Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Temporomandibular joint (TMJ) disorders disproportionally affect females, with female to male prevalence varying from 3:1 to 8:1. Sexual dimorphisms in masticatory muscle attachment morphometry and association with craniofacial size, critical for understanding sex-differences in TMJ function, have not been reported. The objective of this study was to determine sex-specific differences in three-dimensional (3D) TMJ muscle attachment morphometry and craniofacial sizes and their impact on TMJ mechanics. Human cadaveric TMJ muscle attachment morphometry and craniofacial anthropometry (10Males; 11Females) were determined by previously developed 3D digitization and imaging-based methods. Sex-differences in muscle attachment morphometry and craniofacial anthropometry, and their correlation were determined, respectively using multivariate general linear and linear regression statistical models. Subject-specific musculoskeletal models of the mandible were developed to determine effects of sexual dimorphisms in mandibular size and TMJ muscle attachment morphometry on joint loading during static biting. There were significant sex-differences in craniofacial size (p = 0.024) and TMJ muscle attachment morphometry (p < 0.001). TMJ muscle attachment morphometry was significantly correlated with craniofacial size. TMJ contact forces estimated from biomechanical models were significantly, 23% on average (p < 0.001), greater for females compared to those for males when generating the same bite forces. There were significant linear correlations between TMJ contact force and both 3D mandibular length (R = 0.48, p < 0.001) and muscle force moment arm ratio (R = 0.68, p < 0.001). Sexual dimorphisms in masticatory muscle morphology and craniofacial sizes play critical roles in subject-specific TMJ biomechanics. Sex-specific differences in the TMJ mechanical environment should be further investigated concerning mechanical fatigue of TMJ discs associated with TMJ disorders.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8453136PMC
http://dx.doi.org/10.1016/j.jbiomech.2021.110623DOI Listing

Publication Analysis

Top Keywords

muscle attachment
28
attachment morphometry
28
tmj muscle
16
sexual dimorphisms
12
morphometry craniofacial
12
masticatory muscle
8
temporomandibular joint
8
craniofacial size
8
craniofacial anthropometry
8
muscle
7

Similar Publications

Metastatic renal osteosarcoma is a rare entity. We report a case of a 52-year-old male postright nephrectomy status presented to us with metastatic renal osteosarcoma. 18-fluorine- fluorodeoxyglucose (F-FDG) avid lesions were seen in the right renal bed with extension to adjacent hepatic parenchyma.

View Article and Find Full Text PDF

Many ant species show dramatic shifts in behaviour when infected with parasites, but the molecular basis of these behavioural changes is not well understood. An example is the wood ant, Formica aserva, which serves as an intermediate host for the lancet liver fluke, Dicrocoelium dendriticum. Infected ants leave their nests during the cool hours of the day, ascend a flower and then attach themselves to a petal with their mandibles.

View Article and Find Full Text PDF

Characterization of skeletal muscle contraction using a flexible and wearable ultrasonic sensor.

Prog Mol Biol Transl Sci

September 2025

Department of Systems and Computer Engineering, Carleton University, Ottawa, ON, Canada. Electronic address:

Monitoring skeletal muscle contraction provides valuable information about the muscle mechanical properties, which can be helpful in various biomedical applications. This chapter presents a single-element flexible and wearable ultrasonic sensor (WUS) developed by our research group and its application for continuously monitoring and characterizing skeletal muscle contraction. The WUS is made from a 110-µm thick polyvinylidene fluoride piezoelectric polymer film.

View Article and Find Full Text PDF

Wound healing is an intricate physiological process, with acute and chronic wounds imposing significant burdens on the healthcare systems worldwide. This study reports the development fully biodegradable silica gel fiber (SGF) scaffolds for enhanced skin tissue regeneration. Three types of wound dressings, differing in their structure, are fabricated: pressure-spun silica gel µ-fibers (pSGF) allowing cell penetration, electrospun sub-µ silica gel fibers (eSGF) mimicking an extracellular matrix (ECM)-like sub-µ-structure with narrow mesh sizes allowing no cell ingrowth, and a hybrid scaffold combining both fiber types (peSGF) that combines the advantages of both structures.

View Article and Find Full Text PDF

S-palmitoylation has emerged as a critical integrator of lipid overload and cardiovascular dysfunction. Disordered lipid metabolism inundates endothelial cells, vascular smooth muscle cells and macrophages with triglyceriderich lipoproteins, oxidized LDL and saturated fatty acids, expanding the intracellular palmitoylCoA pool and perturbing redox balance. Protein Spalmitoylation, the reversible attachment of palmitate to cysteine residues, converts excess palmitoylCoA into broad alterations in signalling and membrane dynamics.

View Article and Find Full Text PDF