Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Accurate overlapping-peaks extraction plays a critical role in chromatic confocal thickness measurement of ultra-thin transparent film. However, the current algorithms usually appear as a perceptible extraction error resulting from the disturbing influence among peaks in the process of fitting the spectral axial response signal (sARS) of the two measuring surfaces. In this paper, we propose an adaptive modal decomposition method to extract multi peaks for the ultra-thin materials. With this method, the sARS can be firstly decomposed into several sub-modes, which can be used to obtain the peak wavelength of each measuring surface by the existing single peak extraction algorithms, such as the centroid method and Gauss fitting method. Monte Carlo simulations and experimental tests demonstrate that the proposed algorithm has significant improvements over the existing nonlinear fitting algorithms in terms of peak extraction accuracy and precision.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.410177DOI Listing

Publication Analysis

Top Keywords

adaptive modal
8
modal decomposition
8
overlapping-peaks extraction
8
thickness measurement
8
chromatic confocal
8
peak extraction
8
extraction
5
decomposition based
4
based overlapping-peaks
4
extraction thickness
4

Similar Publications

Multi-modal image analysis for large-scale cancer tissue studies within IMMUcan.

Cell Rep Methods

September 2025

Department of Quantitative Biomedicine, University of Zurich, Zurich, Switzerland; Institute of Molecular Health Sciences, ETH Zurich, Zurich, Switzerland. Electronic address:

In cancer research, multiplexed imaging allows detailed characterization of the tumor microenvironment (TME) and its link to patient prognosis. The integrated immunoprofiling of large adaptive cancer patient cohorts (IMMUcan) consortium collects multi-modal imaging data from thousands of patients with cancer to perform broad molecular and cellular spatial profiling. Here, we describe and compare two workflows for multiplexed immunofluorescence (mIF) and imaging mass cytometry (IMC) developed within IMMUcan to enable the generation of standardized data for cancer tissue analysis.

View Article and Find Full Text PDF

Optically Controlled Memristor Enabling Synergistic Sensing-Memory-Computing for Neuromorphic Vision Systems.

Adv Mater

September 2025

Key Laboratory of Brain-Like Neuromorphic Devices and Systems of Hebei Province, College of Electronic and Information Engineering, Hebei University, Baoding, 071002, China.

Neuromorphic Visual Devices hold considerable promise for integration into neuromorphic vision systems that combine sensing, memory, and computing. This potential arises from their synergistic benefits in optical signal detection and neuro-inspired computational processes. However, current devices face challenges such as insufficient light/dark resistance ratios, mismatched transient photo-response, and volatile retention characteristics, limiting their adaptability to complex artificial vision systems.

View Article and Find Full Text PDF

The global prevalence of mental health disorders among youths aged 15 to 24 is a significant public health concern. This systematic review aimed to explore global strategies for promoting mental well-being and addressing mental health challenges within this demographic, as defined by the World Health Organization. A comprehensive search of electronic scientific databases was conducted on November 1, 2023, yielding 43 studies with a total of 29,581 participants published between 2008 and 2023 that examined mental health interventions targeting youth.

View Article and Find Full Text PDF

Distinct Neural Mechanisms of Visual and Sound Adaptation in the Cat Visual Cortex.

Eur J Neurosci

September 2025

The Tampa Human Neurophysiology Lab, Department of Neurosurgery, Brain and Spine, Morsani College of Medicine, University of South Florida, Tampa, Florida, USA.

Sensory areas exhibit modular selectivity to stimuli, but they can also respond to features outside of their basic modality. Several studies have shown cross-modal plastic modifications between visual and auditory cortices; however, the exact mechanisms of these modifications are yet not completely known. To this aim, we investigated the effect of 12 min of visual versus sound adaptation (referring to forceful application of an optimal/nonoptimal stimulus to a neuron[s] under observation) on the infragranular and supragranular primary visual neurons (V1) of the cat (Felis catus).

View Article and Find Full Text PDF

Mimicking human brain functionalities with neuromorphic devices represents a pivotal breakthrough in developing bioinspired electronic systems. The human somatosensory system provides critical environmental information and facilitates responses to harmful stimuli, endowing us with good adaptive capabilities. However, current sensing technologies often struggle with insufficient sensitivity, dynamic response, and integration challenges.

View Article and Find Full Text PDF