Left ventricular assist devices (LVADs), such as the HeartMate 3 (HM3), are a treatment option for advanced heart failure (HF). Non-invasive monitoring of heart-pump interaction is crucial but relies on estimated parameters only. Despite the widespread clinical utilization of HM3 estimated flow rate (Q) and pulsatility index (PI) their accuracy was not yet quantified.
View Article and Find Full Text PDFIn magnetically levitated rotodynamic blood pumps (RPBs), the impeller position depends on a balance of electromagnetic and fluid dynamic forces. The aim of this study was to describe the impeller position of the HeartMate 3 over a wide range of operating conditions and assess its potential impact on hemocompatibility. Three-dimensional impeller positions were measured using a transparent HeartMate 3 pump casing, laser distance measurements, and a high-speed camera.
View Article and Find Full Text PDFBackground: Left ventricular assist device (LVAD) malposition has been linked to hemocompatibility-related adverse events (HRAEs). This study aimed to identify preoperative anatomical landmarks and postoperative pump position, associated with HRAEs during LVAD support.
Methods: Pre- and postoperative chest X-ray measures (≤14 days pre-implantation, first postoperative standing, 6, 12, 18, and 24 months post-implantation) were analyzed for their association with HRAEs over 24 months in 33 HeartMate 3 (HM3) patients (15.
Introduction: The influence of vagus nerve stimulation (VNS) parameters on provoked cardiac effects in different levels of cardiac innervation is not well understood yet. This study examines the effects of VNS on heart rate (HR) modulation across a spectrum of cardiac innervation states, providing data for the potential optimization of VNS in cardiac therapies.
Materials And Methods: Utilizing previously published data from VNS experiments on six sheep with intact innervation, and data of additional experiments in five rabbits post bilateral rostral vagotomy, and four isolated rabbit hearts with additionally removed sympathetic influences, the study explored the impact of diverse VNS parameters on HR.
The cardiac responses to vagus nerve stimulation (VNS) are still not fully understood, partly due to uncontrollable confounders in the in-vivo experimental condition. Therefore, an ex-vivo Langendorff-perfused rabbit heart with intact vagal innervation is proposed to study VNS in absence of cofounding anesthetic or autonomic influences. The feasibility to evoke chronotropic responses through electrical stimulation ex-vivo was studied in innervated isolated rabbit hearts (n = 6).
View Article and Find Full Text PDFIntroduction: Transcatheter aortic valve implantation (TAVI) has become an alternative to surgical replacement of the aortic valve elderly patients. However, TAVI patients may suffer from paravalvular leaks (PVL). Detecting and grading is usually done by echocardiography, but is limited by resolution, 2D visualization and operator dependency.
View Article and Find Full Text PDFAtrial fibrillation (AF) is a common comorbidity in left ventricular assist device (LVAD) patients and has been identified as a risk factor for thromboembolic stroke. Blood stagnation within the left atrial appendage (LAA) is considered a possible major source of thrombosis and clinical studies have shown reduced thromboembolic risk after LAA occlusion (LAAO). Therefore, this study aims to investigate the effect of LAAO on thrombosis-related parameters using patient-specific simulations.
View Article and Find Full Text PDFBackground: Contemporary Left Ventricular Assist Devices (LVADs) mainly operate at a constant speed, only insufficiently adapting to changes in patient demand. Automatic physiological speed control promises tighter integration of the LVAD into patient physiology, increasing the level of support during activity and decreasing support when it is excessive.
Methods: A sensorless modular control algorithm was developed for a centrifugal LVAD (HVAD, Medtronic plc, MN, USA).
Right heart failure (RHF) is a severe complication after left ventricular assist device (LVAD) implantation. The aim of this study was to analyze the incidence, risk factors, and biomarkers for late RHF including the possible superiority of the device and implantation method. This retrospective, single-center study included patients who underwent LVAD implantation between 2014 and 2018.
View Article and Find Full Text PDFBackground: A relation between the left ventricular assist device inflow cannula (IC) malposition and pump thrombus has been reported. This study aimed to investigate if the pump position, derived from chest X-rays in HeartMate 3 (HM3) patients, correlates with neurological dysfunction (ND), ischemic stroke (IS), hemorrhagic stroke (HS) and survival.
Methods: This analysis was performed on routinely acquired X-rays of 42 patients implanted with a HM3 between 2014 and 2017.
Simulations of the ventricular flow patterns during left ventricular assist device (LVAD) support are mainly performed with idealized cylindrical inflow, neglecting the influence of the atrial vortex. In this study, the influence of the left atrium (LA) on the intra-ventricular flow was investigated via Computational Fluid Dynamics (CFD) simulations. Ventricular flow was simulated by a combined Eulerian (carrier flow)/Lagrangian (particles) approach taking into account either the LA or a cylindrical inflow section to mimic a fully support condition.
View Article and Find Full Text PDFInt J Artif Organs
December 2021
Malpositioning of left ventricular assist devices (LVAD) is a risk factor for thrombosis, but its identification from clinical imaging remains challenging. X-rays and CT scans were analyzed and parameters identified that correlated to pump thrombosis. Retrospective imaging data of patients ( = 115) with HeartmateII (HMII) or HVAD were analyzed in two groups (pump-thrombosis PT, = 15 vs matched control group NT, = 15) using routine X-rays and CT scans.
View Article and Find Full Text PDFLeft ventricular assist devices inherently alter the intraventricular flow field and create areas of blood stasis with potential thrombus formation. The Lavare cycle of the Medtronic HeartWare HVAD was designed to improve ventricular washout. This study aims to evaluate its effects on ventricular washout in a pulsatile in vitro setting with a focus on the timing of pump speed changes.
View Article and Find Full Text PDFThe use of left ventricular assist devices (LVADs) as a treatment method for heart failure patients has been steadily increasing; however, pathological studies showed presence of thrombi around the HeartWare ventricular assist device inflow cannula (IC) in more than 95% of patients after device explantation. Flow fields around the IC might trigger thrombus formation and require further investigation. In this study flow dynamics parameters were evaluated for different patient geometries using computational fluid dynamics (CFD) simulations.
View Article and Find Full Text PDFIntraventricular flow patterns during left ventricular assist device support have been investigated via computational fluid dynamics by several groups. Based on such simulations, specific parameters for thrombus formation risk analysis have been developed. However, computational fluid dynamic simulations of complex flow configurations require proper validation by experiments.
View Article and Find Full Text PDFThe previously more frequently implanted pulsatile blood pumps (PBPs) showed higher recovery rates than the currently preferred rotary blood pumps (RBPs), with unclear causality. The aim of this study was to comparatively assess the capability of PBPs and RPBs to unload the left ventricle and maintain cardiac energetics as a possible implication for recovery. An RBP and a heartbeat synchronized PBP were alternately connected to isolated porcine hearts.
View Article and Find Full Text PDFIn heart failure therapy, minimally invasive devices (transcatheter valves, catheter-based cannulas or pumps) are increasingly used. The interaction with the valve is of special importance as valve damage, backflow, and thrombus formation are known complications. Therefore, the aim of this in vitro study was to characterize the forces acting on different sized transvalvular cannulas at various transvalvular pressures for four different valves.
View Article and Find Full Text PDFEur J Cardiothorac Surg
November 2016
Objectives: Ventricular blood stasis is a concern for continuous flow mechanical support devices and might contribute to the formation of thromboembolic events. The HeartWare® Ventricular Assist System (HVAD®) is equipped with the Lavare™ cycle that is a periodic speed modulation feature designed to alter flow patterns within the left ventricle and reduce areas of potential blood stasis. Here, we report in vitro and clinical findings on the effects of the Lavare cycle.
View Article and Find Full Text PDFNew left ventricular assist devices (LVADs) offer both important advantages and potential hazards. VAD development requires better and expeditious ways to identify these advantages and hazards. We validated in an isolated working heart the hemodynamic performance of an intraventricular LVAD and investigated how its outflow cannula interacted with the aortic valve.
View Article and Find Full Text PDFEur J Cardiothorac Surg
September 2014
Objectives: The aim of the study was to simulate the effect of different bicuspid aortic valve configurations on the dynamic pressure distribution in the ascending aorta.
Methods: Aortic specimens were harvested from adult domestic pigs. In Group 1, bicuspidalization was created by a running suture between the left and the right coronary leaflets (n = 6) and in Group 2 by a running suture between the left and the non-coronary leaflets (n = 6).
Int J Artif Organs
December 2013
Background: Currently, the interaction between rotary blood pumps (RBP) and the heart is investigated in silico, in vitro, and in animal models. Isolated and defined changes in hemodynamic parameters are unattainable in animal models, while the heart-pump interaction in its whole complexity cannot be modeled in vitro or in silico.
Aim: The aim of this work was to develop an isolated heart setup to provide a realistic heart-pump interface with the possibility of easily adjusting hemodynamic parameters.
J Thorac Cardiovasc Surg
December 2013
Background: Median sternotomy is the access of choice in cardiac surgery. Sternal retractors exert significant forces on the thoracic cage and might cause considerable damage. The aim of this study was to determine the effects of retractor shape on local force distribution to obtain criteria for retractor design.
View Article and Find Full Text PDFInt J Artif Organs
October 2013
Purpose: Investigations of the circulatory system in vitro use mock circuits that require valves to mimic the cardiac situation. Whereas mechanical valves increase water hammer effects due to inherent stiffness and do not allow the use of pressure lines or catheters, bioprosthetic valves are expensive and of limited durability in test fluids. Therefore, we developed a cheap, fast, alternative method to mount valves obtained from the slaughterhouse in mock circuits.
View Article and Find Full Text PDFInt J Artif Organs
February 2013
Aim: Transparent hollow models are needed to visualize and quantify flow in various applications. To obtain the final transparent model, an intermediate molding of the fluid space with an easily removable material is required. Currently used materials to produce this intermediate molding have limitations: toxicity, cost, and a tendency to penetrate the final model, thereby degrading its transparency.
View Article and Find Full Text PDF