Article Abstract

There are limited data on the use of guide catheter extensions (GCE) during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). We examined the frequency and temporal trends of GCE use in a large multicenter CTO-PCI registry and compared the clinical and angiographic characteristics and outcomes of cases with vs without GCE use. A GCE was used in 4106 of 14 521 CTO PCIs (28%) with increasing frequency from 18.8% in 2012 to 29.9% in 2023. The most used GCE size was 6 French (Fr) (45%), followed by 7 Fr (34%), and 8 Fr (21%). CTOs that required GCE use were more likely to have unfavorable lesion characteristics such as moderate-to-severe calcification (59% vs 40%, P less than .0001), moderate-to-severe tortuosity (35% vs 28%, P less than .0001), proximal cap ambiguity (39% vs 33%, P less than .0001), and had higher J-CTO scores (2.78 ± 1.15 vs 2.20 ± 1.27, P less than .0001). Advanced techniques like the retrograde approach (44% vs 24%, P less than .0001) and antegrade dissection and re-entry (28% vs 17%, P less than .0001) were more likely to be used in GCE cases. Technical success (86.6% vs 86.8%, P = .816) was similar between the 2 groups. However, major adverse cardiovascular events (MACE) (3.8% vs 2.4%, P less than .0001) and procedural complications (11.2% vs 8.7%, P less than .0001) were more frequent in the GCE group. In summary, GCE use in CTO PCI significantly increased between 2012 and 2023. Cases that required GCEs were more complex and had similar technical success, but higher incidence of MACE compared with cases that did not require GCEs.

Download full-text PDF

Source
http://dx.doi.org/10.25270/jic/24.00117DOI Listing

Publication Analysis

Top Keywords

gce
9
guide catheter
8
chronic total
8
total occlusion
8
percutaneous coronary
8
coronary intervention
8
0001
8
24% 0001
8
technical success
8
catheter extension
4

Similar Publications

MXene/PANI/SnO electrochemical sensor for the determination of 4-aminophenol.

Mikrochim Acta

September 2025

Key Laboratory of Water Security and Water Environment Protection in Plateau Intersection (NWNU), Ministry of Education, Northwest Normal University, Lanzhou, 730070, China.

An electrochemical sensor based on MXene/PANI/SnO nanomaterials was developed for the detection of 4-aminophenol (4-AP). In situ oxidative growth of PANI on the MXene surface effectively hindered the stacking of the lamellae and increased the specific surface area of the composites. Further complexation of tin dioxide with swelling properties of the structure provided adsorption and catalytic sites for 4-AP.

View Article and Find Full Text PDF

A novel molecularly imprinted polymer (MIP)-based electrochemical sensor has been developed for the selective detection of naringenin (NAR) in various real-world samples, including plant extracts, wine, and herbal supplements. To enhance the active surface area and porosity of the glassy carbon electrode (GCE), a 2D/0D nanocomposite composed of graphene oxide (GO) and cobalt ferrite (CFO) nanoparticles, CFO_GO, was incorporated into the sensor design. 4-aminobenzoic acid (4-ABA) was selected as the functional monomer to prepare the MIPs.

View Article and Find Full Text PDF

Synthesis of Polymer Nanohybrids for Glycerol Sensing, Fluorometric Viscosity Detection, and Metal-Free Electrocatalytic Glycerol Oxidation.

Langmuir

September 2025

Advanced Polymer Laboratory, Department of Polymer Science and Technology, Government College of Engineering and Leather Technology (Post Graduate), Maulana Abul Kalam Azad University of Technology, Salt Lake City, Kolkata 700106, West Bengal, India.

This research provides a constructive approach for developing high-performance polymer nanohybrids toward enhancing optoelectronic properties, fluorogenic viscosity sensing, and metal-free electrocatalytic oxidation of glycerol to value-added organic(s). Herein, reduced graphene oxide (RGO) and mildly oxidized RGO (MRGO) are strategically combined with fluorescent electroactive polymers (FEPs) to develop a promising sustainable metal-free electrocatalytic system suitable for amplifying opto-electrochemical properties, multiplatform sensing capacity, and electrocatalytic efficiency. The optimized polymeric counterpart (FEP2) promotes dual-state emission in the supramolecular network of RGO-/MRGO-incorporated fluorescent electroactive hybrid polymers (RFEHPs/MFEHPs) through physicochemically confined atypical electron-rich -C(═O)NH-/-C(═O)O-/-SOH fluorophores of (hydroxyethyl)methacrylate and 2-acrylamido-2-methylpropane-1-sulfonic acid monomers.

View Article and Find Full Text PDF

BiO/MgInS type-II heterojunction-driven photoelectrochemical sensor for selective detection of tert-butylhydroquinone in edible oils.

Talanta

August 2025

Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, College of Chemistry, Xiangtan University, Xiangtan, 411105, People's Republic of China; Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Xiangtan, 411105, People's Rep

Tert-butylhydroquinone (TBHQ) is a common antioxidant in food oils, and reliable detection methods are needed to ensure food safety. Here, a photoelectrochemical (PEC) sensor based on BiO/MgInS/GCE was developed for the detection of TBHQ. The sensor performance was significantly enhanced through electrostatic assembly of sheet-like BiO onto flower-like MgInS, forming a type-II heterojunction with carefully controlled component ratios, pH, and applied potential.

View Article and Find Full Text PDF

Poly(Amic) Acid Copper Nanocubes as Biocide for .

Langmuir

September 2025

Department of Chemistry and Environmental Sciences, The BioSMART Center, New Jersey Institute of Technology, University Heights, Newark, New Jersey 07102, United States.

Herein, we demonstrate the growth pattern and mechanism of copper nanocubes (CuNCs) on the surface of biodegradable polyamic acid (PAA) film as a function of applied potential. The PAA solution was fabricated via a poly condensation reaction between 4,4'-oxidianiline (ODA) and pyromellitic dianhydride (PMDA) in dimethylacetamide (DMAC) at 25 °C. The resulting viscous PAA solution was drop-cast on a glassy carbon electrode (PAA|GCE) and dried at room temperature.

View Article and Find Full Text PDF