Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Chiral mesoporous silica (SiO) with helical structure was synthesized by using anionic surfactants as template. Pre-prepared graphene oxide (GO) was then loaded onto SiO to synthesize composite carrier chial-meso-SiO@GO for the immobilization of laccase. The enzyme activity, thermostability, acid stability, and repeatability of the immobilized enzyme were significantly improved after immobilization. The chial-meso-SiO@GO-immobilized laccase was then used for the degradation of MXC in aqueous phase. The degradation conditions, including temperature, time, pH, MXC concentration, and the dose of immobilized enzyme for cellulosic hydrolysis, were optimized. The optimum conditions for degradation of methoxychlor were selected as pH 4.5, MXC concentration 30 mg/L, immobilized enzyme dose 0.1 g, the maximum MXC removal of over 85% and the maximum degradation rate of 50.75% were achieved after degradation time of six h at temperature of 45 °C. In addition, the immobilized cellulase was added into the immobilized laccase system to form chial-meso-SiO@GO-immobilized compound enzyme with the maximum MXC degradation rate of 59.58%, higher than that of 50.75% by immobilized laccase. An assessment was made for the effect of chial-meso-SiO@GO-immobilized compound enzyme on the degradation of MXC in soil phase. For three contaminated soils with MXC concentration of 25 mg/kg, 50 mg/kg, and 100 mg/kg, the MXC removals were 93.0%, 85.8%, and 65.1%, respectively. According to the GC-MS analyses, it was inferred that chial-meso-SiO@GO-immobilized compound enzyme had a different degradation route with that of chial-meso-SiO@GO-immobilized laccase. The hydrolysis by immobilized cellulase might attack at a weak location of the MXC molecule with its free radical OH and ultimately removed three chlorine atoms from MXC molecule, leading to generating small molecular amount of degradation product.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-019-05937-xDOI Listing

Publication Analysis

Top Keywords

immobilized enzyme
12
mxc concentration
12
chial-meso-sio@go-immobilized compound
12
compound enzyme
12
degradation
10
mxc
10
degradation methoxychlor
8
chial-meso-sio@go-immobilized laccase
8
degradation mxc
8
maximum mxc
8

Similar Publications

A sensitive electrochemical glucose biosensor using ZrO₂@CNTs nanocomposite was developed for real-time metabolism monitoring for athletes. The nanocomposite was prepared by a simple ultrasound-assisted technique, and the glucose oxidase (GOx) was covalently immobilized to improve the biorecognition ability. CNTs treated with acid served as a highly conductive framework, and ZrO₂ nanoparticles can provide structural stability and catalytic performance, thus showing synergistic enhancement of electron transfer kinetics and enzyme loading capacity.

View Article and Find Full Text PDF

Magnetic nano-crosslinked lipase aggregates: Preparation and catalytic synthesis of OPO.

Int J Biol Macromol

September 2025

Department of Pharmaceutical Engineering, School of Engineering, China Pharmaceutical University, Nanjing, 211198, China; Engineering Research Center for Smart Pharmaceutical Manufacturing Technologies, Ministry of Education, China Pharmaceutical University, Nanjing, 211198, China. Electronic addres

1,3-Dioleoyl-2-palmitoylglycerol (OPO) is crucial for infant nutrition; however, conventional immobilized lipase requires high-purity enzymes, which increases costs and limits industrial scalability. Herein, Rhizomucor miehei lipase (RML) was immobilized on surface-modified magnetic nanoparticles using cross-linked enzyme aggregates (CLEAs) technology to produce FeO@SiO@TPOAC@RML CLEAs. This approach combines the separation and immobilization of enzymes, allowing for the use of lower-purity lipase, which enhances its suitability for industrial-scale processes.

View Article and Find Full Text PDF

Programmable Dual-Phase Electrochemical Biosensor Combines Homogeneous CRISPR/Cas12a Activation with Interfacial Poly-G Signaling for miRNA-21 Detection.

Anal Chem

September 2025

Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological and Chemical Engineering, Jiaxing University, Jiaxing 314001, China.

Despite the promise of electrochemical biosensors in amplified nucleic acid diagnostics, existing high-sensitivity platforms often rely on a multilayer surface assembly and cascade amplification confined to the electrode interface. These stepwise strategies suffer from inefficient enzyme activity, poor mass transport, and inconsistent probe orientation, which compromise the amplification efficiency, reproducibility, and practical applicability. To address these limitations, we report a programmable dual-phase electrochemical biosensing system that decouples amplification from signal transduction.

View Article and Find Full Text PDF

Bioconversion of glycyrrhizin in a natural intensive sweetener by immobilized β-glucuronidase.

Food Res Int

November 2025

Department of Agriculture and Forest Sciences (DAFNE), Tuscia University, via S. Camillo de Lellis snc, 01100 Viterbo, Italy.

The demand for natural sweeteners as alternatives to sucrose is growing rapidly, driving research into enzymatic bioconversion methods for more efficient production. Glycyrrhizin (GL) is approximately 190 times sweeter than sucrose, but its excessive consumption has been linked to adverse health effects. Its hydrolysis yields glycyrrhetic acid 3-O-mono-β-D-glucuronide (GAMG), a compound nearly 1000 times sweeter than sucrose and with improved sensory and solubility properties.

View Article and Find Full Text PDF

Simulations in three dimensions and time provide guidance on implantable, electroenzymatic glutamate sensor design; relative placement in planar sensor arrays; feasibility of sensing synaptic release events; and interpretation of sensor data. Electroenzymatic sensors based on the immobilization of oxidases on microelectrodes have proven valuable for the monitoring of neurotransmitter signaling in deep brain structures; however, the complex extracellular milieu featuring slow diffusive mass transport makes rational sensor design and data interpretation challenging. Simulations show that miniaturization of the disk-shaped device size below a radius of ∼25 μm improves sensitivity, spatial resolution, and the accuracy of glutamate concentration measurements based on calibration factors determined .

View Article and Find Full Text PDF