Purpose: Lung cancer is a major cause of cancer-related deaths, emphasizing the importance of early diagnosis. CT-guided percutaneous lung biopsy(CT-PLB) is a valuable method for diagnosing lung lesions, but multiple scans can elevate radiation exposure. This study aims to compare diagnostic efficacy and safety across different CT-PLB protocols.

Methods: 273 consecutive patients who underwent CT-PLB between June 2018 and February 2021 were enrolled, and were divided into standard-dose, conventional low-dose, and experimental low-dose groups. The study mainly evaluated technical success, diagnostic efficacy, radiation dose, complications, and image quality.

Results: 93 patients were assigned to standard-dose group, 85 to conventional low-dose group, and 95 to experimental low-dose group. Technical success rates in these groups were 97.9%, 100%, and 97.9%, respectively. Procedure-related complications rates were similar across the groups(pneumothorax:p=0.71, hemorrhage:p=0.59). Sensitivity, specificity, and overall diagnostic accuracy were comparable among three groups(p=0.59,1.0,0.65), with respective values of 90.5%, 100%, and 93.2% in standard-dose group, 88.1%, 100%, and 90.5% in conventional low-dose group, and 91.9%, 100%, and 93.4% in experimental low-dose group. The effective dose (ED) in the experimental low-dose group was significantly lower compared to both the standard-dose and conventional low-dose CT-PLB groups[ED: 1.49(1.0∼1.97) mSv vs 5.42(3.92∼6.91) mSv vs 3.15(2.52∼4.22) mSv, p<0.001].

Conclusions: This study has developed a standardized six-step procedure for CT-PLB using experimental low-dose settings. It can achieve comparable diagnostic efficacy to conventional low-dose and standard-dose CT-PLB protocols while substantially reducing radiation exposure. These findings indicate that the experimental low-dose protocol could serve as a safe and effective alternative for CT-PLB.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2024.111331DOI Listing

Publication Analysis

Top Keywords

experimental low-dose
20
conventional low-dose
20
low-dose group
20
diagnostic efficacy
12
low-dose
10
efficacy safety
8
standard-dose conventional
8
technical success
8
standard-dose group
8
group
7

Similar Publications

Background: Stroke, frequently associated with carotid artery disease, is evaluated using carotid computed tomography angiography (CTA). Dual-energy CTA (DE-CTA) enhances imaging quality but presents challenges in maintaining high image clarity with low-dose scans.

Objectives: To compare the image quality of 50 keV virtual monoenergetic images (VMI) generated using Deep Learning Image Reconstruction (DLIR) and Adaptive Statistical Iterative Reconstruction-V (ASIR-V) algorithms under a triple-low scanning protocol in carotid CTA.

View Article and Find Full Text PDF

Real-Space Quantitative Molecular Analysis at Single-Molecule Resolution.

J Am Chem Soc

September 2025

Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou 215123, Jiangsu P. R. China.

Advances in molecular analysis and characterization techniques should revolutionize the methods for scientific exploration across physics, chemistry, and biology, fundamentally overturning our understanding of interactions and processes that govern molecular behavior at the microscopic level. Currently, the absence of a molecular analysis method that can both quantify molecules and achieve single-molecule spatial resolution hinders our study of complex molecular systems in sorption and catalysis. Here, we propose a quantitative analysis strategy for small molecules confined in ZSM-5, a zeolite material extensively used in catalysis and gas separation, based on low-dose transmission electron microscopy.

View Article and Find Full Text PDF

Background: Neoantigen-based vaccines show promising therapeutic potential in solid tumors such as melanoma, GBM, NSCLC, and CRC. However, clinical responses remain suboptimal in stage IV patients, due to ineffective T-cell function and high tumor burdens. To overcome these limitations, our study investigates a combination strategy using neoantigen peptide vaccines and precision critical lesion radiotherapy (CLERT), which delivers immunomodulatory doses to key tumor regions synergistically enhance immune activation and inhibit progression in multifocal stage IV patients.

View Article and Find Full Text PDF

Optimization of carotid CT angiography image quality with deep learning image reconstruction with high setting (DLIR-H) algorithm under ultra-low radiation and contrast agent conditions.

Radiography (Lond)

September 2025

Department of Radiology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, 221002, China; School of Medical Imaging, Xuzhou Medical University, Xuzhou, Jiangsu, 221002, China; Jiangsu Provincial Engineering Research Center for Medical Imaging and Digital Medicine, Xuzhou, Jiangs

Introduction: Carotid artery disease is a major cause of stroke and is frequently evaluated using Carotid CT Angiography (CTA). However, the associated radiation exposure and contrast agent use raise concerns, particularly for high-risk patients. Recent advances in Deep Learning Image Reconstruction (DLIR) offer new potential to enhance image quality under low-dose conditions.

View Article and Find Full Text PDF