Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Screening, monitoring, and diagnosis are critical in oncology treatment. However, there are limitations with the current clinical methods, notably the time, cost, and special facilities required for radioisotope-based methods. An alternative approach, which uses magnetic beads, offers faster analyses with safer materials over a wide range of oncological applications. Magnetic beads have been used to detect extracellular vesicles (EVs) in the serum of pancreatic cancer patients with statistically different EV levels in preoperative, postoperative, and negative control samples. By incorporating fluorescence, magnetic beads have been used to quantitatively measure prostate-specific antigen (PSA), a prostate cancer biomarker, which is sensitive enough even at levels found in healthy patients. Immunostaining has also been incorporated with magnetic beads and compared with conventional immunohistochemical methods to detect lesions; the results suggest that immunostained magnetic beads could be used for pathological diagnosis during surgery. Furthermore, magnetic nanoparticles, such as superparamagnetic iron oxide nanoparticles (SPIONs), can detect sentinel lymph nodes in breast cancer in a clinical setting, as well as those in gallbladder cancer in animal models, in a surgery-applicable timeframe. Ultimately, recent research into the applications of magnetic beads in oncology suggests that the screening, monitoring, and diagnosis of cancers could be improved and made more accessible through the adoption of this technology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8774179PMC
http://dx.doi.org/10.3390/cancers14020364DOI Listing

Publication Analysis

Top Keywords

magnetic beads
24
magnetic nanoparticles
8
screening monitoring
8
monitoring diagnosis
8
applications magnetic
8
magnetic
7
beads
6
application magnetic
4
nanoparticles rapid
4
rapid detection
4

Similar Publications

A MAGNETIC BEAD-BASED FLUORESCENT SUBSTRATE FOR SENSITIVE ASSAY OF SARS-CoV-2 3C-LIKE PROTEASE ACTIVITY.

Protein Expr Purif

September 2025

Key Laboratory of Enzyme and Protein Technology, VNU University of Science, Vietnam National University, Hanoi, 334 Nguyen Trai, Thanh Xuan, Hanoi, Vietnam; Faculty of Biology, VNU University of Science, Vietnam National University, Hanoi, 334 Nguyen Trai, Thanh Xuan, Hanoi, Vietnam. Electronic addr

The 3C-like protease (3CLpro) of SARS-CoV-2 is a crucial target for antiviral drugs due to its essential role in viral polyprotein processing. In this study, we designed and produced a modular fluorescent recombinant substrate (6×His-ECFP-AVLQSGFRK-EYFP), which was then immobilized on Ni-NTA magnetic beads (Ni-NTA-6×His-ECFP-AVLQSGFRK-EYFP) for the assay of 3CLpro activity. Upon cleavage at the specific AVLQ↓SG motif, the EYFP fragment was released into the supernatant and quantified via fluorescence measurement (Ex/Em = 480/528 nm).

View Article and Find Full Text PDF

A single-molecule biosensor based on multiple fluorophore nucleic acid probe and STORM imaging for detection of Hantaan virus.

Talanta

August 2025

School of Public Health &Jiangxi Provincial Key Laboratory of Disease Prevention and Public Health, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, 330031, PR China. Electronic address:

Hemorrhagic fever with renal syndrome (HFRS), caused by Hantaan virus, poses a serious public health threat. Current diagnostic methods remain limited by low sensitivity, complex procedures, and high sample requirements. To address this, we developed a highly sensitive single-molecule biosensor using multi-fluorophore nucleic acid probes and STORM imaging for the detection of Hantaan virus RNA.

View Article and Find Full Text PDF

Rational design of an ultra-high-gain MoS phototransistor enabling room-temperature detection of few-photon signals and attomolar-level immunosensing.

Sci Bull (Beijing)

August 2025

Key Laboratory for Micro/Nano Optoelectronic Devices of Ministry of Education & Hunan Provincial Key Laboratory of Low-Dimensional Structural Physics and Devices, School of Physics and Electronics, Hunan University, Changsha 410082, China. Electronic address:

Determining the number of photons in an incident light pulse at room temperature is the ultimate goal of photodetection. Herein, we report a plasmon-strain-coupled tens of photon level phototransistor by integrating monolayer MoS on top of Au nanowire (NW). Within this structure, Au NW can greatly enhance incident light intensity around MoS, and the large tensile strain can reduce the contact energy barrier between MoS and Au NW, so as to achieve efficient injection of plasmonic hot electrons into MoS.

View Article and Find Full Text PDF

Background: Magnetic particles (MPs) are widely used in bioanalytical systems to quickly separate specific targets from complex samples using a magnetic field. MPs can be easily functionalized with bioreceptors to capture, separate, and concentrate biomarkers like proteins, oligonucleotides, and cells. Combining MPs-separation capabilities with electrochemical sensors can greatly enhance the sensitivity of these devices, helping achieve ultralow limits of detection for biomarkers.

View Article and Find Full Text PDF

In vitro fertilization (IVF) faces challenges in evaluating embryo quality and in determining the genetic health of embryos. Key biomarkers in the culture medium, including nucleic acids and proteins, offer promising avenues for noninvasive assessment. However, small sample volumes, low biomolecule concentrations, and potential contaminants complicate the reliable detection of genetic indicators.

View Article and Find Full Text PDF