Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Thyroglobulin (Tg) assessment in the needle washout after fine-needle aspiration biopsy (FNAB) of a suspicious neck lymph node (LN) is known to improve the diagnostic accuracy in patients with papillary thyroid cancer (PTC). However, there is still controversy on the best diagnostic cut-off levels for FNAB-Tg and whether thyroglobulin antibody (TgAb) positivity affects FNAB-Tg. The objectives of this study were to determine (i) the diagnostic power of different cut-offs for FNAB-Tg and (ii) if serum TgAb(+) negatively affects the FNAB-Tg evaluation.

Methods: This was a retrospective cohort study analyzing PTC patients with suspicious neck LNs, in a university hospital setting, from October 2009 to October 2013. In total, 103 patients with PTC (226 LNs) undergoing ultrasound-guided FNAB for LNs were included. Cytology and FNAB-Tg levels were compared in reference to LN histopathology and the effect of TgAb(+) on FNAB-Tg levels was evaluated.

Results: The diagnostic accuracies of FNAB-Tg cut-off of 1 and 10 ng/mL were 94.1% and 88.2%, respectively. Raising the cut-off from 1 to 10 ng/mL led to decreased sensitivity rates (91.9% vs. 83.9%). The receiver operating characteristic curve analysis demonstrated that the best FNAB-Tg cut-off was 1.2 ng/mL. There were no LNs with an FNAB-Tg ≥ 10 ng/mL that turned out to be cytologically or histopathologically benign. FNAB-Tg levels of the histopathologically malignant LNs were similar between TgAb (+) and TgAb (-) patients (p = 0.546). Serum Tg predicted FNAB-Tg levels above 1 ng/mL (p = 0.002) and FNAB-Tg predicted malignant histopathology (p = 0.004), both independently of the TgAb status of the patient.

Conclusions: FNAB-Tg ≥ 1 ng/mL has a superior diagnostic power, irrespective of TgAb (+), in PTC patients with suspected LN involvement.

Download full-text PDF

Source
http://dx.doi.org/10.3109/07435800.2016.1141936DOI Listing

Publication Analysis

Top Keywords

fnab-tg levels
16
fnab-tg
13
cut-off ng/ml
12
lymph node
8
fine-needle aspiration
8
papillary thyroid
8
thyroid cancer
8
suspicious neck
8
diagnostic power
8
ptc patients
8

Similar Publications

Background: Both fine-needle aspiration biopsy (FNAB) and frozen section (FS) examination are reliable methods for assessing cervical lymph node (level II-V) metastasis (LNM) in papillary thyroid carcinoma (PTC). Our goal was to compare the diagnostic accuracy of FNAB and FS in clinically positive neck (cN+) PTC patients.

Methods: Altogether, 264 lymph node samples from 220 patients were prospectively enrolled.

View Article and Find Full Text PDF

Objectives: To analyze the diagnostic benefit of fine needle aspiration biopsy cytology (FNAB-C) and core needle biopsy tissue (CNB-T) with the addition of thyroglobulin (Tg) in the washout of the needle or BRAF V600E mutation assessment in assessing cervical lymph node metastasis (LNM) in papillary thyroid carcinoma.

Materials And Methods: A total of 186 lymph nodes were punctured by fine or core needle. The diagnostic performance of FNAB-C and CNB-T with Tg in the washout or BRAF V600E mutation assessment was compared.

View Article and Find Full Text PDF

Thyroglobulin Determination in Fine Needle Aspiration Biopsy Washout of Suspicious Lymph Nodes in Thyroid Carcinoma Follow up.

Endocr Metab Immune Disord Drug Targets

June 2018

Interdisciplinary Department of Medicine-Section of Internal Medicine, Geriatrics, Endocrinology and Rare Diseases, University of Bari "Aldo Moro", Bari. Italy.

Background: Differentiated thyroid carcinomas (DTCs) account for about 1% of all human malignancies. Cervical lymph nodes metastases and recurrences in the thyroid bed frequently occur. Furthermore, about 10-15% of patients develop distant metastases.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effectiveness of fine-needle aspiration biopsy with thyroglobulin measurement (FNAB-Tg) for diagnosing cervical lymph node metastases in patients with papillary thyroid cancer prior to surgery.
  • Ultrasonography-guided FNAB was performed on 92 patients, revealing that 67 out of 105 lymph nodes had metastasis post-surgery.
  • FNAB-Tg demonstrated high sensitivity (100%) and overall accuracy (95.2%), making it a valuable diagnostic tool in this context.
View Article and Find Full Text PDF

Purpose: Thyroglobulin (Tg) assessment in the needle washout after fine-needle aspiration biopsy (FNAB) of a suspicious neck lymph node (LN) is known to improve the diagnostic accuracy in patients with papillary thyroid cancer (PTC). However, there is still controversy on the best diagnostic cut-off levels for FNAB-Tg and whether thyroglobulin antibody (TgAb) positivity affects FNAB-Tg. The objectives of this study were to determine (i) the diagnostic power of different cut-offs for FNAB-Tg and (ii) if serum TgAb(+) negatively affects the FNAB-Tg evaluation.

View Article and Find Full Text PDF