98%
921
2 minutes
20
Cost-effective pharmaceutical drug discovery depends on increasing assay throughput while reducing reagent needs. To this end, we are developing an ultrasensitive, fluorescence-based platform that incorporates a nano/micro-fluidic chip with an array of closely spaced channels for parallelized optical readout of single-molecule assays. Here we describe the use of direct femtosecond laser machining to fabricate several hundred closely spaced channels on the surfaces of fused silica substrates. The channels are sealed by bonding to a microscope cover slip spin-coated with a thin film of poly(dimethylsiloxane). Single-molecule detection experiments are conducted using a custom-built, wide-field microscope. The array of channels is epi-illuminated by a line-generating red diode laser, resulting in a line focus just a few microns thick across a 500 micron field of view. A dilute aqueous solution of fluorescently labeled biomolecules is loaded into the device and fluorescence is detected with an electron-multiplying CCD camera, allowing acquisition rates up to 7 kHz for each microchannel. Matched digital filtering based on experimental parameters is used to perform an initial, rapid assessment of detected fluorescence. More detailed analysis is obtained through fluorescence correlation spectroscopy. Simulated fluorescence data is shown to agree well with experimental values.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4178987 | PMC |
http://dx.doi.org/10.3390/s140815400 | DOI Listing |
ACS Appl Mater Interfaces
September 2025
National Energy Metal Resources and New Materials Key Laboratory Engineering Research Center of the Ministry of Education for Advanced Battery Materials Hunan Provincial Key Laboratory of Nonferrous Value-Added Metallurgy School of Metallurgy and Environment, Central South University, Changsha 41008
Hard carbon (HC), recognized as the most promising anode material for sodium-ion batteries (SIBs), exhibits multiple forms of sodium storage (adsorption on graphitic layers, insertion between graphitic sheets, and filling in closed pores). Low initial coulombic efficiency (ICE) and low plateau region capacity are the main issues with HC, and it is necessary to understand the evolution laws of graphitic layers and closed pores. Here, we regulate the structure of graphitic layers by deliberately changing the oxygen content in HC materials and reveal the mechanism of formation of closed pores.
View Article and Find Full Text PDFImaging Neurosci (Camb)
September 2025
Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin Center for Advanced Neuroimaging, Berlin, Germany.
In multivariate pattern analysis (MVPA) for functional magnetic resonance imaging (fMRI) signals, trial-wise response amplitudes are sometimes estimated using a general linear model (GLM) with one onset regressor for each trial. When using rapid event-related designs with trials closely spaced in time, those estimates can be highly correlated due to the temporally smoothed shape of the hemodynamic response function. In previous work (Soch et al.
View Article and Find Full Text PDFSolid state nanopores have emerged as powerful tools for single-molecule sensing, yet the rapid uncontrolled translocation of the molecule through the pore remains a key limitation. We have previously demonstrated that an active dual-nanopore system, consisting of two closely spaced pores operated via feedback controlled biasing, shows promise in achieving controlled, slowed-down translocation. Translocation control is achieved via capturing the DNA in a special tug-of-war configuration, whereby opposing electrophoretic forces at each pore are applied to a DNA molecule co-captured at the two pores.
View Article and Find Full Text PDFJ Back Musculoskelet Rehabil
September 2025
Institute of Physiotherapy, Srinivas University City campus Pandeshwar, Mangaluru, Karnataka, India.
BackgroundThe closed kinetic chain upper extremity stability test (CKCUEST) is widely used to assess shoulder stability. The modified CKCUEST (mCKCUEST) incorporates height-normalized hand spacing (50%) to account for individual anthropometric variations and improve biomechanical validity.ObjectiveTo establish normative reference values for mCKCUEST performance in healthy Indian adults and to define diagnostic thresholds and performance phenotypes using percentile classification, ROC analysis, and clustering techniques.
View Article and Find Full Text PDFJ Phys Chem A
September 2025
Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.
The rotational spectra and analysis of the two lowest-energy vibrationally excited states, ν (A', 126 cm, MP2) and ν (A″, 133 cm, MP2), of -1-cyano-1,3-butadiene from 130 to 375 GHz is presented. The state symmetries allow and type Coriolis coupling, the effects of which are observed due to the close energy spacing of these states. A combined total of 6744 transitions were modeled (σ < 60 kHz) with a partial-octic two-state A-reduced Hamiltonian including eight coupling parameters (, , , , , , , and ).
View Article and Find Full Text PDF