Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Renal Resistive Index (RRI) and Renal Pulsatility Index (RPI) are currently used in the diagnosis of ureteral obstruction, early diagnosis and follow-up of acute kidney injury, assessment of chronic kidney disease, and evaluation of transplanted kidneys. However, their inter-observer and inter-scanner variability has not been investigated in dogs, limiting the accuracy and clinical applicability of these indices. The objectives of this cross-sectional observational prospective study were to assess the inter-observer and inter-scanner variability of RRI and RPI and to determine whether operator experience influences measurement accuracy. RRI and RPI were measured in the left kidney of 10 client-owned dogs by four different operators with varying levels of experience, using two different ultrasound scanners. The intraclass correlation coefficient (ICC) between the two ultrasound scanners for both RRI and RPI were good to excellent in all four observers (ICC > 0.75 and p < 0.05). Similarly, a good to excellent correlation coefficient was observed between the measurements of the four operators for both indices across each ultrasound scanner (ICC > 0.75 and p < 0.05). These findings indicate that RRI and RPI are feasible and reproducible measurements with good inter-scanner and inter-observer agreement, regardless of operator experience. However, achieving high reproducibility requires adequate training and the use of a standardized protocol with strict but adaptable settings tailored to each patient's characteristics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rvsc.2025.105882DOI Listing

Publication Analysis

Top Keywords

inter-observer inter-scanner
12
inter-scanner variability
12
rri rpi
12
renal resistive
8
renal pulsatility
8
ultrasound scanners
8
determination inter-observer
4
variability measurement
4
renal
4
measurement renal
4

Similar Publications

Renal Resistive Index (RRI) and Renal Pulsatility Index (RPI) are currently used in the diagnosis of ureteral obstruction, early diagnosis and follow-up of acute kidney injury, assessment of chronic kidney disease, and evaluation of transplanted kidneys. However, their inter-observer and inter-scanner variability has not been investigated in dogs, limiting the accuracy and clinical applicability of these indices. The objectives of this cross-sectional observational prospective study were to assess the inter-observer and inter-scanner variability of RRI and RPI and to determine whether operator experience influences measurement accuracy.

View Article and Find Full Text PDF

A multicenter study on the comparability of myocardial strain values acquired with different CMR scanners and analyzed with different post-processing software: insights into the "Traveling Volunteers" study.

Int J Comput Assist Radiol Surg

August 2025

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Campus Virchow-Klinikum Augustenburger Platz 1, 13353, Berlin, Germany.

Purpose: Strain quantifies myocardial deformation. Despite its high diagnostic value, strain analyses using cardiovascular magnetic resonance (CMR) feature tracking (FT) have not been fully implemented into clinical routine due to lack of information on reproducibility. The purpose of this study was to assess the comparability of cardiovascular magnetic resonance CMR FT strain and ejection fraction (EF) measurements, obtained from different MR scanners and analyzed using different software platforms.

View Article and Find Full Text PDF

Background: Multiple sclerosis (MS) is one of the most common disabling central nervous system diseases affecting young adults. Magnetic resonance imaging (MRI) is an essential tool for diagnosing and following up multiple sclerosis. Over the years, many MRI techniques have been developed to improve the sensitivity of MS disease detection.

View Article and Find Full Text PDF

Purpose: To explore the variation of the discriminative power of CT (Computed Tomography) radiomic features (RF) against image discretization/interpolation in predicting early distant relapses (EDR) after upfront surgery.

Materials And Methods: Data of 144 patients with pre-surgical high contrast CT were processed consistently with IBSI (Image Biomarker Standardization Initiative) guidelines. Image interpolation/discretization parameters were intentionally changed, including cubic voxel size (0.

View Article and Find Full Text PDF

4D PC MRI of the aorta has become a routinely available examination, and a multitude of single parameters have been suggested for the quantitative assessment of relevant flow features for clinical studies and diagnosis. However, clinically applicable assessment of complex flow patterns is still challenging. We present a concept for applying radiomics for the quantitative characterization of flow patterns in the aorta.

View Article and Find Full Text PDF