), particularly in light of a modified haptic design.
Methods: A prospective, interventional study was conducted with patients undergoing routine cataract surgery and Tecnis Eyhance toric II IOL implantation. The inclusion criteria were topographic corneal astigmatism of 0.5-4.0D. Exclusion criteria included previous corneal or ocular surgeries, mesopic pupils >5.5mm, wear of rigid gas-permeable contact lenses, and ophthalmic pathologies that might limit vision outcomes. Toric stability was assessed on day 1, week 1, and month 3 using slit-lamp exams and toriCAM app. Quality of Vision (QoV) and Near Activity Visual Questionnaires (NAVQ) before the surgery and 3 months post-operatively.
Results: The study analyzed 98 eyes from 65 patients. Mean absolute IOL rotation was 1.73±1.64° (range: 0-7°) from day 1 to week 1, with 95% rotating ≤5°. From week 1 to month 3, mean rotation was 1.13±1.53° (range: 0-8°), with 98% rotating ≤5°.
Conclusion: The data from this study suggest that the Tecnis Eyhance toric II IOL exhibits good postoperative rotational stability and positive patient-reported visual outcomes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12402707 | PMC |
http://dx.doi.org/10.2147/OPTH.S515517 | DOI Listing |