Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Lymphovascular invasion (LVI) is a relevant prognostic factor in germ cell tumors of the testis (GCTT), and it is included in the pT stage. However, its detection on hematoxylin and eosin (H&E) slides is very challenging, and previous studies reported fair to moderate inter-observer agreement among dedicated uropathologists. In the present study, we tested H&E and a recently developed in-house double staining for OCT4/CD34 to detect LVI in GCTT.

Methods: Nine authors [5 non-uropathologists and 4 uropathologists] independently evaluated 34 consecutive and retrospectively enrolled cases of GCTT. We assessed the inter-observer agreement (Fleiss's Kappa) with both H&E and OCT4/CD34. Besides, we compared the consensus diagnosis on both H&E and OCT4/CD34-stained sections with the original diagnosis to evaluate the pT re-staging (McNemar test) and identify the sources of disagreement.

Results: The inter-observer agreement among uropathologists plus non-uropathologists was fair with both H&E (KF=0.398; p < 0.001) and OCT4/CD34 (KF=0.312; p < 0.001). OCT4/CD34 (KF=0.290; p < 0.001) slightly reduces the inter-observer agreement compared to H&E (KF=0.321; p < 0.001) for non-uropathologists; in contrast, OCT4/CD34 (KF=0.293; p < 0.001) significantly reduces the inter-observer agreement compared to H&E (KF=0.529; p < 0.001) for uropathologists, changing it from moderate to fair. Consensus diagnosis with H&E modified the LVI status of the original diagnosis in 8/34 (23.5 %) cases (p: 0.070), with pT re-staging in 2/34 (5.9 %) cases (p: 0.500). Consensus diagnosis with OCT4/CD34 modified the LVI status of the original diagnosis in 8/34 (23.5 %) cases (p: 0.289), with pT re-staging in 3/34 (8.8 %) cases (p: 0.250). The consensus diagnosis with OCT4/CD34 modified the consensus diagnosis with H&E in 8/34 (23.5 %) cases (p: 0.727), and these findings resulted in pT-restaging in 3/34 (8.8 %) cases (p: 0.500). The sources of disagreement among uropathologists were: H&E [artefactual clefts misinterpreted as LVI in 4/6 (66.7 %) cases and true foci of LVI misinterpreted as clusters of histiocytes within the vessels in 2/6 (33.3 %) cases], OCT4/CD34 [artefactual clefts misinterpreted as LVI in 2/8 (25 %) cases, true LVI misinterpreted as artefactual clefts in 2/8 (25 %) cases or floaters in 4/8 (50 %) cases].

Conclusions: OCT4/CD34 does not improve the inter-observer agreement for the assessment of LVI in OCT4(+) GCTT. Consensus diagnosis with H&E modifies the LVI status in a significant number of cases, resulting in changes of the pT stage in a relatively small subgroup. Consensus diagnosis with OCT4/CD34 provides little additional benefit since it cannot exclude mimickers of LVI such as floaters and artefactual clefts. These results argue against the adoption of this diagnostic tool for the routine assessment of OCT4(+) GCTT.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prp.2023.154337DOI Listing

Publication Analysis

Top Keywords

inter-observer agreement
12
h&e oct4/cd34
8
h&e
6
oct4/cd34 assessment
4
assessment lympho-vascular
4
lympho-vascular invasion
4
invasion seminoma
4
seminoma embryonal
4
embryonal carcinoma
4
carcinoma background
4

Similar Publications

Renal Resistive Index (RRI) and Renal Pulsatility Index (RPI) are currently used in the diagnosis of ureteral obstruction, early diagnosis and follow-up of acute kidney injury, assessment of chronic kidney disease, and evaluation of transplanted kidneys. However, their inter-observer and inter-scanner variability has not been investigated in dogs, limiting the accuracy and clinical applicability of these indices. The objectives of this cross-sectional observational prospective study were to assess the inter-observer and inter-scanner variability of RRI and RPI and to determine whether operator experience influences measurement accuracy.

View Article and Find Full Text PDF

Background: A significant contributory factor to the brachycephalic obstructive airway syndrome index of bulldogs is the diameter of their tracheas. Bulldogs are predisposed to tracheal hypoplasia. A non-invasive, financially reasonable and widely accessible screening test for tracheal diameter would be useful for assessing the most appropriate dogs to breed from within bulldog populations and may help in predicting results following upper airway surgery.

View Article and Find Full Text PDF

Background: Low-field MRI provides superior soft-tissue contrast compared to CT while costing significantly less than high-field MRI, which makes it a more accessible option for MRI-guided radiation therapy planning. Four-dimensional MRI (4D-MRI) is a technique that has been increasingly adopted clinically for internal target volume (ITV) delineation in free-breathing liver radiotherapy planning, and it requires high spatial resolution and accurate respiratory phase differentiation to enable precise dose planning. The feasibility of 4D-MRI at low-field strength, specifically at 0.

View Article and Find Full Text PDF

Background: Screw fixation is pivotal for prosthetic stability. For 3D-printed customized acetabular revision prostheses designed for complex, large-scale bone defects, precise adherence to preoperative screw trajectory planning is critical. However, there remains a lack of standardized three-dimensional (3D) evaluation protocols to quantify intraoperative screw angular alignment fidelity relative to preoperative digital plans, hindering universal validation criteria.

View Article and Find Full Text PDF

A multicenter study on the comparability of myocardial strain values acquired with different CMR scanners and analyzed with different post-processing software: insights into the "Traveling Volunteers" study.

Int J Comput Assist Radiol Surg

August 2025

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Campus Virchow-Klinikum Augustenburger Platz 1, 13353, Berlin, Germany.

Purpose: Strain quantifies myocardial deformation. Despite its high diagnostic value, strain analyses using cardiovascular magnetic resonance (CMR) feature tracking (FT) have not been fully implemented into clinical routine due to lack of information on reproducibility. The purpose of this study was to assess the comparability of cardiovascular magnetic resonance CMR FT strain and ejection fraction (EF) measurements, obtained from different MR scanners and analyzed using different software platforms.

View Article and Find Full Text PDF