Article Abstract

Background: Hyperventilation and consequent reduction of ventilation (VE) efficiency are frequently observed during exercise in heart failure (HF) patients, resulting in an increased slope of VE/carbon dioxide (VE/Vco(2)) relationship. The latter is an independent predictor of HF prognosis. beta-Blockers improve the prognosis of HF patients. We evaluated the effect on the efficiency of VE of a beta(1)-beta(2) unselective (carvedilol) versus a beta(1) selective (bisoprolol) beta-blocker.

Methods: We analyzed consecutive maximal cardiopulmonary exercise tests performed on 572 clinically stable HF patients (New York Heart Association class I-III, left ventricle ejection fraction < or =50%) categorized in 3 groups: 81 were not treated with beta-blocker, 304 were treated with carvedilol, and 187 were treated with bisoprolol. Clinical conditions were similar.

Results: The VE/Vco(2) slope was lower in carvedilol- compared with bisoprolol-treated patients (29.7 +/- 0.4 vs 31.6 +/- 0.5, P = .023, peak oxygen consumption adjusted) and with patients not receiving beta-blockers (31.6 +/- 0.7, P = .036). Maximum end-tidal CO(2) pressure during the isocapnic buffering period was higher in patients treated with carvedilol (39.0 +/- 0.3 mm Hg) than with bisoprolol (37.2 +/- 0.4 mm Hg, P < .001) and in patients not receiving beta-blockers (37.2 +/- 0.5 mm Hg, P = .001).

Conclusions: Reduction of hyperventilation, with improvement of VE efficiency during exercise (reduction of VE/Vco(2) slope and increase of maximum end-tidal CO(2) pressure), is specific to carvedilol (beta(1)-beta(2) unselective blocker) and not to bisoprolol (beta(1)-selective blocker).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ahj.2010.03.034DOI Listing

Publication Analysis

Top Keywords

ventilation efficiency
8
heart failure
8
beta1-beta2 unselective
8
treated carvedilol
8
ve/vco2 slope
8
316 +/-
8
patients receiving
8
receiving beta-blockers
8
maximum end-tidal
8
end-tidal co2
8

Similar Publications

Background: Admission to shared hospital rooms are a risk factor of healthcare-associated (HA) SARS-CoV-2. Quantifying the impact of engineering controls such as ventilation and filtration is essential to informing resource utilization and infection prevention guidelines.

Methods: Multicenter test-negative study of patients exposed to SARS-CoV-2 in shared rooms across five hospitals between January and October, 2022.

View Article and Find Full Text PDF

Background: Procalcitonin (PCT) is used in the diagnosis of sepsis. Its capability as a prognostic marker is unclear. The association between PCT and paediatric intensive care unit (PICU) outcomes has not been investigated in the South African setting.

View Article and Find Full Text PDF

Hospital operating theatre suites are a particularly resource- and energy-intensive component of the health sector. Reducing their carbon footprint presents a significant challenge due to the necessity of maintaining patient safety. In this paper, we apply a multidisciplinary methodology to investigate and assess various strategies aimed at reducing the carbon footprint in hospital theatres.

View Article and Find Full Text PDF

Objective: Telehealth preoperative evaluations have been shown to improve access to care, reduce appointment cancellations, and support efficient procedural planning across multiple surgical subspecialties. However, few studies have assessed the safety and efficacy in patients undergoing elective cardiac surgery.

Methods: We conducted a retrospective multi-institutional cohort study comparing procedural and postoperative outcomes for patients who had telehealth versus in-person preoperative evaluations for elective cardiac surgery between March 1, 2020, and March 1, 2021.

View Article and Find Full Text PDF

Multifunctional Photoactive Janus Nanofibrous Membranes for Unidirectional Water Transport and Remediation of Airborne Pathogens and Pollutants.

ACS Nano

September 2025

State Key Laboratory of Materials-Oriented Chemical Engineering, National Engineering Research Center for Special Separation Membrane, Nanjing Tech University, Nanjing 210009, China.

Airborne pathogens and pollution control typically necessitate multiple membranes, each specializing in efficient aerosol filtration, moisture regulation, or antimicrobial protection. Integrating all these functions into a single membrane is highly advantageous but remains inherently challenging due to material incompatibility and inevitable performance trade-offs. Here, we present a photoactive Janus nanofibrous membrane for highly efficient air purification, engineered via sequential electrospinning.

View Article and Find Full Text PDF