State of the art in the determination of trace elements in seawater: a worldwide proficiency test.

Anal Bioanal Chem

European Commission, Directorate General Joint Research Centre, Institute for Reference Materials and Measurements, Retieseweg 111, 2440, Geel, Belgium.

Published: May 2016


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This manuscript presents the results of the International Measurement Evaluation Programme 40 (IMEP-40) study, a proficiency test (PT) which was organised to assess the worldwide performance of laboratories for the determination of trace elements in seawater. This PT supports the implementation of the European Union Water Framework Directive 2000/60/EC, which aims at achieving a long-term high level protection of the aquatic environment, covering lakes, ground water and coastal waters. Forty-six participants reported results. The test item was seawater containing the trace elements As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Se and Zn. The trace elements in the test item were present in very low concentrations to mimic natural levels. The results of the participants were rated with z and zeta (ζ) scores in accordance with ISO 13528 and ISO 17043. The standard deviation for proficiency assessment, σ̂, was set at 25% of the respective assigned values for the 12 measured elements based on previous experience with similar PTs. The low levels of the trace elements combined with the high salt concentration of the seawater made the measurements challenging. Many laboratories were unable to detect or quantify the elements and reported "lower than X" values. The percentage of satisfactory performances (expressed as z scores) ranged from 41% (Cr, Fe) to 86% (Mo). The PT study showed that the use of proper standard methods, like ISO 17294-2, and sensitive techniques, like inductively coupled plasma mass spectrometry (ICP-MS), contributed to performing well in this PT round.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4830889PMC
http://dx.doi.org/10.1007/s00216-016-9390-6DOI Listing

Publication Analysis

Top Keywords

trace elements
20
determination trace
8
elements seawater
8
proficiency test
8
test item
8
elements
7
trace
5
state art
4
art determination
4
seawater
4

Similar Publications

Surveillance monitoring of shallow groundwater revealed that redox conditions can vary on a small scale. Therefore, the aim of this study was to categorize redox conditions in the groundwater of Lower Saxony, Germany, and to analyze the spatial distribution and trends of parameters related to redox conditions during surveillance monitoring from 1957 to 2015 in Lower Saxony, Germany. Methodically, trends were considered by applying the Mann-Kendall test and redox conditions of groundwater were classified according to the scheme of Jurgens et al.

View Article and Find Full Text PDF

Ischemic stroke (IS) has high morbidity/mortality with limited treatments. This study screened core copper homeostasis-related genes in IS and validated their function as precise intervention targets. Human IS gene chip data were retrieved from GEO, and copper homeostasis genes from multiple databases.

View Article and Find Full Text PDF

Time-resolved data acquisition is crucial for compositional analysis using Laser-Induced Breakdown Spectroscopy (LIBS). It can be managed by adjusting the delay time and gate width of the spectrometer. This study describes the compositional analysis of molybdenum (Mo) ore utilizing charge coupled device (CCD) and intensified charge-coupled device (ICCD) based LIBS systems.

View Article and Find Full Text PDF

Objective: This study aimed to reexplore minimum iodine excretion and to build a dietary iodine recommendation for Chinese adults using the obligatory iodine loss hypothesis.

Methods: Data from 171 Chinese adults (19-21 years old) were collected and analyzed based on three balance studies in Shenzhen, Yinchuan, and Changzhi. The single exponential equation was accordingly used to simulate the trajectory of 24 h urinary iodine excretion as the low iodine experimental diets offered (iodine intake: 11-26 μg/day) and to further deduce the dietary reference intakes (DRIs) for iodine, including estimated average requirement (EAR) and recommended nutrient intake (RNI).

View Article and Find Full Text PDF

Three-dimensional printing (3DP) technology enables the flexible fabrication of integrated monolithic microextraction chips for high-throughput sample pretreatment. Meanwhile, the extraction performance of 3DP-based channels is largely limited by printer resolution and the commercially available printing materials. In this work, a 3DP array monolithic microextraction chip (AMC) was fabricated by integrating 26-array helical monolithic microextraction channels for sample pretreatment and 52-array gas valves for fluid control.