Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cardiac diffusion tensor imaging (DTI) is an emerging technique for the in vivo characterisation of myocardial microstructure, and there is a growing need for its validation and standardisation. We sought to establish the accuracy, precision, repeatability and reproducibility of state-of-the-art pulse sequences for cardiac DTI among 10 centres internationally. Phantoms comprising 0%-20% polyvinylpyrrolidone (PVP) were scanned with DTI using a product pulsed gradient spin echo (PGSE; N = 10 sites) sequence, and a custom motion-compensated spin echo (SE; N = 5) or stimulated echo acquisition mode (STEAM; N = 5) sequence suitable for cardiac DTI in vivo. A second identical scan was performed 1-9 days later, and the data were analysed centrally. The average mean diffusivities (MDs) in 0% PVP were (1.124, 1.130, 1.113) x 10  mm /s for PGSE, SE and STEAM, respectively, and accurate to within 1.5% of reference data from the literature. The coefficients of variation in MDs across sites were 2.6%, 3.1% and 2.1% for PGSE, SE and STEAM, respectively, and were similar to previous studies using only PGSE. Reproducibility in MD was excellent, with mean differences in PGSE, SE and STEAM of (0.3 ± 2.3, 0.24 ± 0.95, 0.52 ± 0.58) x 10  mm /s (mean ± 1.96 SD). We show that custom sequences for cardiac DTI provide accurate, precise, repeatable and reproducible measurements. Further work in anisotropic and/or deforming phantoms is warranted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9285553PMC
http://dx.doi.org/10.1002/nbm.4685DOI Listing

Publication Analysis

Top Keywords

cardiac dti
12
pgse steam
12
cardiac diffusion
8
diffusion tensor
8
tensor imaging
8
sequences cardiac
8
spin echo
8
x 10  mm
8
dti
5
pgse
5

Similar Publications

Multi-centre Investigation of Cardiac Diffusion Tensor Imaging in Healthy Volunteers by SCMR Cardiac Diffusion Special Interest Group NETwork (SIGNET).

J Cardiovasc Magn Reson

August 2025

Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland; Center for Preclinical Development, University of Zurich and University Hospital Zurich, Zurich, Switzerland.

Background: Cardiac diffusion tensor imaging (cDTI) is an emerging technique for microstructural characterization of the heart and has shown clinical potential in a range of cardiomyopathies. However, there is substantial variation reported for in vivo cDTI results across the literature, and sensitivity of cDTI to differences in imaging sites, scanners, acquisition protocols and post-processing methods remains incompletely understood.

Methods: SIGNET is a prospective multi-centre, observational study in travelling and non-travelling healthy volunteers.

View Article and Find Full Text PDF

Recent neuroscience research has shed light on heart-brain interactions during diverse information processes across perception, affective, and cognitive domains. It remains unclear how the heartbeat-related interoceptive pathway affects the neural responses of somatosensory information processing. In this study, we combined EEG, ECG, and DTI to examine the effect of heart-brain interaction on cortical somatosensory processing and investigated both the cardiac phase and heart rate effects on somatosensory-evoked high-frequency oscillations (HFOs).

View Article and Find Full Text PDF

Objective: This study aimed to examine the characteristics of cognitive impairment in individuals with white matter hyperintensities (WMH) and to compare differences in cognitive dysfunction across varying levels of WMH severity.

Methods: A total of 100 participants were randomly recruited from inpatient and outpatient departments of a hospital between November 2018 and December 2022. The cohort included 55 patients with cerebral small vessel disease (CSVD) and 45 control participants without CSVD.

View Article and Find Full Text PDF

Diffusion-weighted imaging (DWI) is a key contrast mechanism in MRI which allows for the assessment of microstructural properties of brain tissues by measuring the displacement of water molecules. Several diffusion models, including the tensor (DTI), kurtosis (DKI), and neurite orientation dispersion and density imaging (NODDI), are commonly used in both research and clinical practice. However, there is currently no standardized method for validating the stability and repeatability of these models over time.

View Article and Find Full Text PDF

Background: Cerebral white matter (WM) injury after ischemic stroke is associated with post-stroke cognitive impairment (PSCI), however, the interaction between sustained neuroinflammation and post-stroke WM injury is not well understood. Hybrid PET/MRI can provide insight into pathophysiological mechanisms linking chronic neuroinflammation, ischemic WM injury, and PSCI. Using PET/MRI, this study investigated the relationship between [F]FEPPA standardized uptake value ratio (SUVr) measurements of glial activation and diffusion tensor imaging (DTI) measurements of microstructure integrity in brain WM regions in the chronic phase at 6-months after acute ischemic stroke.

View Article and Find Full Text PDF