Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Plant root angle determines the vertical and horizontal distribution of roots in the soil layer, which further influences the acquisition of phosphorus (P) in topsoil. Large genetic variability for the lateral root angle (root angle) was observed in a linkage mapping population (TNDH population) and an association panel of whether at a low P (LP) or at an optimal P (OP). At LP, the average root angle of both populations became smaller. Nine quantitative trait loci (QTLs) at LP and three QTLs at OP for the root angle and five QTLs for the relative root angle (RRA) were identified by the linkage mapping analysis in the TNDH population. Genome-wide association studies (GWASs) revealed 11 single-nucleotide polymorphisms (SNPs) significantly associated with the root angle at LP (LPRA). The interval of a QTL for LPRA on A06 () overlapped with the confidence region of the leading SNP () significantly associated with LPRA. In addition, a QTL cluster on chromosome C01 associated with the root angle and the primary root length (PRL) in the "pouch and wick" high-throughput phenotyping (HTP) system, the root P concentration in the agar system, and the seed yield in the field was identified in the TNDH population at LP. A total of 87 genes on A06 and 192 genes on C01 were identified within the confidence interval, and 14 genes related to auxin asymmetric redistribution and root developmental process were predicted to be candidate genes. The identification and functional analyses of these genes affecting LPRA are of benefit to the cultivar selection with optimal root system architecture (RSA) under P deficiency in .

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8358456PMC
http://dx.doi.org/10.3389/fpls.2021.697872DOI Listing

Publication Analysis

Top Keywords

root angle
36
root
13
tndh population
12
angle
9
linkage mapping
8
associated root
8
genes
5
genetic dissection
4
dissection root
4
angle response
4

Similar Publications

Purpose: This study aims to address the limitations of radiographic imaging and single-task learning models in adolescent idiopathic scoliosis assessment by developing a noninvasive, radiation-free diagnostic framework.

Methods: A multi-task deep learning model was trained using structured back surface data acquired via fringe projection three-dimensional imaging. The model was designed to simultaneously predict the Cobb angle, curve type (thoracic, lumbar, mixed, none), and curve direction (left, right, none) by learning shared morphological features.

View Article and Find Full Text PDF

This study evaluates the accuracy of single camera markerless motion capture (SCMoCap) using Microsoft's Azure Kinect, enhanced with inverse kinematics (IK) via OpenSim, for upper limb movement analysis. Twelve healthy adults performed ten upper-limb tasks, recorded simultaneously by OptiTrack (marker-based) and Azure Kinect (markerless) from frontal and sagittal views. Joint angles were calculated using two methods: (1) direct kinematics based on body coordinate frames and (2) inverse kinematics using OpenSim's IK tool with anatomical keypoints.

View Article and Find Full Text PDF

Radiological Comparison of Piezosurgery and Classical Osteotomies in Rhinoplasty.

Aesthetic Plast Surg

September 2025

Department of Otorhinolaryngology, Faculty of Medicine, Kırıkkale University, 71450, Yahşihan, Kırıkkale, Turkey.

Objective: The aim of this study is to compare the radiological measurements of patients who underwent rhinoplasty using a piezo device with those of patients who underwent rhinoplasty using a classical osteotome.

Methods: A total of 60 patients were included in the study: 30 rhinoplasty patients who underwent piezosurgical osteotomy and 30 who underwent classical osteotomy. Preoperative and postoperative functional and aesthetic outcomes were compared using NOSE and ROE scores.

View Article and Find Full Text PDF

Inertial Measurement Units (IMUs) enable accurate estimation of anatomical joint angles but require a sensor-to-segment calibration. Literature has presented several algorithms that address this gap; however, adequately comparing calibration performance is not trivial. This study compares 3 calibration methods: N-pose calibration (NP), functional calibration (FC), and manual alignment (MA) to estimate 3D wrist joint angles during single-plane and multiplane tasks.

View Article and Find Full Text PDF

Background: Electron paramagnetic resonance imaging (EPRI)-based oxygen imaging technology enables adaptive radiation therapy, thereby improving tumor control rates. However, the long scanning time limits the development of EPRI. In this study, we endeavored to reduce the scanning time.

View Article and Find Full Text PDF