98%
921
2 minutes
20
Aims: Transcatheter aortic valve replacement (TAVR) has become the standard of care for selected patients with severe aortic stenosis. Multidetector computed tomography (MDCT) and transoesophageal 2D/3D (two-dimensional/three-dimensional) echocardiography (ECHO) are used for aortic annulus (AA) sizing. The aim of this study was to compare the accuracy of AA sizing by ECHO versus MDCT for Edwards Sapien balloon expandable valve in a single center.
Methods And Results: Data from 145 consecutive patients with TAVR (Sapien XT or Sapien S3) were analyzed retrospectively. A total of 139 (96%) patients had favorable outcomes after TAVR (at most mild aortic regurgitation and only one valve implanted). The 3D ECHO AA area and area-derived diameter were smaller than the corresponding MDCT parameters (464 ± 99 vs. 479 ± 88 mm , p < .001, and 24.2 ± 2.7 vs. 25.0 ± 5.5 mm, p = .002, respectively). The 2D ECHO annulus measurement was smaller than both the MDCT and 3D ECHO area-derived diameters (22.6 ± 2.9 vs. 25.0 ± 5.5 mm, p = .013, and 22.6 ± 2.9 vs. 24.2 ± 2.7 mm, p < .001, respectively) but larger than the minor axis diameter of the AA derived from MDCT and 3D ECHO by multiplanar reconstruction (p < .001). The 3D ECHO circumference-derived diameter was also smaller than the MDCT circumference-derived diameter (24.3 ± 2.5 vs. 25.0 ± 2.3, p = .007). The sphericity index by 3D ECHO was smaller than that by MDCT (1.2 ± .1 vs. 1.3 ± .1, p < .001). In up to 1/3 of the patients, 3D ECHO measurements would have predicted different (generally smaller) valve size than was the valve size implanted with favorable result. The concordance of the implanted valve size with the recommended size based on preprocedural MDCT and 3D ECHO AA area was 79.4% versus 61% (p = .001), and for the area-derived diameter, the concordance was 80.1% versus 61.7% (p = .001). 2D ECHO diameter concordance was similar to MDCT (78.7%).
Conclusions: 3D ECHO AA measurements are smaller than MDCT measurements. If 3D ECHO-based parameters alone are used to size the Edwards Sapien balloon expandable valve, then the selected valve size would have been smaller than the valve size implanted with favorable result in 1/3 of the patients. MDCT preprocedural TAVR assessment should be the preferred method over 3D ECHO in routine clinical practice to determine Edwards Sapien valve size.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/echo.15643 | DOI Listing |
JMIR Med Inform
September 2025
Departments of Radiology, The Third Affiliated Hospital, Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, Guangdong, 510630, China, 86 18922109279, 86 20852523108.
Background: Despite the Coronary Artery Reporting and Data System (CAD-RADS) providing a standardized approach, radiologists continue to favor free-text reports. This preference creates significant challenges for data extraction and analysis in longitudinal studies, potentially limiting large-scale research and quality assessment initiatives.
Objective: To evaluate the ability of the generative pre-trained transformer (GPT)-4o model to convert real-world coronary computed tomography angiography (CCTA) free-text reports into structured data and automatically identify CAD-RADS categories and P categories.
Neuro Endocrinol Lett
September 2025
Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, China.
Background: Pheochromocytomas and paragangliomas (PPGLs) are rare catecholamine-secreting neuroendocrine tumors originating from the embryonic neural crest. Approximately 30% of PPGLs are hereditary and are frequently associated with genetic syndromes, including neurofibromatosis type 1 (NF1). Composite PPGLs, which include components of both PPGLs and related tumors such as ganglioneuromas, are extremely rare in NF1 patients.
View Article and Find Full Text PDFJ Craniofac Surg
September 2025
Department of Otolaryngology-Head and Neck Surgery, Xijing Hospital, Air Force Military Medical University, Xi'an, China.
Salivary duct carcinoma (SDC) is a rare high-grade parotid malignancy prone to perineural spread. However, perineural spread of SDC has rarely been reported. The case of a 46-year-old male with SDC spread along the facial nerve (FN) is presented here.
View Article and Find Full Text PDFBraz Oral Res
September 2025
Ankara University, Faculty of Dentistry, Department of Oral and Maxillofacial Radiology, Ankara, Turkey.
The aim of this in-vitro study was to verify which field of view (FOV) in cone-beam computed tomography (CBCT) yields greater accuracy in the detection of internal root resorption (IRR) volume, in comparison to the gold standard of micro-computed tomography (micro-CT) and to a physical method. Twenty-five extractedsingle-rooted teeth were scanned by CBCT with two different FOV parameters (6x6-FOV and 10x10-FOV) and via micro-CT. The volume of dental hard tissue was measured on these images.
View Article and Find Full Text PDFIntroduction: Visceral adipose tissue (VAT) is a significant driver for metabolic disease risk. Low dose computed tomography (LDCT) imaging obtained for other clinical indications is useful for the opportunistic screening of osteoporosis and demonstrates additional potential for the screening of metabolic risk through the measurement of visceral adipose tissue. In this study, we explored LDCT-derived VAT and calculated VAT thresholds indicative of elevated metabolic risk in a population cohort of Chinese men and women.
View Article and Find Full Text PDF