98%
921
2 minutes
20
embryos have been widely used to study cellular processes and developmental regulation at early stages. However, most existing microfluidic devices focus on the studies of larval or adult worms rather than embryos. To accurately study the real-time dynamics of embryonic development under different conditions, many technical barriers must be overcome; these can include single-embryo sorting and immobilization, precise control of the experimental environment, and long-term live imaging of embryos. This paper reports a spiral microfluidic device for effective sorting, trapping, and long-term live imaging of single embryos under precisely controlled experimental conditions. The device successfully sorts embryos from a mixed population of at different developmental stages via Dean vortices generated inside a spiral microchannel and traps the sorted embryos at single-cell resolution through hydrodynamic traps on the sidewall of the spiral channel for long-term imaging. Through the well-controlled microenvironment inside the microfluidic device, the response of the trapped embryos to mechanical and chemical stimulation can be quantitatively measured. The experimental results show that a gentle hydrodynamic force would induce faster growth of embryos, and embryos developmentally arrested in the high-salinity solution could be rescued by the M9 buffer. The microfluidic device provides new avenues for easy, rapid, high-content screening of embryos.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9943735 | PMC |
http://dx.doi.org/10.1038/s41378-023-00485-4 | DOI Listing |
Proc Natl Acad Sci U S A
September 2025
Department of Medical and Molecular Genetics, Indiana University School of Medicine, Indianapolis, IN 46202.
Retinal ganglion cells (RGCs) are highly compartmentalized neurons whose long axons serve as the sole connection between the eye and the brain. In both injury and disease, RGC degeneration occurs in a similarly compartmentalized manner, with distinct molecular and cellular responses in the axonal and somatodendritic regions. The goal of this study was to establish a microfluidic-based platform to investigate RGC compartmentalization in both health and disease states.
View Article and Find Full Text PDFLab Chip
September 2025
Institute of Integrated Research, Institute of Science Tokyo, R2-9, 4259 Nagatsuta-cho, Midoriku, Yokohama, Kanagawa 226-8501, Japan.
Tunability in isolating target cells of varying sizes from complex heterogeneous samples is essential for biomedical research and diagnostics. However, conventional deterministic lateral displacement (DLD) systems lack flexibility due to their fixed critical diameters (). Here, we present a thermo-responsive DLD micropillar array that enables tunable cell separation by dynamically modulating through temperature control.
View Article and Find Full Text PDFFood Res Int
November 2025
Medical School of Nantong University, Nantong 226001, China. Electronic address:
Food nutrition and safety are fundamental to the food industry, and the development of appropriate research models is crucial. Unlike traditional animal models, the innovative organoid/organ-on-a-chip model possess distinct human-like characteristics and genomic stability, which have garnered significant attention in food research. In this review, we conduct a comparative analysis between organoids and traditional animal and 2D cell models.
View Article and Find Full Text PDFFood Res Int
November 2025
Key Laboratory of Environmental Related Diseases and One Health, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, China. Electronic address:
This study aimed to investigate the protective mechanism of Osmanthus fragrans water extract (OSF) against liver injury induced by dibutyl phthalate (DBP). We utilized liver organoids and liver organ chip technology to replicate the liver microenvironment in vivo. Metabolomic analysis revealed that DBP induced oxidative stress and lipid metabolism disorders; however, following intervention with OSF, the associated abnormal metabolites were significantly reduced.
View Article and Find Full Text PDFNat Commun
September 2025
Department of Chemical Science and Engineering, School of Materials and Chemical Technology, Institute of Science Tokyo, Nagatsuta-cho, Midori-ku, Yokohama, Japan.
The research and implementation of portable and low-cost analytical devices that possess high reproducibility and ease of operation is still a challenging task, and a growing field of importance, within the analytical research. Herein, we report the concept, design and optimization of a microfluidic device based on electrochemiluminescence (ECL) detection that can be potentially operated without electricity for analytical purposes. The device functions exploiting the concept of streaming potential-driven bipolar electrochemistry, where a potential difference, generated from the flow of an electrolyte through a microchannel under the influence of a pressure gradient, is the driving force for redox reactions.
View Article and Find Full Text PDF