Positioning of the ablation catheter in total endoscopic ablation.

Interact Cardiovasc Thorac Surg

Department of Cardiothoracic and Vascular Surgery, Örebro University Hospital, Örebro, Sweden.

Published: January 2014


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Minimally invasive ablation of atrial fibrillation is an option in patients not suitable for or refractory to catheter ablation. Total endoscopic ablation can be performed via a monolateral approach, whereby a left atrial box lesion is created. If the ablation is introduced from the right side, the positioning of the ablation catheter on the partly hidden left pulmonary veins is of vital importance. Using thoracoscopy in combination with multiplane transoesophageal echocardiography, the anatomical position of the ablation catheter can be established. Our experience in over 60 procedures has confirmed this to be a safe technique of total endoscopic ablation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3867043PMC
http://dx.doi.org/10.1093/icvts/ivt433DOI Listing

Publication Analysis

Top Keywords

ablation catheter
12
total endoscopic
12
endoscopic ablation
12
positioning ablation
8
ablation
8
catheter
4
catheter total
4
ablation minimally
4
minimally invasive
4
invasive ablation
4

Similar Publications

Background: The effectiveness of ethanol infusion of the vein of Marshall (EIVOM) for persistent atrial fibrillation (AF) in patients with mitral valve replacement (MVR) remains to be determined.

Objectives: This study investigated the effectiveness and safety of EIVOM in catheter ablation of persistent AF in patients with MVR.

Methods: This is a retrospective case-control study.

View Article and Find Full Text PDF

Background: Catheter ablation of scar-related interatrial septal atrial tachycardias (IAS-ATs) is challenging and can be refractory to conventional unipolar radiofrequency catheter ablation (RFCA).

Aim: This multicenter study investigated the safety and efficacy of bipolar radiofrequency catheter ablation (Bi-RFCA) in patients with IAS-AT refractory to conventional unipolar RFCA.

Methods: Consecutive patients with scar-related IAS-AT refractory to conventional unipolar RFA across three electrophysiological centers were included in the study.

View Article and Find Full Text PDF

A Fluoroless Workflow Using Transoesophageal Echocardiography for Catheter Ablation of Atrial Fibrillation Using Pulsed Field Ablation.

Heart Lung Circ

September 2025

Cardiology Department, Westmead Hospital, Sydney, NSW, Australia; Westmead Applied Research Centre, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia. Electronic address:

Background: Catheter ablations are increasingly performed with zero or minimal fluoroscopy, enabled by ultrasound imaging and electro-anatomical mapping. Pulsed field ablation (PFA) using Farawave has been dependent on fluoroscopic assessment of catheter conformation and contact. We aimed to demonstrate the feasibility of a PFA workflow for pulmonary vein isolation (PVI) and extrapulmonary ablation.

View Article and Find Full Text PDF

Introduction: Atrial fibrillation (AF) is the most common cardiac arrhythmia, significantly affecting patients' quality of life (QoL) and increasing the risk of complications such as heart failure, stroke and dementia. In addition to the physical burden, psychological distress, including depression and anxiety, is prevalent among patients with AF and can exacerbate clinical symptoms and worsen overall well-being. While radiofrequency ablation (RFA) is widely used for rhythm control in AF, its long-term effects on both physical and psychological outcomes, including symptom severity, anxiety, depression and QoL, remain underexplored.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF), affects around 2% of the global population and is projected to rise over the next 50 years. Catheter ablation (CA) is the primary treatment for symptomatic AF resistant to drug therapy. Despite its widespread use, CA has a failure rate of 20% to 50%, often requiring repeat procedures, due to significant long-term recurrence rates.

View Article and Find Full Text PDF