Article Abstract

To investigate conditions that cause temporal lens opacity, we tested chemical and physical factors, such as anaesthesia dose, ocular surface dryness, and infrared (IR) light exposure in anaesthetised C57BL/6 N mice. Mice were anaesthetised with a low (80%; tiletamine/zolazepam 32 mg/kg and xylazine 8 mg/kg, intraperitoneal injection) or high (120%; 48 mg/kg and 12 mg/kg) dose of anaesthetic and examined every 5 min from 10 to 30 min after anaesthesia was induced. Lens opacity levels were assessed and graded (1-6) using the standard classification system. Regardless of the anaesthetic dose, lens opacity grade was 1-2 in moisturised eyes with application of 0.5% carboxymethylcellulose, and 5-6 in dry ocular surface conditions. Lens opacity in mice with high-dose anaesthetic in the dry ocular surface condition was not different from that of mice with low-dose anaesthetic. Lens opacity grade 1-2 was noted in eyes in the wet ocular surface condition, regardless of IR light exposure. During IR light exposure in eyes in the dry ocular surface condition, lens opacity (grade 6) in mice with high-dose anaesthetic was not different from that (grade 6) in mice with low-dose anaesthetic. We demonstrated that ocular surface dryness might be a relevant factor for the formation and progression of lens opacity in anesthetized C57BL/6 N mice. Anaesthesia dose and IR light exposure did not strongly influence lens opacity formation. Furthermore, eyes with corneal dryness-induced lens opacity recovered to normal status without additional intervention.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7081593PMC
http://dx.doi.org/10.1186/s42826-019-0031-zDOI Listing

Publication Analysis

Top Keywords

lens opacity
40
ocular surface
24
light exposure
16
opacity grade
12
dry ocular
12
surface condition
12
lens
10
opacity
10
mice
8
anaesthesia dose
8

Similar Publications

Age-related eye diseases (AREDs) are the leading cause of visual impairment in the elderly, affecting the structure of the anterior and posterior segments of the eye, significantly reducing the quality of life of patients, and even leading to irreversible blindness. Typical AREDs include age-related cataract (ARC), dry eye disease (DED), age-related macular degeneration (AMD), glaucoma, and diabetic retinopathy (DR), the global prevalence of which continues to rise, becoming a serious public health concern. SIRT1 is an NAD + dependent deacetylase, which plays an important physiological regulatory role in ocular tissues, mainly affecting gene expression and various cellular processes by regulating the acetylation status of substrate proteins.

View Article and Find Full Text PDF

Low-Energy Femtosecond Laser Lens Fragmentation Techniques for Cataract.

Exp Eye Res

September 2025

Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics_Huazhong University of Science and Technology, Wuhan 430074, China; MOE Key Laboratory for Biomedical Photonics, Department of Biomedical Engineering, College of Life Science and Technology, Advanced Biomed

Femtosecond laser has become an important tool in cataract surgery due to its precision and minimally invasive nature. However, the strong scattering properties of the lens limit surgical efficiency, especially when it comes to effectively cutting highly opaque and hard cataracts with femtosecond laser. This study proposes a method for achieving optical transparency in opaque lenses through tartrazine treatment.

View Article and Find Full Text PDF

Purpose: To assess the clinical outcomes of Hydrus Microstent implantation with cataract extraction for the treatment of open angle glaucoma (OAG) over a maximum of 4 years.

Design: Retrospective, single-center, single-arm, longitudinal cohort study.

Subjects: 308 patients (464 eyes) with OAG who underwent Hydrus Microstent implantation with cataract extraction between February 2019 and December 2021, followed for a median (interquartile range, IQR) of 2.

View Article and Find Full Text PDF

Correlations Between Variability of Preoperative Ocular Biometric Measurements and Accuracy of Intraocular Lens Power Calculation.

Photodiagnosis Photodyn Ther

September 2025

Department of Ophthalmology, The People's Hospital of Baoan Shenzhen, Shenzhen 518000, China; Department of Ophthalmology, The Second Affiliated Hospital of Shenzhen University, Shenzhen 518000, China. Electronic address:

Objectives: To investigate the relationship between variability of preoperative ocular biometric measurements and the accuracy of intraocular lens (IOL) power calculation.

Methods: This retrospective study included cataract patients who underwent surgery at the People's Hospital of Baoan Shenzhen from January 2022 to December 2024. Preoperative ocular biometric parameters were measured using the Lenstar LS-900, and the coefficients of variation (CV) of corneal curvature (K1-CV, K2-CV), axial length (AL-CV), anterior chamber depth (ACD-CV) were calculated.

View Article and Find Full Text PDF

---Pars plana vitrectomy in congenital X-linked retinoschisis: a scoping review.

Graefes Arch Clin Exp Ophthalmol

September 2025

Department of Ophthalmology, Emory University School of Medicine, 1365B Clifton Road, NE, Suite 2400, Atlanta, GA, 30322, USA.

Purpose: Congenital X-linked retinoschisis (XLRS) has limited treatment options. Gene augmentation via pars plana vitrectomy (PPV) and subretinal RS1 gene delivery is promising, yet it is unclear how PPV may impact outcomes. We explored literature to better understand PPV outcomes in XLRS.

View Article and Find Full Text PDF